Home › Vehicle Exterior › LIGHTING (EXT) › RELAY › from 2017.06
RM2170E _59 Vehicle Exterior _057049 LIGHTING (EXT) _0278204 RELAY G

LIGHTING (EXT)  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85916P 1.INSPECT H-LP RELAY

E209495C36
0.156,0.135 0.469,0.333 0.313,0.198 10 false *a
*a Component without harness connected
(H-LP Relay)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the H-LP relay.


Hide 85926 2.INSPECT DIM RELAY

E209495C36
0.156,0.135 0.469,0.333 0.313,0.198 10 false *a
*a Component without harness connected
(DIM Relay)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the DIM relay.


Hide 81550T 3.INSPECT BKUP LP RELAY

E222294C84
1.073,0.958 1.302,0.49 1.302,0.49 1.438,0.49 false 1.063,1.333 1.146,1.75 1.146,1.75 1.344,1.75 false 0.802,1.01 0.938,0.49 0.938,0.49 1.063,0.49 false 0.563,1.281 0.635,1.76 0.635,1.76 0.823,1.76 false 1.458,0.406 1.563,0.563 0.104,0.156 10 false 1 1.375,1.667 1.479,1.823 0.104,0.156 10 false 2 1.094,0.396 1.198,0.552 0.104,0.156 10 false 5 0.844,1.667 0.948,1.823 0.104,0.156 10 false 3 0.198,0.188 0.51,0.385 0.313,0.198 10 false *a
*a Component without harness connected
(BKUP LP Relay)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the BKUP LP relay.


Hide 85926A 4.INSPECT DRL RELAY (w/ Daytime Running Light)

E222294C84
1.073,0.958 1.302,0.49 1.302,0.49 1.438,0.49 false 1.063,1.333 1.146,1.75 1.146,1.75 1.344,1.75 false 0.802,1.01 0.938,0.49 0.938,0.49 1.063,0.49 false 0.563,1.281 0.635,1.76 0.635,1.76 0.823,1.76 false 1.458,0.406 1.563,0.563 0.104,0.156 10 false 1 1.375,1.667 1.479,1.823 0.104,0.156 10 false 2 1.094,0.396 1.198,0.552 0.104,0.156 10 false 5 0.844,1.667 0.948,1.823 0.104,0.156 10 false 3 0.198,0.188 0.51,0.385 0.313,0.198 10 false *a
*a Component without harness connected
(DRL Relay)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the DRL relay.