When the power switch is on (IG), the power window regulator motor assembly (for rear RH door) is operated by the power window regulator switch assembly (for rear RH door).
for LHD
for RHD
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the power window regulator switch assembly (for rear RH door) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K1-3 (B) - Body ground | Power switch on (IG) | 11 to 14 V |
OK
NG
| *a | Component without harness connected
(Power Window Regulator Switch Assembly (for Rear RH Door)) |
Remove the power window regulator switch assembly (for rear RH door).
Click hereVehicle Exterior>WINDOW / GLASS>REAR POWER WINDOW SWITCH>REMOVAL
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 (D) - 2 (SD) | UP | Below 1 Ω |
| 3 (B) - 4 (U) | Below 1 Ω | |
| 1 (D) - 2 (SD) | off | Below 1 Ω |
| 4 (U) - 5 (SU) | Below 1 Ω | |
| 4 (U) - 5 (SU) | DOWN | Below 1 Ω |
| 1 (D) - 3 (B) | Below 1 Ω |
OK
NG
Disconnect the power window regulator motor assembly (for rear RH door) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K1-4 (U) - K2-1 (U) | Always | Below 1 Ω |
| K1-1 (D) - K2-2 (D) | Always | Below 1 Ω |
| K1-4 (U) - Body ground | Always | 10 kΩ or higher |
| K1-1 (D) - Body ground | Always | 10 kΩ or higher |
OK
NG
| *A | for LHD and w/o Canister Pump Module |
| *B | for LHD and w/ Canister Pump Module |
| *C | for RHD |
| *a | Component without harness connected
(Power Window Regulator Master Switch Assembly) |
Remove the power window regulator master switch assembly.
Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>REMOVAL
Measure the resistance when the switch is operated according to the value(s) in the table below.
for LHD
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 6 (B) - 10 (U)*1
7 (B) - 15 (U)*2 |
UP | Below 1 Ω |
| 1 (E) - 18 (D)*1
1 (E) - 16 (D)*2 |
Below 1 Ω | |
| 1 (E) - 10 (U)*1
1 (E) - 15 (U)*2 |
off | Below 1 Ω |
| 1 (E) - 18 (D)*1
1 (E) - 16 (D)*2 |
Below 1 Ω | |
| 6 (B) - 18 (D)*1
7 (B) - 16 (D)*2 |
DOWN | Below 1 Ω |
| 1 (E) - 10 (U)*1
1 (E) - 15 (U)*2 |
Below 1 Ω |
*1: w/o Canister Pump Module
*2: w/ Canister Pump Module
for RHD
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 6 (B) - 16 (U) | UP | Below 1 Ω |
| 9 (E) - 15 (D) | Below 1 Ω | |
| 9 (E) - 16 (U) | off | Below 1 Ω |
| 9 (E) - 15 (D) | Below 1 Ω | |
| 6 (B) - 15 (D) | DOWN | Below 1 Ω |
| 9 (E) - 16 (U) | Below 1 Ω |
OK
NG
Measure the resistance according to the value(s) in the table below.
for LHD
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J1-10 (U) - K1-5 (SU)*1
J1-15 (U) - K1-5 (SU)*2 |
Always | Below 1 Ω |
| J1-18 (D) - K1-2 (SD)*1
J1-16 (D) - K1-2 (SD)*2 |
Always | Below 1 Ω |
| J1-10 (U) - Body ground*1
J1-15 (U) - Body ground*2 |
Always | 10 kΩ or higher |
| J1-18 (D) - Body ground*1
J1-16 (D) - Body ground*2 |
Always | 10 kΩ or higher |
for RHD
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H1-16 (U) - K1-5 (SU) | Always | Below 1 Ω |
| H1-15 (D) - K1-2 (SD) | Always | Below 1 Ω |
| H1-16 (U) - Body ground | Always | 10 kΩ or higher |
| H1-15 (D) - Body ground | Always | 10 kΩ or higher |
OK
NG