Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2017.06–2018.08
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277924 HYBRID CONTROL SYSTEM U

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  TERMINALS OF ECU  


C146689C70
1.354,1.427 1.688,1.625 0.333,0.198 2.802,1.427 3.135,1.625 0.333,0.198 4.26,1.438 4.563,1.635 0.302,0.198 5.531,1.427 5.833,1.625 0.302,0.198 0.104,0.073 0.646,0.469 0.542,0.396 10 false *a 1.417,1.458 1.865,1.688 0.448,0.229 10 false A71 2.865,1.448 3.375,1.698 0.51,0.25 10 false A72 4.292,1.458 4.729,1.677 0.438,0.219 10 false G80 5.573,1.448 6.083,1.656 0.51,0.208 10 false G81
*a Hybrid Vehicle Control ECU - -


Hybrid vehicle control ECU
Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
A71-1 (+B2) - G80-6 (E1) L - BR Power source Power switch on (IG) 11 to 14 V
A71-16 (VLO) - G80-6 (E1) R - BR DC/DC operation monitor / voltage change signal Power switch on (IG) Pulse generation
(Waveform 1)
A71-13 (IWP) - G80-6 (E1) G - BR Inverter water pump assembly signal Power switch on (READY) Pulse generation
(Waveform 2)
A71-14 (NIWP) - G80-6 (E1) P - BR Inverter water pump assembly signal Power switch on (READY) Pulse generation
(Waveform 2)
A72-2 (BL) - G80-6 (E1) R - BR Back up light Power switch on (IG), shift lever in R 11 to 14 V
A72-10 (CLK) - G80-6 (E1) G - BR A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 3)
A72-11 (STB) - G80-6 (E1) W - BR A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 3)
A71-25 (NODD) - G80-6 (E1) W - BR DC/DC operation DC/DC converter operating normally 5 to 7 V
DC/DC converter not operating normally 2 to 4 V
DC/DC converter operating prohibited 0.1 to 0.5 V
A71-24 (MMT) - A71-23 (MMTG) L - BR Motor temperature sensor Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A71-26 (GMT) - A71-27 (GMTG) B - R Generator temperature sensor Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
G81-29 (SI0) - G80-6 (E1) Y - BR HV battery blower fan operation signal Power switch on (IG), during Active Test Pulse generation
(Waveform 4)
A72-8 (ETI) - G80-6 (E1) R - BR A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 3)
A72-9 (ITE) - G80-6 (E1) Y - BR A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 3)
A72-13 (ILK) - G80-6 (E1) V - BR Interlock switch Power switch on (IG), inverter terminal cover, high-voltage input cables and service plug grip installed correctly 0 to 1.5 V
Power switch on (IG), inverter terminal cover, high-voltage input cables or service plug grip not installed 11 to 14 V
A71-3 (IG2) - G80-6 (E1) P - BR Power source Power switch on (IG) 11 to 14 V
A72-4 (+B1) - G80-6 (E1) L - BR Power source Power switch on (IG) 11 to 14 V
A72-6 (MREL) - G80-6 (E1) BE - BR Main relay Power switch on (IG) 11 to 14 V
A72-28 (ST1-) - G80-6 (E1) BR - BR Brake cancel switch Power switch on (IG), brake pedal depressed 0 to 1.5 V
Power switch on (IG), brake pedal released 11 to 14 V
A72-20 (N) - G80-6 (E1) Y - BR Shift lever position signal Power switch on (IG), shift lever in N 7.5 to 14 V
Power switch on (IG), shift lever not in N 0.5 to 1.5 V
A72-17 (PR) - G80-6 (E1) V - BR Shift lever position signal Power switch on (IG), shift lever in P or R 7.5 to 14 V
Power switch on (IG), shift lever not in P or R 0.5 to 1.5 V
A72-26 (DB1) - G80-6 (E1) L - BR Shift lever position signal Power switch on (IG), shift lever in D or B 7.5 to 14 V
Power switch on (IG), shift lever not in D or B 0.5 to 1.5 V
A72-14 (DB2) - G80-6 (E1) B - BR Shift lever position signal Power switch on (IG), shift lever in D or B 7.5 to 14 V
Power switch on (IG), shift lever not in D or B 0.5 to 1.5 V
A72-15 (R) - G80-6 (E1) SB - BR Shift lever position signal Power switch on (IG), shift lever in R 7.5 to 14 V
Power switch on (IG), shift lever not in R 0.5 to 1.5 V
A72-21 (P) - G80-6 (E1) BE - BR Shift lever position signal Power switch on (IG), shift lever in P 7.5 to 14 V
Power switch on (IG), shift lever not in P 0.5 to 1.5 V
A72-34 (PNB) - G80-6 (E1) G - BR Shift lever position signal Power switch on (IG), shift lever in P, N or B 7.5 to 14 V
A71-9 (VCPA) - A71-20 (EPA) Y - L Accelerator pedal sensor assembly power source (for VPA1) Power switch on (IG) 4.5 to 5.5 V
A71-8 (VCP2) - A71-18 (EPA2) G - W Accelerator pedal sensor assembly power source (for VPA2) Power switch on (IG) 4.5 to 5.5 V
A72-32 (CLK-) - G80-6 (E1) W - BR MG communication clock signal Power switch on (READY) Pulse generation
(Waveform 5)
A72-33 (CLK+) - G80-6 (E1) B - BR MG communication clock signal Power switch on (READY) Pulse generation
(Waveform 5)
A71-15 (STP) - G80-6 (E1) L - BR Stop light switch Brake pedal depressed 11 to 14 V
Brake pedal released 0 to 1.5 V
A72-24 (HTM+) - G80-6 (E1) B - BR Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (IG) Pulse generation
(Waveform 6)
A72-25 (HTM-) - G80-6 (E1) W - BR Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (IG) Pulse generation
(Waveform 6)
A71-30 (VPA) - A71-20 (EPA) R - L Accelerator pedal sensor assembly (for accelerator pedal position detection) Power switch on (IG), accelerator pedal released 0.4 to 1.4 V
Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed 2.6 to 4.5 V
A71-28 (VPA2) - A71-18 (EPA2) B - W Accelerator pedal sensor assembly (for accelerator pedal position detection) Power switch on (IG), accelerator pedal released 1.0 to 2.2 V
Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed 3.4 to 5.3 V
A72-22 (MTH-) - G80-6 (E1) W - BR Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 7)
A72-23 (MTH+) - G80-6 (E1) B - BR Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 7)
A72-12 (HSDN) - G80-6 (E1) B - BR MG ECU shutdown signal Power switch on (READY) 0 to 1.5 V
A72-30 (REQ-) - G80-6 (E1) W - BR MG ECU communication request signal Power switch on (IG) Pulse generation
(Waveform 8)
A72-31 (REQ+) - G80-6 (E1) B - BR MG ECU communication request signal Power switch on (IG) Pulse generation
(Waveform 8)
G80-1 (SMRG) - G80-5 (E01) Y - W-B System main relay operation signal Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 9)
G80-3 (SMRP) - G80-5 (E01) W - W-B System main relay operation signal Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 9)
G80-4 (SMRB) - G80-5 (E01) SB - W-B System main relay operation signal Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 9)
G80-9 (ST2) - G80-6 (E1) G - BR Starter signal Power switch on (IG) 0 to 1.5 V
G81-28 (TC) - G80-6 (E1) V - BR Diagnosis terminal Power switch on (IG) 11 to 14 V
G81-15 (EVSW) - G80-6 (E1) B - BR EV switch signal Power switch on (IG), EV switch not operated 11 to 14 V
Power switch on (IG), EV switch operated 0 to 1.5 V
G81-20 (THB) - G81-21 (ETHB) L - V Auxiliary battery temperature Power switch on (IG), auxiliary battery temperature 25°C (77°F) 1.7 to 2.3 V
Power switch on (IG), auxiliary battery temperature 60°C (140°F) 0.6 to 0.9 V
G81-14 (ABFS) - G80-6 (E1) R - BR Airbag activation signal Power switch on (READY) Pulse generation
(Waveform 10)
G80-32 (BTH+) - G80-6 (E1) R - BR Communication signal from battery smart unit to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 11)
G80-33 (BTH-) - G80-6 (E1) G - BR Communication signal from battery smart unit to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 11)
G81-3 (BATT) - G80-6 (E1) BE - BR Power source Power switch on (IG) 11 to 14 V
Power switch on (READY) 11 to 15.5 V
G81-24 (CA1L) - G80-6 (E1) W - BR CAN communication signal Power switch on (IG) Pulse generation
(Waveform 12)
G81-25 (CA1H) - G80-6 (E1) BE - BR CAN communication signal Power switch on (IG) Pulse generation
(Waveform 12)
G81-30 (CA3N) - G80-6 (E1) W - BR CAN communication signal Power switch on (IG) Pulse generation
(Waveform 13)
G81-31 (CA3P) - G80-6 (E1) R - BR CAN communication signal Power switch on (IG) Pulse generation
(Waveform 13)
G81-7 (PLKC) - G80-6 (E1) G - BR Shift lock release request signal Power switch on (READY), brake pedal depressed 11 to 14 V
Power switch on (READY), brake pedal released 0 to 1.5 V

Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
A217985E12
2.875,1 3.25,1.198 0.375,0.198 10 false GND

Waveform 1 (DC/DC operation monitor / voltage change signal)

Item Content
Terminal A71-16 (VLO) - G80-6 (E1)
Equipment Setting 5 V/DIV., 50 ms./DIV.
Condition Power switch on (IG)

HINT:

The cycle will vary depending on the specified voltage of the hybrid vehicle converter.



b.
A356772E03
0.354,0.865 0.938,1.167 0.583,0.302 10 false CH1 0.354,1.417 0.938,1.719 0.583,0.302 10 false CH2 2.969,0.854 3.365,1.021 0.396,0.167 10 false GND 2.979,1.635 3.375,1.802 0.396,0.167 10 false GND

Waveform 2 (Inverter water pump assembly signal)

Item Content
Terminal CH1: A71-13 (IWP) - G80-6 (E1)
CH2: A71-14 (NIWP) - G80-6 (E1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY)


c.
A379326E01
0.25,0.448 0.563,0.646 0.313,0.198 10 false CH1 0.25,0.865 0.563,1.063 0.313,0.198 10 false CH2 0.281,1.229 0.594,1.427 0.313,0.198 10 false CH3 0.313,1.646 0.625,1.844 0.313,0.198 10 false CH4 2.948,0.646 3.344,0.844 0.396,0.198 10 false GND 2.958,1 3.354,1.198 0.396,0.198 10 false GND 2.948,1.375 3.344,1.573 0.396,0.198 10 false GND 2.948,1.75 3.344,1.948 0.396,0.198 10 false GND

Waveform 3 (A/C communication signal)

Item Content
Terminal CH1: A72-10 (CLK) - G80-6 (E1)
CH2: A72-9 (ITE) - G80-6 (E1)
CH3: A72-8 (ETI) - G80-6 (E1)
CH4: A72-11 (STB) - G80-6 (E1)
Equipment Setting 10 V/DIV., 100 ms./DIV.
Condition Power switch on (READY), air conditioning system stopped

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



d.
A379327E01
3.031,1.021 3.406,1.219 0.375,0.198 10 false GND

Waveform 4 (HV battery blower fan operation signal)

Item Content
Terminal G81-29 (SI0) - G80-6 (E1)
Equipment Setting 5 V/DIV., 500 ms./DIV.
Condition Power switch on (IG), during Active Test

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



e.
A379251E02
0.25,0.625 0.708,0.823 0.458,0.198 10 false CH1 0.26,1.354 0.719,1.552 0.458,0.198 10 false CH2 2.948,1 3.406,1.198 0.458,0.198 10 false GND 2.938,1.573 3.396,1.771 0.458,0.198 10 false GND

Waveform 5 (MG communication clock signal)

Item Content
Terminal CH1: A72-33 (CLK+) - G80-6 (E1)
CH2: A72-32 (CLK-) - G80-6 (E1)
Equipment Setting 1 V/DIV., 1 μs./DIV.
Condition Power switch on (READY)


f.
A379254E01
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 6 (communication signal from hybrid vehicle control ECU to MG ECU)

Item Content
Terminal CH1: A72-24 (HTM+) - G80-6 (E1)
CH2: A72-25 (HTM-) - G80-6 (E1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



g.
A379254E01
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 7 (communication signal from MG ECU to hybrid vehicle control ECU)

Item Content
Terminal CH1: A72-23 (MTH+) - G80-6 (E1)
CH2: A72-22 (MTH-) - G80-6 (E1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



h.
A379252E02
0.344,0.625 0.688,0.854 0.344,0.229 10 false CH1 0.344,1.365 0.688,1.594 0.344,0.229 10 false CH2 2.938,1.01 3.281,1.24 0.344,0.229 10 false GND 2.938,1.563 3.281,1.792 0.344,0.229 10 false GND

Waveform 8 (MG ECU communication request signal)

Item Content
Terminal CH1: A72-31 (REQ+) - G80-6 (E1)
CH2: A72-30 (REQ-) - G80-6 (E1)
Equipment Setting 1 V/DIV., 1 ms./DIV.
Condition Power switch on (IG)


i.
C206010E17
2.958,0.635 3.292,0.875 0.333,0.24 10 false GND 2.958,1.021 3.292,1.26 0.333,0.24 10 false GND 2.958,1.406 3.292,1.646 0.333,0.24 10 false GND 0.198,0.635 0.531,0.875 0.333,0.24 10 false CH1 0.198,1.031 0.531,1.271 0.333,0.24 10 false CH2 0.198,1.427 0.531,1.667 0.333,0.24 10 false CH3

Waveform 9 (system main relay operation signal)

Item Content
Terminal CH1: G80-3 (SMRP) - G80-5 (E01)
CH2: G80-4 (SMRB) - G80-5 (E01)
CH3: G80-1 (SMRG) - G80-5 (E01)
Equipment Setting 10 V/DIV., 200 ms./DIV.
Condition Power switch on (IG) → Power switch on (READY)


j.
A379329E01
2.938,1.021 3.302,1.229 0.365,0.208 10 false GND

Waveform 10 (airbag activation signal)

Item Content
Terminal G81-14 (ABFS) - G80-6 (E1)
Equipment Setting 5 V/DIV., 500 ms./DIV.
Condition Power switch on (READY)


k.
A379330E01
2.948,1.01 3.406,1.208 0.458,0.198 10 false GND 2.948,1.563 3.406,1.76 0.458,0.198 10 false GND 0.188,0.625 0.646,0.823 0.458,0.198 10 false CH1 0.219,1.385 0.677,1.583 0.458,0.198 10 false CH2

Waveform 11 (communication signal from battery smart unit to hybrid vehicle control ECU)

Item Content
Terminal CH1: G80-32 (BTH+) - G80-6 (E1)
CH2: G80-33 (BTH-) - G80-6 (E1)
Equipment Setting 2 V/DIV., 500 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



l.
A379250E02
0.271,0.656 0.729,0.854 0.458,0.198 10 false CH1 0.271,1.313 0.729,1.51 0.458,0.198 10 false CH2 2.948,1.208 3.406,1.406 0.458,0.198 10 false GND 2.958,1.563 3.417,1.76 0.458,0.198 10 false GND

Waveform 12 (CAN communication signal)

Item Content
Terminal CH1: G81-25 (CA1H) - G80-6 (E1)
CH2: G81-24 (CA1L) - G80-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



m.
A379250E02
0.271,0.656 0.729,0.854 0.458,0.198 10 false CH1 0.271,1.313 0.729,1.51 0.458,0.198 10 false CH2 2.948,1.208 3.406,1.406 0.458,0.198 10 false GND 2.958,1.563 3.417,1.76 0.458,0.198 10 false GND

Waveform 13 (CAN communication signal)

Item Content
Terminal CH1: G81-31 (CA3P) - G80-6 (E1)
CH2: G81-30 (CA3N) - G80-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).




U158885E02
0.229,0.125 0.427,0.323 0.198,0.198 10 false *1 4.385,2.385 4.656,2.552 0.271,0.167 10 false C28 3.198,2.385 3.469,2.552 0.271,0.167 10 false A47

Text in Illustration
*1 Inverter with Converter Assembly - -

HINT:

Since the inverter with converter assembly uses waterproof connectors, the voltage and waveform cannot be inspected directly. Standard voltage readings and waveforms are indicated for reference only.


Inverter with converter assembly
Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Standard Condition
A47-1 (IGCT) - A47-28 (GND1) B - W MG ECU power source Power switch on (IG) 11 to 14 V
A47-3 (VLO) - A47-28 (GND1) R - W DC/DC operation monitor / voltage change signal Power switch on (IG) Pulse generation
(Waveform 1)
A47-5 (CLK+) - A47-28 (GND1) B - W MG ECU communication clock signal Power switch on (READY) Pulse generation
(Waveform 2)
A47-6 (REQ+) - A47-28 (GND1) B - W MG ECU communication request signal Power switch on (READY) Pulse generation
(Waveform 3)
A47-7 (MTH+) - A47-28 (GND1) B - W Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (READY) Pulse generation
(Waveform 4)
A47-8 (HTM+) - A47-28 (GND1) B - W Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (READY) Pulse generation
(Waveform 5)
A47-9 (+B2) - A47-28 (GND1) G - W MG ECU power source Power switch on (IG) 11 to 14 V
A47-10 (+B) - A47-28 (GND1) G - W MG ECU power source Power switch on (IG) 11 to 14 V
A47-12 (NODD) - A47-28 (GND1) W - W DC/DC operation DC/DC converter operating normally 5 to 7 V
DC/DC converter not operating normally 2 to 4 V
DC/DC converter operation prohibited 0.1 to 0.5 V
A47-15 (CLK-) - A47-28 (GND1) W - W MG ECU communication clock signal Power switch on (READY) Pulse generation
(Waveform 2)
A47-16 (REQ-) - A47-28 (GND1) W - W MG ECU communication request signal Power switch on (READY) Pulse generation
(Waveform 3)
A47-17 (MTH-) - A47-28 (GND1) W - W Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (READY) Pulse generation
(Waveform 4)
A47-18 (HTM-) - A47-28 (GND1) W - W Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (READY) Pulse generation
(Waveform 5)
A47-29 (GI) - A47-28 (GND1) B - W Camshaft position sensor signal Power switch on (READY), with engine running Pulse generation
(Waveform 6)
A47-31 (HSDN) - A47-28 (GND1) B - W MG shutdown signal Power switch on (READY) 0 to 1 V
A47-35 (ILKI) - A47-28 (GND1) V - W Interlock switch signal Power switch on (IG), inverter terminal cover, high-voltage input cables and service plug grip installed correctly Below 1 V
Power switch on (IG), inverter terminal cover, high-voltage input cables or service plug grip not installed 11 to 14
A47-36 (ILKO) - A47-28 (GND1) LG - W Interlock switch signal Power switch on (IG), inverter terminal cover, high-voltage input cables and service plug grip installed correctly Below 1 V
Power switch on (IG), inverter terminal cover, high-voltage input cables or service plug grip not installed 11 to 14
C28-1 (MRF) - C28-2 (MRFG) BR - G Motor resolver signal Motor resolver running Pulse generation
(Waveform 7)
C28-3 (MSN) - C28-4 (MSNG) L - R Motor resolver signal Motor resolver running Pulse generation
(Waveform 7)
C28-6 (MCS) - C28-5 (MCSG) W - Y Motor resolver signal Motor resolver running Pulse generation
(Waveform 7)
C28-7 (GSN) - C28-8 (GSNG) L - R Generator resolver signal Generator resolver running Pulse generation
(Waveform 8)
C28-10 (GCS) - C28-9 (GCSG) W - Y Generator resolver signal Generator resolver running Pulse generation
(Waveform 8)
C28-11 (GRF) - C28-12 (GRFG) BR - G Generator resolver signal Generator resolver running Pulse generation
(Waveform 8)

NOTICE:

Do not measure the voltage or waveform directly at the sealed side of the inverter with converter assembly connector. Doing so may damage the connector because the connector is waterproof.


Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
A217985E12
2.875,1 3.25,1.198 0.375,0.198 10 false GND

Waveform 1 (DC/DC operation monitor / voltage change signal)

Item Content
Terminal A47-3 (VLO) - A47-28 (GND1)
Equipment Setting 5 V/DIV., 50 ms./DIV.
Condition Power switch on (IG)

HINT:

The cycle will vary depending on the specified voltage of the hybrid vehicle converter.



b.
A379251E02
0.25,0.625 0.708,0.823 0.458,0.198 10 false CH1 0.26,1.354 0.719,1.552 0.458,0.198 10 false CH2 2.948,1 3.406,1.198 0.458,0.198 10 false GND 2.938,1.573 3.396,1.771 0.458,0.198 10 false GND

Waveform 2 (MG ECU communication clock signal)

Item Content
Terminal CH1: A47-5 (CLK+) - A47-28 (GND1)
CH2: A47-15 (CLK-) - A47-28 (GND1)
Equipment Setting 1 V/DIV., 1 μs./DIV.
Condition Power switch on (READY)


c.
A379252E02
0.344,0.625 0.688,0.854 0.344,0.229 10 false CH1 0.344,1.365 0.688,1.594 0.344,0.229 10 false CH2 2.938,1.01 3.281,1.24 0.344,0.229 10 false GND 2.938,1.563 3.281,1.792 0.344,0.229 10 false GND

Waveform 3 (MG ECU communication request signal)

Item Content
Terminal CH1: A47-6 (REQ+) - A47-28 (GND1)
CH2: A47-16 (REQ-) - A47-28 (GND1)
Equipment Setting 1 V/DIV., 1 ms./DIV.
Condition Power switch on (READY)


d.
A379254E01
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 4 (communication signal from MG ECU to hybrid vehicle control ECU)

Item Content
Terminal CH1: A47-7 (MTH+) - A47-28 (GND1)
CH2: A47-17 (MTH-) - A47-28 (GND1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (READY)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



e.
A379254E01
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 5 (communication signal from hybrid vehicle control ECU to MG ECU)

Item Content
Terminal CH1: A47-8 (HTM+) - A47-28 (GND1)
CH2: A47-18 (HTM-) - A47-28 (GND1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (READY)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



f.
A217984E07
2.802,1.146 3.146,1.323 0.344,0.177 10 false GND

Waveform 6 (Camshaft position sensor signal)

Item Content
Terminal A47-29 (GI) - A47-28 (GND1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY), with engine running

HINT:

The pulse cycle becomes shorter as the engine speed increases.



g.
A379253E02
0.271,0.615 0.729,0.813 0.458,0.198 10 false CH1 0.26,1.125 0.719,1.323 0.458,0.198 10 false CH2 0.281,1.396 0.74,1.594 0.458,0.198 10 false CH3 1.208,1.646 1.667,1.844 0.458,0.198 10 false A 2.948,0.646 3.406,0.844 0.458,0.198 10 false GND 2.948,1.115 3.406,1.313 0.458,0.198 10 false GND 2.948,1.385 3.406,1.583 0.458,0.198 10 false GND

Waveform 7 (motor resolver signal)

Item Content
Terminal CH1: C28-1 (MRF) - C28-2 (MRFG)
CH2: C28-3 (MSN) - C28-4 (MSNG)
CH3: C28-6 (MCS) - C28-5 (MCSG)
Equipment Setting CH1: 10 V/DIV., 1 ms./DIV.
CH2, 3: 5 V/DIV., 1 ms./DIV.
Condition Motor resolver running

HINT:

Pulse cycle A becomes shorter as the rotor speed increases.



h.
A379253E02
0.271,0.615 0.729,0.813 0.458,0.198 10 false CH1 0.26,1.125 0.719,1.323 0.458,0.198 10 false CH2 0.281,1.396 0.74,1.594 0.458,0.198 10 false CH3 1.208,1.646 1.667,1.844 0.458,0.198 10 false A 2.948,0.646 3.406,0.844 0.458,0.198 10 false GND 2.948,1.115 3.406,1.313 0.458,0.198 10 false GND 2.948,1.385 3.406,1.583 0.458,0.198 10 false GND

Waveform 8 (generator resolver signal)

Item Content
Terminal CH1: C28-11 (GRF) - C28-12 (GRFG)
CH2: C28-7 (GSN) - C28-8 (GSNG)
CH3: C28-10 (GCS) - C28-9 (GCSG)
Equipment Setting CH1: 10 V/DIV., 1 ms./DIV.
CH2, 3: 5 V/DIV., 1 ms./DIV.
Condition Generator resolver running

HINT:

Pulse cycle A becomes shorter as the rotor speed increases.