Home › Engine / Hybrid System › 1NZ-FXE (ENGINE CONTROL) › SFI SYSTEM(w/ Canister Pump Module) › from 2018.08
RM2170E _51 Engine / Hybrid System _057003 1NZ-FXE ENGINE CONTROL _0320444 SFI SYSTEM(w/ Canister Pump Module) C

1NZ-FXE ENGINE CONTROL  SFI SYSTEM(w/ Canister Pump Module)  P0441  Evaporative Emission Control System Incorrect Purge Flow  


DTC SUMMARY

DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic
P0441 Purge VSV (Vacuum Switching Valve) stuck open Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure is measured at start and at end of leak check.
If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that purge VSV stuck open.
·

Purge VSV

·

Connector/wire harness (purge VSV - ECM)

·

ECM

·

Canister pump module

·

Leak from EVAP system


While power switch off 2 trip
Purge VSV stuck closed After EVAP leak check performed, purge VSV turned on (open), and atmospheric air introduced into EVAP system. Reference pressure is measured at start and at end of check.
If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed.
·

Purge VSV

·

Purge line

·

Connector/wire harness (purge VSV - ECM)

·

ECM

·

Canister pump module

·

Canister (filter inside canister clogged)

·

No. 1 canister (filter inside canister clogged)

·

Leak from EVAP system


While power switch off 2 trip
Purge flow While engine running, following conditions successively met:
·

Negative pressure not created in EVAP system when purge VSV turned on (open)

·

EVAP system pressure change less than 0.5 kPa(gauge) [3.751 mmHg(gauge)] when vent valve turned on (closed)

·

Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa(gauge) [0.75 mmHg(gauge)]


·

Purge VSV

·

Purge line

·

Connector/wire harness (purge VSV - ECM)

·

ECM

·

Canister pump module

·

Canister (filter inside canister clogged)

·

No. 1 canister (filter inside canister clogged)

·

Leak from EVAP system


While engine running 2 trip

DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System.

Click hereEngine / Hybrid System>1NZ-FXE (ENGINE CONTROL)>SFI SYSTEM(w/ Canister Pump Module)>EVAP System

MONITOR DESCRIPTION

The 2 monitors, Key-off and purge flow, are used to detect malfunctions relating to DTC P0441. The Key-off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours after the power switch is turned off. The purge flow monitor runs while the engine is running.

1.

KEY-OFF MONITOR

5 hours* after the power switch is turned off, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the power switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the power switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after power switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV opened and then EVAP system pressure is measured by ECM.
A large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A269951E02
1.219,0.771 1.198,0.906 false 1.219,3.135 1.198,3.26 false 1.625,2.167 1.75,2.417 false 1.146,1.729 0.813,1.813 false 1.604,0.927 1.635,0.427 1.635,0.427 1.719,0.427 false 2.271,0.885 2.302,0.417 2.302,0.417 2.385,0.417 false 1.792,1.594 1.896,1.24 1.896,1.24 1.979,1.24 false 1.833,3.948 1.938,3.583 1.938,3.583 2.021,3.583 false 5.094,3.125 5.063,3.25 false 5.719,3.958 5.823,3.594 5.823,3.594 5.906,3.594 false 5.083,0.771 5.052,0.906 false 5.5,2.167 5.635,2.417 false 5.656,1.594 5.771,1.24 5.771,1.24 5.854,1.24 false 1.469,1.958 0.802,2.208 false 1.417,1.344 1.292,1.271 1.292,1.271 1.208,1.271 false 2.333,1.427 2.344,1.229 2.344,1.229 2.427,1.229 false 2.813,1.927 2.833,1.771 2.833,1.771 2.906,1.771 false 1.594,4.51 0.896,4.51 false 5.448,4.51 4.75,4.51 false 0.365,0.135 0.552,0.313 0.188,0.177 10 false *a 1.115,0.906 1.302,1.083 0.188,0.177 10 false *1 1.719,0.333 1.906,0.51 0.188,0.177 10 false *9 4.281,0.135 4.469,0.313 0.188,0.177 10 false *b 4.281,2.688 4.469,2.865 0.188,0.177 10 false *d 0.365,2.688 0.552,2.865 0.188,0.177 10 false *c 1.115,3.271 1.302,3.448 0.188,0.177 10 false *1 1.677,2.417 1.865,2.594 0.188,0.177 10 false *5 0.729,4.427 0.917,4.604 0.188,0.177 10 false *6 1.99,1.156 2.156,1.333 0.167,0.177 10 false *3 2.042,3.5 2.208,3.677 0.167,0.177 10 false *4 3.458,3.354 3.625,3.531 0.167,0.177 10 false *e 3.458,3.74 3.625,3.917 0.167,0.177 10 false *f 5,3.271 5.188,3.448 0.188,0.177 10 false *2 5.917,3.51 6.083,3.688 0.167,0.177 10 false *4 4.979,0.917 5.167,1.094 0.188,0.177 10 false *1 5.563,2.417 5.75,2.594 0.188,0.177 10 false *6 5.854,1.156 6.021,1.333 0.167,0.177 10 false *3 0.979,1.188 1.219,1.365 0.24,0.177 10 false *10 0.667,1.729 0.833,1.906 0.167,0.177 10 false *7 0.646,2.135 0.813,2.313 0.167,0.177 10 false *8 2.958,1.708 3.208,1.885 0.25,0.177 10 false *12 2.469,1.167 2.719,1.344 0.25,0.177 10 false *11 2.438,0.354 2.688,0.531 0.25,0.177 10 false *13 4.594,4.438 4.781,4.615 0.188,0.177 10 false *6

Text in Illustration
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 No. 1 Canister
*11 Canister Pump Module *12 Canister Filter
*13 Fuel Tank - -
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure

(a)

Purge VSV stuck open

In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM using the canister pressure sensor. If the stabilized system pressure is higher than [second reference pressure x 0.2], the ECM interprets this as the purge VSV being stuck open. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).

U113581E05
3.99,3.219 3.719,3.552 false 4.49,2.229 4.667,2.448 false 1.031,3.302 1.115,3.448 false 6.365,2.656 6.01,2.927 false 0.052,0.031 2.708,0.313 2.656,0.281 10 true EVAP Pressure when Purge Stuck Open: 0.333,0.49 1.125,0.698 0.792,0.208 10 false Purge VSV 0.344,0.938 1.177,1.146 0.833,0.208 10 false Vent Valve 0.146,1.344 1.125,1.719 0.979,0.375 10 false Leak Detection Pump 1.563,4.302 1.76,4.521 0.198,0.219 10 false 60 3.656,2.063 4.49,2.271 0.833,0.208 10 false Malfunction 6.198,0.354 7.042,0.594 0.844,0.24 10 true ON: Open 6.198,0.615 7.083,0.823 0.885,0.208 10 true OFF: Closed 6.198,0.885 7.083,1.094 0.885,0.208 10 false ON: Closed 6.208,1.156 7.063,1.396 0.854,0.24 10 true OFF: Vent 0.083,1.906 1.177,2.115 1.094,0.208 10 false EVAP Pressure 0.198,2.24 1.052,2.458 0.854,0.219 10 false Positive 0.177,2.563 1.198,2.781 1.021,0.219 10 false Negative 0.031,3.063 1.021,3.448 0.99,0.385 10 false First Reference Pressure 0.438,4 1.177,4.208 0.74,0.208 10 false Sequence 0.135,4.313 1.208,4.521 1.073,0.208 10 false Time (Seconds) 4.01,3.083 4.292,3.292 0.281,0.208 10 false OK 4.031,1.51 4.51,1.719 0.479,0.208 10 false ON 4.021,1.021 4.5,1.229 0.479,0.208 10 false ON 5.052,0.469 5.531,0.677 0.479,0.208 10 false ON 5.104,4.052 5.313,4.26 0.208,0.208 10 false D 5.667,4.052 5.875,4.26 0.208,0.208 10 false E 3.854,4.052 4.063,4.26 0.208,0.208 10 false C 2.542,4.052 2.75,4.26 0.208,0.208 10 false B 1.604,4.052 1.813,4.26 0.208,0.208 10 false A 6.396,2.573 7.042,3.417 0.646,0.844 10 false [Second Reference Pressure] x 0.2 3.417,4.313 4.615,4.521 1.198,0.208 10 false Within 15 minutes 2.469,4.302 2.771,4.521 0.302,0.219 10 false 360 5.073,4.292 5.271,4.51 0.198,0.219 10 false 10 5.635,4.302 5.833,4.521 0.198,0.219 10 false 60

(b)

Purge VSV stuck closed

In operation D, the canister pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for the purge VSV monitor begins when the purge VSV is turned on (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa(gauge) [2.25 mmHg(gauge)] or higher, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed, illuminates the MIL and stores the DTC (2 trip detection logic).

U124197E04
4.823,2.198 5.156,2.667 false 4.635,2.781 5.271,3.667 false 0.042,0.021 3.635,0.25 3.594,0.229 10 false EVAP Pressure when Purge VSV Stuck Closed: 0.292,0.458 1.042,0.677 0.75,0.219 10 false Purge VSV 0.375,0.927 1.073,1.146 0.698,0.219 10 false Vent Valve 0.177,1.302 1.125,1.656 0.948,0.354 10 false Leak Detection Pump 0.083,1.865 1.188,2.073 1.104,0.208 10 false EVAP Pressure 0.146,2.271 0.844,2.479 0.698,0.208 10 false Positive 0.146,2.542 0.927,2.75 0.781,0.208 10 false Negative 0.073,3.156 1.083,3.51 1.01,0.354 10 false First Reference Pressure 0.417,3.99 1.146,4.219 0.729,0.229 10 false Sequence 0.156,4.323 1.229,4.531 1.073,0.208 10 false Time (Seconds) 1.563,4.302 1.792,4.521 0.229,0.219 10 false 60 2.458,4.302 2.76,4.5 0.302,0.198 10 false 360 3.875,2.667 4.844,2.885 0.969,0.219 10 false Malfunction 4.573,1.99 4.917,2.198 0.344,0.208 10 false OK 3.833,1.51 4.229,1.719 0.396,0.208 10 false ON 3.813,1.031 4.208,1.24 0.396,0.208 10 false ON 5.063,0.479 5.458,0.688 0.396,0.208 10 false ON 1.615,4 1.792,4.208 0.177,0.208 10 false A 2.542,4.01 2.719,4.219 0.177,0.208 10 false B 3.865,4 4.042,4.208 0.177,0.208 10 false C 5.115,4.01 5.292,4.219 0.177,0.208 10 false D 5.688,4 5.865,4.208 0.177,0.208 10 false E 3.417,4.313 5.104,4.521 1.688,0.208 10 false Within 15 minutes 5.083,4.302 5.313,4.521 0.229,0.219 10 false 10 5.667,4.313 5.896,4.51 0.229,0.198 10 false 60 6.281,0.302 6.969,0.521 0.688,0.219 10 false ON: Open 6.281,0.594 7.115,0.813 0.833,0.219 10 true OFF: Closed 6.281,1.156 7.042,1.406 0.76,0.25 10 true OFF: Vent 6.281,0.885 7.052,1.104 0.771,0.219 10 false ON: Closed


2.

PURGE FLOW MONITOR

The purge flow monitor consists of 2 monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.

A112640E85
4.131,2.129 4.389,2.330 0.258,0.201 10 OK 3.266,1.756 3.524,1.957 0.258,0.201 10 OK 1.763,1.366 2.791,1.590 1.029,0.224 10 EVAP Pressure 2.094,0.979 2.794,1.176 0.701,0.198 10 Vent Valve 2.053,0.619 2.794,0.811 0.741,0.192 10 Purge VSV 0.056,0.002 2.783,0.229 2.728,0.228 10 EVAP Pressure During Purge Flow Monitor: 4.644,0.56 5.021,0.740 0.378,0.181 10 Open 4.45,1.539 6.936,1.711 2.486,0.173 10 0.1 kPa(gauge) [0.75 mmHg(gauge)] 4.45,1.926 7.005,2.099 2.555,0.173 10 0.5 kPa(gauge) [3.751 mmHg(gauge)] 4.367,1.251 5.125,1.437 0.758,0.186 10 Malfunction 2.806,2.397 3.557,2.598 0.751,0.201 10 1st Monitor 3.633,2.397 4.416,2.598 0.783,0.201 10 2nd Monitor 4.644,0.918 5.442,1.104 0.799,0.186 10 ON (Closed) 4.082,0.65 4.61,0.65 false 4.082,1 4.61,1 false


·

The 1st monitor

While the engine is running and the purge VSV is on (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.

·

The 2nd monitor

The vent valve is turned on (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.5 kPa(gauge) [3.751 mmHg(gauge)], the ECM interprets this as the purge VSV being stuck closed, illuminates the MIL and stores DTC P0441 (2 trip detection logic).


Atmospheric pressure check:

In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

MONITOR STRATEGY

Required Sensors/Components (Main) Purge VSV
Canister pump module
Required Sensors/Components (Related) -
Frequency of Operation Once per driving cycle

CONFIRMATION DRIVING PATTERN

1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for at least 30 seconds.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Put the engine in inspection mode (maintenance mode).

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INSPECTION MODE PROCEDURE

7.

Start the engine and wait 15 minutes or more.

8.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

9.

Read the pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



10.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

11.

Input the DTC: P0441.

12.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

You should perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the following procedure.



NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 85% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).



13.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

14.

Turn the power switch off and wait for at least 30 seconds.

15.

Turn the power switch on (IG) and turn the GTS on.

16.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

17.

After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

18.

Input the DTC: P0441.

19.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.




PROCEDURE

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0441)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


e.

Read the DTC.

Result
Result Proceed to
DTC P0441 is output A
DTC P0441 and other DTCs are output B

HINT:

If any DTCs other than DTC P0441 are output, troubleshoot those DTCs first.




A

B