Home › Engine / Hybrid System › 1NZ-FXE (ENGINE CONTROL) › SFI SYSTEM(w/ Canister Pump Module) › from 2018.08
RM2170E _51 Engine / Hybrid System _057003 1NZ-FXE ENGINE CONTROL _0320444 SFI SYSTEM(w/ Canister Pump Module) C

1NZ-FXE ENGINE CONTROL  SFI SYSTEM(w/ Canister Pump Module)  P00FE  EVAP System Tank Vapor Line Restricted/Blocked  


DTC SUMMARY

DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic
P00FE EVAP System Tank Vapor Line Restricted/Blocked Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured.
When the fuel level in the fuel tank is 85% or less and the leak detection pump is operating, the EVAP system pressure decreases quickly.
·

Fuel tank vent hose

·

Fuel tank assembly (cut-off valve, roll over valve)

·

Canister

·

ECM


While power switch off 2 trip

DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System.

Click hereEngine / Hybrid System>1NZ-FXE (ENGINE CONTROL)>SFI SYSTEM(w/ Canister Pump Module)>EVAP System

MONITOR DESCRIPTION

5 hours* after the power switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the power switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the power switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer, 5, 7 or 9.5 hours after power switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa to 110 kPa(abs) [525 mmHg(abs) to 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A269951E03
1.219,0.771 1.198,0.906 false 1.219,3.135 1.198,3.26 false 1.625,2.167 1.75,2.417 false 1.146,1.729 0.813,1.813 false 1.604,0.927 1.635,0.427 1.635,0.427 1.719,0.427 false 2.271,0.885 2.302,0.417 2.302,0.417 2.385,0.417 false 1.792,1.594 1.896,1.24 1.896,1.24 1.979,1.24 false 1.833,3.948 1.938,3.583 1.938,3.583 2.021,3.583 false 5.094,3.125 5.063,3.25 false 5.719,3.958 5.823,3.594 5.823,3.594 5.906,3.594 false 5.083,0.771 5.052,0.906 false 5.5,2.167 5.635,2.417 false 5.656,1.594 5.771,1.24 5.771,1.24 5.854,1.24 false 1.469,1.958 0.802,2.208 false 1.417,1.344 1.292,1.271 1.292,1.271 1.208,1.271 false 2.333,1.427 2.344,1.229 2.344,1.229 2.427,1.229 false 2.813,1.927 2.833,1.771 2.833,1.771 2.906,1.771 false 1.594,4.51 0.896,4.51 false 5.448,4.51 4.75,4.51 false 0.365,0.135 0.552,0.313 0.188,0.177 10 false *a 1.115,0.906 1.302,1.083 0.188,0.177 10 false *1 1.719,0.333 1.906,0.51 0.188,0.177 10 false *9 4.281,0.135 4.469,0.313 0.188,0.177 10 false *b 4.281,2.688 4.469,2.865 0.188,0.177 10 false *d 0.365,2.688 0.552,2.865 0.188,0.177 10 false *c 1.115,3.271 1.302,3.448 0.188,0.177 10 false *1 1.677,2.417 1.865,2.594 0.188,0.177 10 false *5 0.729,4.427 0.917,4.604 0.188,0.177 10 false *6 1.99,1.156 2.156,1.333 0.167,0.177 10 false *3 2.042,3.5 2.208,3.677 0.167,0.177 10 false *4 3.458,3.354 3.625,3.531 0.167,0.177 10 false *e 3.458,3.74 3.625,3.917 0.167,0.177 10 false *f 5,3.271 5.188,3.448 0.188,0.177 10 false *2 5.917,3.51 6.083,3.688 0.167,0.177 10 false *4 4.979,0.917 5.167,1.094 0.188,0.177 10 false *1 5.563,2.417 5.75,2.594 0.188,0.177 10 false *6 5.854,1.156 6.021,1.333 0.167,0.177 10 false *3 0.979,1.188 1.219,1.365 0.24,0.177 10 false *10 0.667,1.729 0.833,1.906 0.167,0.177 10 false *7 0.646,2.135 0.813,2.313 0.167,0.177 10 false *8 2.958,1.708 3.208,1.885 0.25,0.177 10 false *12 2.469,1.167 2.719,1.344 0.25,0.177 10 false *11 2.438,0.354 2.688,0.531 0.25,0.177 10 false *13 4.594,4.438 4.781,4.615 0.188,0.177 10 false *6

Text in Illustration
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 No. 1 Canister
*11 Canister Pump Module *12 Canister Filter
*13 Fuel Tank - -
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure

(a) P00FE: EVAP vent line blocked

During operation C, if the EVAP system pressure is below the threshold after 21.3 seconds, the ECM will determine that there is blockage between the fuel tank and canister, illuminate the MIL and store this DTC (2 trip detection logic).

A421323E17
0.406,0.573 1.177,0.885 0.771,0.313 10 false Purge VSV 0.438,1.115 1.208,1.427 0.771,0.313 10 false Vent Valve 0.167,1.479 1.104,1.833 0.938,0.354 10 false Leak Detection Pump 0.135,2.031 1.177,2.365 1.042,0.333 10 false EVAP Pressure 0.219,2.292 1.26,2.625 1.042,0.333 10 false Positive 0.229,2.667 1.271,3 1.042,0.333 10 false Negative 0.063,3.083 1.063,3.51 1,0.427 10 false First Reference Pressure 0.396,4.208 1.479,4.448 1.083,0.24 10 false Sequence 0.146,4.479 1.323,4.698 1.177,0.219 10 false Time (Seconds) 3.938,1 4.708,1.313 0.771,0.313 10 false ON 5.094,0.479 5.865,0.792 0.771,0.313 10 false ON 3.948,1.49 4.719,1.802 0.771,0.313 10 false ON 5.458,0.365 6.229,0.677 0.771,0.313 10 false ON: Open 6.25,0.688 7.125,1 0.875,0.313 10 false OFF: Closed 5.469,0.885 6.24,1.198 0.771,0.313 10 false ON: Closed 6.26,1.188 7.031,1.5 0.771,0.313 10 false OFF: Vent 3.469,4.385 4.792,4.677 1.323,0.292 10 false Within 15 minutes 3.906,4.125 5.229,4.417 1.323,0.292 10 false C 3.833,3.229 4.604,3.542 0.771,0.313 10 false OK 3.365,2.698 4.563,3.052 1.198,0.354 10 false 21.3 seconds 1.198,3.698 2.74,4.021 1.542,0.323 10 true EVAP Vent Line Blocked 1.667,4.135 2.99,4.427 1.323,0.292 10 false A 2.583,4.125 3.906,4.417 1.323,0.292 10 false B 5.135,4.135 6.458,4.427 1.323,0.292 10 false D 5.708,4.146 7.031,4.438 1.323,0.292 10 false E 1.635,4.448 2.271,4.635 0.635,0.188 10 false 60 2.51,4.458 3.146,4.646 0.635,0.188 10 false 360 5.115,4.438 5.75,4.625 0.635,0.188 10 false 10 5.708,4.458 6.344,4.646 0.635,0.188 10 false 60 0.063,0.063 3.021,0.385 2.958,0.323 10 false EVAP Pressure when EVAP vent line blocked:

MONITOR STRATEGY

Required Sensors/Components (Main) Purge VSV
Canister pump module
Required Sensors/Components (Related) Fuel level sensor
Frequency of Operation Once per driving cycle

CONFIRMATION DRIVING PATTERN

NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 85% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).



1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for at least 30 seconds.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

7.

After the "Evaporative System Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

8.

Input the DTC: P00FE.

9.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.




PROCEDURE

1.GO TO EVAP SYSTEM

NEXT

END