Home › Engine / Hybrid System › 1NZ-FXE (ENGINE CONTROL) › SFI SYSTEM(w/ Canister Pump Module) › from 2018.08
RM2170E _51 Engine / Hybrid System _057003 1NZ-FXE ENGINE CONTROL _0320444 SFI SYSTEM(w/ Canister Pump Module) U

1NZ-FXE ENGINE CONTROL  SFI SYSTEM(w/ Canister Pump Module)  TERMINALS OF ECM  


U158982E02
2.542,0.5 2.865,0.667 0.323,0.167 10 false C10 5.833,0.49 6.156,0.656 0.323,0.167 10 false A40

HINT:

The standard voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard voltage for that pair of terminals, displayed in the "Specified Condition" column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A40-1 (BATT) - C10-16 (E1) Y - W-B Auxiliary battery (for measuring auxiliary battery voltage and for ECM memory) Power switch off 11 to 16 V
A40-2 (+B) - C10-16 (E1) B - W-B Power source of ECM Power switch on (IG) 11 to 14 V
A40-3 (+B2) - C10-16 (E1) B - W-B Power source of ECM Power switch on (IG) 11 to 14 V
C10-29 (+BM) - C10-16 (E1) BR - W-B Power source of throttle actuator Power switch off 11 to 16 V
A40-37 (IGSW) - C10-16 (E1) P - W-B Power switch signal Power switch on (IG) 11 to 14 V
C10-75 (OC1+) - C10-74 (OC1-) BR - GR Camshaft timing oil control valve assembly operation signal Idling Pulse generation
(See waveform 1)
A40-46 (MREL) - C10-16 (E1) GR - W-B EFI-MAIN relay operation signal Power switch on (IG) 11 to 14 V
C10-91 (VG) - C10-92 (E2G) R - L Mass air flow meter sub-assembly signal Idling, shift lever in P, A/C switch off 0.5 to 3.0 V
C10-90 (THA) - C10-122 (ETHA) P - G Intake air temperature sensor signal Idling, intake air temperature 20°C (68°F) 0.5 to 3.4 V
C10-93 (THW) - C10-94 (ETHW) L - BR Engine coolant temperature sensor signal Idling, engine coolant temperature 80°C (176°F) 0.2 to 1.0 V
C10-115 (VCTA) - C10-116 (ETA) W - V Power source of throttle position sensor (specific voltage) Power switch on (IG) 4.5 to 5.5 V
C10-84 (VTA1) - C10-116 (ETA) Y - V Throttle position sensor signal (for engine control) Accelerator pedal fully released 0.5 to 1.1 V
C10-83 (VTA2) - C10-116 (ETA) GR - V Throttle position sensor signal (for sensor malfunction detection) Accelerator pedal fully released 2.1 to 3.1 V
C10-23 (HA1A) - C10-52 (E04) G - W-B Air fuel ratio sensor heater operation signal Idling with cold engine Pulse generation
(See waveform 2)
Power switch on (IG) 11 to 14 V
C10-133 (A1A+) - C10-16 (E1) R - W-B Air fuel ratio sensor signal Power switch on (IG) 3.3 V*
C10-134 (A1A-) - C10-16 (E1) G - W-B Air fuel ratio sensor signal Power switch on (IG) 2.9 V*
C10-22 (HT1B) - C10-52 (E04) L - W-B Heated oxygen sensor heater operation signal Idling with cold engine Below 3.0 V
Power switch on (IG) 11 to 14 V
C10-103 (OX1B) - C10-135 (EX1B) L - P Heated oxygen sensor signal Engine speed maintained at 2500 rpm for 2 minutes after warming up engine Pulse generation
(See waveform 3)
C10-20 (#10) - C10-51 (E01) GR - BR No. 1 fuel injector assembly signal Power switch on (IG) 11 to 14 V
Idling Pulse generation
(See waveform 4)
C10-17 (#20) - C10-51 (E01) P - BR No. 2 fuel injector assembly signal Power switch on (IG) 11 to 14 V
Idling Pulse generation
(See waveform 4)
C10-18 (#30) - C10-51 (E01) L - BR No. 3 fuel injector assembly signal Power switch on (IG) 11 to 14 V
Idling Pulse generation
(See waveform 4)
C10-19 (#40) - C10-51 (E01) Y - BR No. 4 fuel injector assembly signal Power switch on (IG) 11 to 14 V
Idling Pulse generation
(See waveform 4)
C10-123 (KNK1) - C10-124 (EKNK) R - G Knock control sensor signal Engine speed maintained at 2500 rpm after warming up engine Pulse generation
(See waveform 5)
C10-82 (VV1+) - C10-114 (VV1-) L - W Camshaft position sensor signal Idling Pulse generation
(See waveform 6)
C10-78 (NE+) - C10-110 (NE-) G - R Crank position sensor signal Idling Pulse generation
(See waveform 6)
A40-43 (G2O) - C10-16 (E1) B - W-B Camshaft revolution signal Idling Pulse generation
(See waveform 7)
C10-57 (IGT1) - C10-16 (E1) W - W-B No. 1 ignition coil assembly (ignition signal) Idling Pulse generation
(See waveform 8)
C10-56 (IGT2) - C10-16 (E1) V - W-B No. 2 ignition coil assembly (ignition signal) Idling Pulse generation
(See waveform 8)
C10-55 (IGT3) - C10-16 (E1) G - W-B No. 3 ignition coil assembly (ignition signal) Idling Pulse generation
(See waveform 8)
C10-54 (IGT4) - C10-16 (E1) LG - W-B No. 4 ignition coil assembly (ignition signal) Idling Pulse generation
(See waveform 8)
C10-102 (IGF1) - C10-16 (E1) Y - W-B Ignition coil assembly (ignition confirmation signal) Power switch on (IG) 4.5 to 5.5 V
Idling Pulse generation
(See waveform 8)
C10-76 (PRG) - C10-51 (E01) L - BR Purge VSV operation signal Power switch on (IG) 11 to 14 V
Idling, under purge control Pulse generation
(See waveform 9)
C10-60 (M+) - C10-59 (ME01) W - BR Throttle actuator operation signal
(positive terminal)
Idling with warm engine Pulse generation
(See waveform 10)
C10-30 (M-) - C10-59 (ME01) B - BR Throttle actuator operation signal
(negative terminal)
Idling with warm engine Pulse generation
(See waveform 11)
A40-21 (FC) - C10-51 (E01) R - BR Fuel pump control Power switch on (IG) 11 to 14 V
A40-27 (W) - C10-16 (E1) B - W-B Malfunction Indicator Lamp (MIL) operation signal Power switch on (IG)
(MIL goes on)
Below 3.0 V
Idling 11 to 14 V
A40-34 (VCPP) - A40-36 (EPPM) V - BE Power source of canister pressure sensor (specific voltage) Power switch on (IG) 4.5 to 5.5 V
A40-5 (VPMP) - C10-51 (E01) G - BR Vent valve (built into canister pump module) Power switch on (IG) 11 to 14 V
A40-18 (MPMP) - C10-51 (E01) BR - BR Leak detection pump (built into canister pump module) Leak detection pump off Below 3.0 V
Leak detection pump on 9 to 14 V
A40-35 (PPMP) - A40-36 (EPPM) L - BE Canister pressure sensor (built into canister pump module) Power switch on (IG) 3.0 to 3.6 V
A40-13 (CANH) - C10-16 (E1) L - W-B CAN communication line Power switch on (IG) Pulse generation
(See waveform 12)
A40-26 (CANL) - C10-16 (E1) W - W-B CAN communication line Power switch on (IG) Pulse generation
(See waveform 13)
A40-12 (CANP) - C10-16 (E1) B - W-B CAN communication line Power switch on (IG) Pulse generation
(See waveform 12)
A40-25 (CANN) - C10-16 (E1) W - W-B CAN communication line Power switch on (IG) Pulse generation
(See waveform 13)
A40-28 (WPI) - C10-16 (E1) G - W-B Engine water pump assembly signal Idling with warm engine Pulse generation
(See waveform 14)
A40-29 (WPO) - C10-16 (E1) L - W-B Engine water pump assembly signal Idling with warm engine Pulse generation
(See waveform 15)
C10-118 (VCPM) - C10-119 (EPIM) P - LG Power source of manifold absolute pressure sensor Power switch on (IG) 4.75 to 5.25 V
C10-87 (PIM) - C10-119 (EPIM) B - LG Manifold absolute pressure sensor signal Power switch on (IG) 3.0 to 5.0 V
C10-28 (EGR1) - C10-16 (E1) R - W-B EGR valve assembly EGR valve operating Pulse generation
(See waveform 16)
C10-27 (EGR2) - C10-16 (E1) G - W-B EGR valve assembly EGR valve operating Pulse generation
(See waveform 16)
C10-26 (EGR3) - C10-16 (E1) W - W-B EGR valve assembly EGR valve operating Pulse generation
(See waveform 16)
C10-25 (EGR4) - C10-16 (E1) Y - W-B EGR valve assembly EGR valve operating Pulse generation
(See waveform 16)
A40-45 (RFC) - C10-16 (E1) LG - W-B Cooling fan control Power switch on (IG), A/C switch on (max cool) Pulse generation
(See waveform 17)
A40-50 (EC) - Body ground W-B - - Earth (ground) circuit of ECM Always Below 1 Ω
C10-16 (E1) - Body ground W-B - - Earth (ground) circuit of ECM Always Below 1 Ω
C10-51 (E01) - Body ground BR - - Earth (ground) circuit of ECM Always Below 1 Ω
C10-21 (E02) - Body ground B - - Earth (ground) circuit of ECM Always Below 1 Ω
C10-52 (E04) - Body ground W-B - - Earth (ground) circuit of ECM Always Below 1 Ω
C10-59 (ME01) - Body ground BR - - Earth (ground) circuit of ECM Always Below 1 Ω
C10-58 (GE01) - Body ground BR - - Shielded earth (ground) circuit of throttle actuator Always Below 1 Ω

*: The ECM terminal voltage is constant regardless of the output voltage from the sensor.

WAVEFORM 1


U124196E07
0.448,0.167 0.99,0.365 0.542,0.198 10 false 5 V/DIV. 0.552,1.104 0.896,1.302 0.344,0.198 10 false GND 1.615,1.854 2.292,2.052 0.677,0.198 10 false 1 ms./DIV.

Camshaft Timing Oil Control Valve Assembly Signal
ECM Terminal Name Between OC1+ and OC1-
Tester Range 5 V/DIV., 1 ms./DIV.
Condition Idling


WAVEFORM 2


A205412E21
2.646,0.073 3.25,0.26 0.604,0.188 10 false 5 V/DIV. 2.698,0.906 3.063,1.073 0.365,0.167 10 false GND 1.115,1.854 1.875,2.031 0.76,0.177 10 false 10 ms./DIV.

Air Fuel Ratio Sensor (Sensor 1) Heater Operation Signal
ECM Terminal Name Between HA1A and E04
Tester Range 5 V/DIV., 10 ms./DIV.
Condition Idling


WAVEFORM 3


U113545E11
0.313,0.156 0.979,0.375 0.667,0.219 10 false 0.2 V/DIV. 0.552,1.479 0.917,1.677 0.365,0.198 10 false GND 1.76,1.875 2.583,2.073 0.823,0.198 10 false 200 ms./DIV.

Heated Oxygen Sensor (Sensor 2) Signal
ECM Terminal Name Between OX1B and EX1B
Tester Range 0.2 V/DIV., 200 ms./DIV.
Condition Engine speed maintained at 2500 rpm for 2 minutes after warming up engine

HINT:

In the Data List, the item O2S B1S2 shows the values input to the ECM from the heated oxygen sensor.



WAVEFORM 4


A381226E01
0.521,0.167 1.25,0.448 0.729,0.281 10 false 20 V/DIV. 0.615,1.583 1.344,1.865 0.729,0.281 10 false GND 1.625,1.927 3.427,2.177 1.802,0.25 10 true 20 ms./DIV.

No. 1 (to No. 4) Fuel Injector Assembly Signal
ECM Terminal Name Between #10 (to #40) and E01
Tester Range 20 V/DIV., 20 ms./DIV.
Condition Idling

HINT:

The wavelength becomes shorter as the engine speed increases.



WAVEFORM 5


A194185E11
2.969,1.615 3.313,1.781 0.344,0.167 10 false GND 2.74,1.094 3.271,1.271 0.531,0.177 10 false 1 V/DIV. 1.219,2.573 1.917,2.75 0.698,0.177 10 false 1 ms./DIV.

Knock Control Sensor Signal
ECM Terminal Name Between KNK1 and EKNK
Tester Range 1 V/DIV., 1 ms./DIV.
Condition Engine speed maintained at 2500 rpm after warming up engine

HINT:
·

The wavelength becomes shorter as the engine speed increases.

·

The waveforms and amplitudes displayed differ slightly depending on the vehicle condition.




WAVEFORM 6


A063955E82
2.781,0.604 3.271,0.75 0.49,0.146 10 false GND 2.781,1.417 3.271,1.563 0.49,0.146 10 false GND 1.844,1.927 3.427,2.177 1.583,0.25 10 true 20 ms./DIV. 0.167,0.583 0.552,0.927 0.385,0.344 10 false CH1 0.052,0.042 0.708,0.281 0.656,0.24 10 false 5 V/DIV. 0.167,1.385 0.479,2.177 0.313,0.792 10 true CH2

Crank Position Sensor and Cam Position Sensor Signal
ECM Terminal Name CH1: Between VV1+ and VV1-
CH2: Between NE+ and NE-
Tester Range 5 V/DIV., 20 ms./DIV.
Condition Idling

HINT:

The wavelength becomes shorter as the engine speed increases.



WAVEFORM 7


A214025E28
2.969,1.844 3.406,2.104 0.438,0.26 10 false GND 1.271,2.604 2.031,2.792 0.76,0.188 10 false 20 ms./DIV. 2.396,0.24 2.938,0.406 0.542,0.167 10 false 5 V/DIV.

Camshaft Revolution Signal from ECM to Hybrid Vehicle Control ECU and Inverter with Converter Assembly
ECM Terminal Name Between G2O and E1
Tester Range 5 V/DIV., 20 ms./DIV.
Condition Idling

HINT:

The wavelength becomes shorter as the engine speed increases.



WAVEFORM 8


A289263E01
2.844,0.857 3.210,1.059 0.366,0.202 10 GND 2.844,1.502 3.175,1.704 0.331,0.202 10 GND 0.058,0.41 0.435,0.915 0.376,0.504 10 CH1 (IGT) 0.021,1.193 0.440,1.551 0.419,0.358 10 CH2 (IGF1) 0.03,0.036 0.574,0.213 0.545,0.177 10 2 V/DIV. 1.154,1.844 1.905,1.988 0.751,0.145 10 20 ms./DIV.

Ignition Coil Assembly Signal (IGT and IGF Signal)
ECM Terminal Name CH1: Between IGT (1 to 4) and E1
CH2: Between IGF1 and E1
Tester Range 2 V/DIV., 20 ms./DIV.
Condition Idling

HINT:

The wavelength becomes shorter as the engine speed increases.



WAVEFORM 9


A218020E25
2.676,0.174 3.296,0.318 0.62,0.145 10 10 V/DIV. 2.806,0.925 3.143,1.065 0.337,0.14 10 GND 1.189,1.789 1.937,1.936 0.749,0.147 10 20 ms./DIV.

Purge VSV Signal
ECM Terminal Name Between PRG and E01
Tester Range 10 V/DIV., 20 ms./DIV.
Condition Idling, under purge control

HINT:

If the waveform is not similar to the illustration, check the waveform again after idling for 10 minutes or more.



WAVEFORM 10


A208000E60
2.856,0.973 3.187,1.119 0.331,0.147 10 GND 2.631,0.216 3.176,0.36 0.545,0.144 10 5 V/DIV. 0.501,0.616 0.722,0.759 0.221,0.143 10 M+ 1.323,1.806 1.995,1.965 0.672,0.159 10 1 ms./DIV.

Throttle Actuator Positive Terminal Signal
ECM Terminal Name Between M+ and ME01
Tester Range 5 V/DIV., 1 ms./DIV.
Condition Idling with warm engine

HINT:

The duty ratio varies depending on the throttle actuator operation.



WAVEFORM 11


A245848E54
2.849,0.99 3.182,1.142 0.333,0.151 10 GND 2.627,0.266 3.166,0.409 0.539,0.142 10 5 V/DIV. 0.479,0.626 0.664,0.777 0.184,0.15 10 M- 1.323,1.82 1.996,1.967 0.672,0.147 10 1 ms./DIV.

Throttle Actuator Negative Terminal Signal
ECM Terminal Name Between M- and ME01
Tester Range 5 V/DIV., 1 ms./DIV.
Condition Idling with warm engine

HINT:

The duty ratio varies depending on the throttle actuator operation.



WAVEFORM 12


A381227E01
2.958,1.396 3.344,1.656 0.385,0.26 10 false GND 2.792,0.292 3.365,0.552 0.573,0.26 10 false 1 V/DIV. 1.615,1.906 2.427,2.146 0.813,0.24 10 false 10 μs./DIV.

CAN Communication Signal (Reference)
ECM Terminal Name Between CANH and E1, or CANP and E1
Tester Range 1 V/DIV., 10 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.



WAVEFORM 13


A306171E01
3.031,1.365 3.427,1.573 0.396,0.208 10 false GND 2.813,0.208 3.427,0.458 0.615,0.25 10 false 1 V/DIV. 1.417,1.885 2.438,2.146 1.021,0.26 10 false 10 μs./DIV.

CAN Communication Signal (Reference)
ECM Terminal Name Between CANL and E1, or CANN and E1
Tester Range 1 V/DIV., 10 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform varies depending on the CAN communication signal.



WAVEFORM 14


A214025E28
2.969,1.844 3.406,2.104 0.438,0.26 10 false GND 1.271,2.604 2.031,2.792 0.76,0.188 10 false 20 ms./DIV. 2.396,0.24 2.938,0.406 0.542,0.167 10 false 5 V/DIV.

Engine Water Pump Assembly Signal (from Engine Water Pump Assembly to ECM)
ECM Terminal Name Between WPI and E1
Tester Range 5 V/DIV., 20 ms./DIV.
Condition Idling with warm engine

HINT:

The wavelength becomes shorter as the engine water pump assembly speed increases.



WAVEFORM 15


A214025E28
2.969,1.844 3.406,2.104 0.438,0.26 10 false GND 1.271,2.604 2.031,2.792 0.76,0.188 10 false 20 ms./DIV. 2.396,0.24 2.938,0.406 0.542,0.167 10 false 5 V/DIV.

Engine Water Pump Assembly Signal (from ECM to Engine Water Pump Assembly)
ECM Terminal Name Between WPO and E1
Tester Range 5 V/DIV., 20 ms./DIV.
Condition Idling with warm engine

HINT:

The duty ratio varies depending on the engine water pump assembly speed.



WAVEFORM 16


A214026E01
2.849,2.294 3.179,2.450 0.330,0.156 10 GND 2.849,1.922 3.179,2.077 0.330,0.156 10 GND 2.849,1.578 3.179,1.734 0.330,0.156 10 GND 2.849,1.24 3.179,1.396 0.330,0.156 10 GND 0.235,1.039 0.686,1.195 0.451,0.156 10 EGR1 0.235,1.405 0.686,1.560 0.451,0.156 10 EGR2 0.235,1.757 0.686,1.913 0.451,0.156 10 EGR3 0.235,2.113 0.686,2.269 0.451,0.156 10 EGR4 1.248,2.42 1.997,2.577 0.749,0.157 10 50 ms./DIV. 1.979,0.406 2.643,0.581 0.665,0.175 10 20 V/DIV.

EGR Valve Assembly Signal
ECM Terminal Name Between EGR1 and E1
Between EGR2 and E1
Between EGR3 and E1
Between EGR4 and E1
Tester Range 20 V/DIV., 50 ms./DIV.
Condition EGR valve operating


WAVEFORM 17


A247290E23
2.74,2.281 3.094,2.438 0.354,0.156 10 false GND 1.177,2.604 2.094,2.969 0.917,0.365 10 false 2 ms./DIV. 2.563,0.854 3.125,1.052 0.563,0.198 10 false 1 V/DIV

Cooling Fan Control Signal
ECM Terminal Name Between RFC and E1
Tester Range 1 V/DIV., 2 ms./DIV.
Condition Power switch on (IG), A/C switch on (max cool)

HINT:

The duty ratio varies depending on the engine coolant temperature.