Home › General › SPECIFICATIONS › 1NZ-FXE COOLING › from 2017.06
RM2170E _V1 General _057001 SPECIFICATIONS _0277860 1NZ-FXE COOLING F

SPECIFICATIONS  1NZ-FXE COOLING  SERVICE DATA  


Exhaust Heat Recirculation System
Condition Rod Operation
Cold (below approx. 71°C (160°F)) → Warmed up (approx. 80°C (176°F) or more) Rod gradually extends smoothly as the temperature rises

Temperature Switch
Condition Specified Condition
Approximately 20°C (68°F) 2.32 to 2.59 kΩ
Approximately 80°C (176°F) 0.310 to 0.326 kΩ

Thermostat
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 0.8 mm (0.315 in.) or more at 95°C (203°F)

Cooling Fan Motor
Item Condition Specified Condition
Cooling fan motor 20°C (68°F) at 12 V 12.2 to 15.7 A

Cooling Fan Relay
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 Below 1 Ω

Water Filler Cap Sub-assembly
Item Tester Connection Specified Condition
Water filler cap sub-assembly for brand-new cap 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
for used cap 78.5 kPa (0.8 kgf/cm2, 11.4 psi)

Coolant
Capacity Classification
w/ Exhaust Heat Recirculation System:
5.2 liters (5.5 US qts, 4.6 lmp. qts)
w/o Exhaust Heat Recirculation System:
4.5 liters (4.8 US qts, 4 lmp. qts)
TOYOTA vehicles are filled with TOYOTA SLLC at the factory. In order to avoid damage to the engine cooling system and other technical problems, only use TOYOTA SLLC or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).