Home › Vehicle Exterior › LIGHTING (EXT) › AUTOMATIC LIGHT CONTROL SENSOR › from 2017.06
RM2170E _59 Vehicle Exterior _057049 LIGHTING (EXT) _0320155 AUTOMATIC LIGHT CONTROL SENSOR G

LIGHTING (EXT)  AUTOMATIC LIGHT CONTROL SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 89120A 1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

E236973C09
1.531,0.479 1.948,0.719 0.417,0.24 0.979,1.292 1.552,1.49 false 1.917,1.677 2.49,1.5 false 0.177,0.167 0.396,0.375 0.219,0.208 10 false *a 2.531,1.417 3,1.646 0.469,0.229 10 false CLTE 0.5,1.198 0.938,1.396 0.438,0.198 10 false CLTB 1.615,0.521 1.969,0.729 0.354,0.208 10 false G90
*a Front view of wire harness connector
(to Automatic Light Control Sensor)


a.

Disconnect the G90 automatic light control sensor connector.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G90-3 (CLTB) - G90-5 (CLTE) Power switch off Below 1 V
Power switch on (IG) 11 to 14 V


Standard Resistance:
Tester Connection Condition Specified Condition
G90-5 (CLTE) - Body ground Always Below 1 Ω


If the result is not as specified, there may be a malfunction on the wire harness side.


c.
E236974C17
1.51,0.635 1.938,0.896 0.427,0.26 0.833,1.635 1.5,1.896 false 0.833,2.323 1.5,2.115 false 0.167,0.156 0.354,0.292 0.188,0.135 10 false *a 1.604,0.688 2,0.948 0.396,0.26 10 false G90 0.427,1.531 1,1.781 0.573,0.25 10 false CLTS 0.427,2.25 0.99,2.51 0.563,0.26 10 false CLTE
*a Component with harness connected
(Automatic Light Control Sensor)


Connect the G90 automatic light control sensor connector.


d.

Connect an oscilloscope to terminals G90-4 (CLTS) and G90-5 (CLTE) of the automatic light control sensor connector.


e.
E223978N01
2.953,1.027 3.297,1.187 0.344,0.16 10 GND 1.854,1.152 1.984,1.313 0.13,0.16 10 A

Check the waveform.

OK:
Tester Connection Condition Tool Setting Specified Condition
G90-4 (CLTS) - G90-5 (CLTE) Power switch on (IG) 5 V/DIV., 5 ms./DIV. Pulse generation
(See waveform)


HINT:

The wavelength (A) of the waveform changes according to the surrounding brightness.


If the result is not as specified, the automatic light control sensor may be malfunctioning.