85916P
1.INSPECT H-LP RELAY
| *a | Component without harness connected
(H-LP Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the H-LP relay.
85926
2.INSPECT DIM RELAY
| *a | Component without harness connected
(DIM Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the DIM relay.
81550T
3.INSPECT BKUP LP RELAY
| *a | Component without harness connected
(BKUP LP Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the BKUP LP relay.
85926A
4.INSPECT DRL RELAY (w/ Daytime Running Light)
| *a | Component without harness connected
(DRL Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the DRL relay.