Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2012.10
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A37-260  Generator Temperature Sensor Circuit Range / Performance  P0A3A-258  Generator Temperature Sensor Circuit Intermittent  


DESCRIPTION

The resistance of the thermistor built into the generator temperature sensor changes in accordance with changes in MG1 temperature. The lower the MG1 temperature, the higher the thermistor resistance. Conversely, the higher the MG1 temperature, the lower the resistance.

A172965E06
2.044,0.334 2.299,0.484 0.255,0.151 10 120 2.044,0.477 2.299,0.628 0.255,0.151 10 110 2.044,0.617 2.299,0.768 0.255,0.151 10 100 2.119,0.747 2.299,0.898 0.180,0.151 10 90 2.126,0.88 2.299,1.031 0.173,0.151 10 80 2.119,1.017 2.299,1.167 0.180,0.151 10 70 2.119,1.146 2.299,1.297 0.180,0.151 10 60 2.119,1.279 2.299,1.430 0.180,0.151 10 50 2.119,1.419 2.299,1.570 0.180,0.151 10 40 2.119,1.559 2.299,1.710 0.180,0.151 10 30 2.119,1.693 2.299,1.843 0.180,0.151 10 20 2.119,1.833 2.299,1.983 0.180,0.151 10 10 0.9,1.055 1.934,1.206 1.034,0.151 10 Resistance (kΩ) 5.481,2.239 6.967,2.390 1.486,0.151 10 Temperature (°C (°F )) 2.312,2.169 2.492,2.320 0.180,0.151 10 10 2.256,2.319 2.536,2.470 0.281,0.151 10 (50) 2.725,2.319 3.006,2.470 0.281,0.151 10 (59) 3.18,2.319 3.461,2.470 0.281,0.151 10 (68) 3.646,2.319 3.927,2.470 0.281,0.151 10 (77) 4.108,2.319 4.389,2.470 0.281,0.151 10 (86) 4.557,2.319 4.838,2.470 0.281,0.151 10 (95) 4.965,2.319 5.309,2.470 0.343,0.151 10 (104) 2.753,2.169 2.933,2.320 0.180,0.151 10 15 3.229,2.169 3.409,2.320 0.180,0.151 10 20 3.695,2.169 3.875,2.320 0.180,0.151 10 25 4.143,2.169 4.324,2.320 0.180,0.151 10 30 4.595,2.169 4.808,2.320 0.213,0.151 10 35 5.047,2.169 5.325,2.320 0.277,0.151 10 40 2.193,1.962 2.300,2.113 0.107,0.151 10 0

DTC No. INF Code DTC Detection Condition Trouble Area
P0A37 260 Generator temperature sensor output does not increase in which the value should increase, or output does not decrease under conditions in which the value should decrease.
·

Wire harness or connector

·

Hybrid vehicle generator assembly (Generator temperature sensor)


P0A3A 258 Unusual sudden change in generator temperature sensor output occurs and the condition continues, or unusual sudden change in generator temperature sensor output occurs repeatedly.

CAUTION / NOTICE / HINT

HINT:
·

If DTC P0A37-260 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.

(a)

Drive the vehicle (stop and go driving) on urban roads for approximately 5 minutes.

If the Data List item "Motor Temp No2" shows both increases and decreases in temperature, suspected areas indicated by this DTC are not malfunctioning.


·

If DTC P0A3A-258 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.

(a)

Turn the power switch on (READY) and wait for 30 seconds or more.

(b)

Drive the vehicle for approximately 5 minutes according to the freeze frame data items "Vehicle Spd", "Inverter Coolant Water Temperature", "Motor Temp No1" and "Motor Temp No2".




WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A38-257.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A38-257

PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU (HYBRID VEHICLE CONTROL ECU))

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2C-247

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

2.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
a.

Disconnect the A21 power management control ECU or hybrid vehicle control ECU connector.


b.

POWER MANAGEMENT CONTROL ECU

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A21-26 (GMT) - A21-27 (GMTG) Power switch off 0.3436 to 1442 kΩ




c.

HYBRID VEHICLE CONTROL ECU

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A21-26 (GMT) - A21-27 (GMTG) Power switch off 0.3436 to 1442 kΩ




d.

Reconnect the A21 power management control ECU or hybrid vehicle control ECU connector.



OK

3.CHECK CONNECTOR CONNECTION CONDITION (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR)

NG

7.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
3.CHECK CONNECTOR CONNECTION CONDITION (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2B-250

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

4.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU (HYBRID VEHICLE CONTROL ECU) - ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU (HYBRID VEHICLE CONTROL ECU) - ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR)
a.

Disconnect the DA1 engine room relay block and junction block assembly connector.


b.

Disconnect the A21 power management control ECU or hybrid vehicle control ECU connector.


c.

POWER MANAGEMENT CONTROL ECU

i.

Measure the resistance according to the value(s) in the table below.

HINT:

When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.


Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
DA1-12 (GMT) - A21-26 (GMT) Power switch off Below 1 Ω
DA1-13 (GMTG) - A21-27 (GMTG) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
DA1-12 (GMT) - Other terminals Power switch off 10 kΩ or higher
DA1-13 (GMTG) - Other terminals Power switch off 10 kΩ or higher




d.

HYBRID VEHICLE CONTROL ECU

i.

Measure the resistance according to the value(s) in the table below.

HINT:

When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.


Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
DA1-12 (GMT) - A21-26 (GMT) Power switch off Below 1 Ω
DA1-13 (GMTG) - A21-27 (GMTG) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
DA1-12 (GMT) - Other terminals Power switch off 10 kΩ or higher
DA1-13 (GMTG) - Other terminals Power switch off 10 kΩ or higher




e.

Reconnect the A21 power management control ECU or hybrid vehicle control ECU connector.


f.

Reconnect the DA1 engine room relay block and junction block assembly connector.



OK

5.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR TEMPERATURE SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR TEMPERATURE SENSOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A38-257

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

6.CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR - HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR))

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR - HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR))
a.

Disconnect the DA1 engine room relay block and junction block assembly connector.


b.

Disconnect the D7 hybrid vehicle generator assembly (generator temperature sensor) connector.


c.

Measure the resistance according to the value(s) in the table below.

HINT:

When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.


Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
DA1-12 (GMT) - D7-8 (GMT) Power switch off Below 1 Ω
DA1-13 (GMTG) - D7-4 (GMTG) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
DA1-12 (GMT) - Other terminals Power switch off 10 kΩ or higher
DA1-13 (GMTG) - Other terminals Power switch off 10 kΩ or higher



d.

Reconnect the D7 hybrid vehicle generator assembly (generator temperature sensor) connector.


e.

Reconnect the DA1 engine room relay block and junction block assembly connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
a.

Disconnect the DA1 engine room relay block and junction block assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
DA1-12 (GMT) - DA1-13 (GMTG) Power switch off 0.3436 to 1442 kΩ



c.

Reconnect the DA1 engine room relay block and junction block assembly connector.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

8.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
8.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY (GENERATOR TEMPERATURE SENSOR)

OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG