The resistance of the thermistor built into the generator temperature sensor changes in accordance with changes in MG1 temperature. The lower the MG1 temperature, the higher the thermistor resistance. Conversely, the higher the MG1 temperature, the lower the resistance.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A37 | 260 | Generator temperature sensor output does not increase in which the value should increase, or output does not decrease under conditions in which the value should decrease. | ·
Wire harness or connector ·
Hybrid vehicle generator assembly (Generator temperature sensor) |
| P0A3A | 258 | Unusual sudden change in generator temperature sensor output occurs and the condition continues, or unusual sudden change in generator temperature sensor output occurs repeatedly. |
Refer to the wiring diagram for DTC P0A38-257.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A38-257
If DTC P0A37-260 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.
Drive the vehicle (stop and go driving) on urban roads for approximately 5 minutes.
If the Data List item "Motor Temp No2" shows both increases and decreases in temperature, suspected areas indicated by this DTC are not malfunctioning.
If DTC P0A3A-258 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.
Turn the power switch on (READY) and wait for 30 seconds or more.
Drive the vehicle for approximately 5 minutes according to the freeze frame data items "Vehicle Spd", "Inverter Coolant Water Temperature", "Motor Temp No1" and "Motor Temp No2".
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2C-247
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the A21 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A21-26 (GMT) - A21-27 (GMTG) | Power switch off | 0.3436 to 1442 kΩ |
Reconnect the A21 power management control ECU connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2B-250
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the DA1 engine room relay block and junction block assembly connector.
Disconnect the A21 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| DA1-12 (GMT) - A21-26 (GMT) | Power switch off | Below 1 Ω |
| DA1-13 (GMTG) - A21-27 (GMTG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| DA1-12 (GMT) - Other terminals | Power switch off | 10 kΩ or higher |
| DA1-13 (GMTG) - Other terminals | Power switch off | 10 kΩ or higher |
Reconnect the A21 power management control ECU connector.
Reconnect the DA1 engine room relay block and junction block assembly connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A38-257
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the DA1 engine room relay block and junction block assembly connector.
Disconnect the D7 hybrid vehicle generator assembly (generator temperature sensor) connector.
Measure the resistance according to the value(s) in the table below.
When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| DA1-12 (GMT) - D7-8 (GMT) | Power switch off | Below 1 Ω |
| DA1-13 (GMTG) - D7-4 (GMTG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| DA1-12 (GMT) - Other terminals | Power switch off | 10 kΩ or higher |
| DA1-13 (GMTG) - Other terminals | Power switch off | 10 kΩ or higher |
Reconnect the D7 hybrid vehicle generator assembly (generator temperature sensor) connector.
Reconnect the DA1 engine room relay block and junction block assembly connector.
OK
NG
Disconnect the DA1 engine room relay block and junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DA1-12 (GMT) - DA1-13 (GMTG) | Power switch off | 0.3436 to 1442 kΩ |
Reconnect the DA1 engine room relay block and junction block assembly connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A38-257
| Proceed to |
|---|
| OK |
| NG |
OK
NG