Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.10–2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A38-257  Generator Temperature Sensor Circuit Low  P0A39-259  Generator Temperature Sensor Circuit High  


DESCRIPTION

Refer to the description for DTC P0A37-260 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A37-260).

DTC No. INF Code DTC Detection Condition Trouble Area
P0A38 257 Short to GND in the generator temperature sensor circuit
·

Wire harness or connector

·

Power management control ECU

·

Hybrid vehicle generator assembly (Generator temperature sensor)


P0A39 259 Open or short to +B in the generator temperature sensor circuit

HINT:

After confirming that DTC P0A38-257 or P0A39-259 is output, use the GTS to check "Motor Temp No2" in the power management control ECU Data List.


Displayed Temperature Malfunction
-40°C (-40°F) Open circuit or short to +B
215°C (419°F) Short circuit or short to GND

WIRING DIAGRAM

A407382E91
2.302,1.917 2.76,2.115 0.458,0.198 10 false 4 1.802,1.938 2.563,2.26 0.76,0.323 10 false GMTG 1.906,1.188 2.667,1.51 0.76,0.323 10 false GMT 2.313,1.188 2.771,1.385 0.458,0.198 10 false 8 0.219,2.583 0.979,2.906 0.76,0.323 10 false D7 0.219,2.781 2.417,3.313 2.198,0.531 10 false Hybrid Vehicle Generator Assembly(Generator Temperature Sensor) 2.542,2.729 4.979,3.573 2.438,0.844 10 false Engine Room Relay Block and Junction Block Assembly Connector 2.552,2.563 3.313,2.885 0.76,0.323 10 false DA1 3.042,1.917 3.802,2.24 0.76,0.323 10 false 13 3.031,1.156 3.792,1.479 0.76,0.323 10 false 12 3.677,1.167 4.438,1.49 0.76,0.323 10 false 12 3.677,1.927 4.438,2.25 0.76,0.323 10 false 13 4.615,1.188 5.375,1.51 0.76,0.323 10 false 26 4.885,1.188 5.646,1.51 0.76,0.323 10 false GMT 4.625,1.948 5.385,2.271 0.76,0.323 10 false 27 4.875,1.938 5.635,2.26 0.76,0.323 10 false GMTG 5.229,2.708 5.99,3.031 0.76,0.323 10 false A21 5.24,2.854 6.49,3.688 1.25,0.833 10 false Power Management Control ECU 5.958,1.302 6.719,1.625 0.76,0.323 10 false ADC 5.563,0.865 6.323,1.188 0.76,0.323 10 false 5V

CAUTION / NOTICE / HINT

HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (IG) and wait for 5 seconds or more.



PROCEDURE

1.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2C-247

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

2.CHECK CONNECTOR CONNECTION CONDITION (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK CONNECTOR CONNECTION CONDITION (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2C-247

Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C


A

3.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR TEMPERATURE SENSOR CONNECTOR)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR TEMPERATURE SENSOR CONNECTOR)
a.

Check the connection condition of the D7 hybrid vehicle generator assembly(generator temperature sensor) connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.


Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C




A

4.READ VALUE USING GTS (MOTOR TEMP NO2)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.READ VALUE USING GTS (MOTOR TEMP NO2)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.


d.

Read the Data List.

Result:
Result Proceed to
-40°C (-40°F) A
215°C (419°F) B
Same as actual temperature C



e.

Turn the power switch off.



A

5.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)

B

7.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
a.
A253109N03
1.583,0.104 1.927,0.344 0.344,0.24 1.625,0.125 1.896,0.313 0.271,0.188 10 true D7

Disconnect the D7 generator temperature sensor connector.


b.
A397757C17
1.469,0.167 1.917,0.417 0.448,0.25 0.948,1.719 1.365,1.302 true 1.792,1.729 1.479,1.094 true 0.552,0.281 0.865,0.438 0.313,0.156 10 false *a 0.813,1.771 1.271,1.969 0.458,0.198 10 false GMT 1.625,1.76 2.083,1.958 0.458,0.198 10 false GMTG 1.542,0.208 2.156,0.406 0.615,0.198 10 false D7
*a Component without harness connected
(Generator Temperature Sensor (Hybrid Vehicle Transaxle Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D7-8 (GMT) - D7-4 (GMTG) Power switch off 0.3436 to 1442 kΩ



c.

Connect the D7 generator temperature sensor connector.



OK

6.INSPECT POWER MANAGEMENT CONTROL ECU

NG

6.INSPECT POWER MANAGEMENT CONTROL ECU
a.
U154409E03
0.635,1.844 1.052,2.479 false 0.594,1.844 0.375,2.479 false 0.667,1.021 0.938,1.188 0.271,0.167 10 false A21 0.135,0.208 0.406,0.375 0.271,0.167 10 false *a 0.917,2.5 1.417,2.667 0.5,0.167 10 false GMT 0.104,2.5 0.604,2.667 0.5,0.167 10 false GMTG

Connect terminals 26 (GMT) and 27 (GMTG) of connector A21 of the power management control ECU.


b.

Connect the GTS to the DLC3.


c.

Turn the power switch on (IG).


d.

Enter the following menus: Powertrain / Hybrid Control / Data List / Motor Temp No2.


e.

Read the Data List.

OK:
Tester Display Condition Specified Condition
Motor Temp No2 Terminals GMT and GMTG connected.
Power switch on (IG)
215°C (419°F)


Text in Illustration
*a Component with harness connected
(Power Management Control ECU)


f.

Turn the power switch off.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

7.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
a.
A253109N03
1.583,0.104 1.927,0.344 0.344,0.24 1.625,0.125 1.896,0.313 0.271,0.188 10 true D7

Disconnect the D7 generator temperature sensor connector.


b.
A397757C17
1.469,0.167 1.917,0.417 0.448,0.25 0.948,1.719 1.365,1.302 true 1.792,1.729 1.479,1.094 true 0.552,0.281 0.865,0.438 0.313,0.156 10 false *a 0.813,1.771 1.271,1.969 0.458,0.198 10 false GMT 1.625,1.76 2.083,1.958 0.458,0.198 10 false GMTG 1.542,0.208 2.156,0.406 0.615,0.198 10 false D7
*a Component without harness connected
(Generator Temperature Sensor (Hybrid Vehicle Transaxle Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D7-8 (GMT) - D7-4 (GMTG) Power switch off 0.3436 to 1442 kΩ



c.

Connect the D7 generator temperature sensor connector.



OK

8.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - GENERATOR TEMPERATURE SENSOR)

NG

8.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - GENERATOR TEMPERATURE SENSOR)
a.

Disconnect the D7 generator temperature sensor connector.


b.

Disconnect the A21 power management control ECU connector.


c.
A379064E01
0.542,0.917 0.917,1.167 0.375,0.25 1.333,3.583 1.75,3.833 0.417,0.25 1.927,1.042 2.406,0.854 false 1.938,1.177 2.427,1.313 false 0.375,4.281 0.594,3.844 false 0.875,4.313 0.635,3.844 false 0.094,0.094 0.521,0.385 0.427,0.292 10 false *a 0.635,0.958 1.063,1.25 0.427,0.292 10 false D7 2.479,0.781 2.99,1.052 0.51,0.271 10 false GMTG 1.406,3.625 1.833,3.917 0.427,0.292 10 false A21 0.104,2 0.531,2.292 0.427,0.292 10 false *b 2.49,1.208 3,1.479 0.51,0.271 10 false GMT 0.76,4.333 1.271,4.604 0.51,0.271 10 false GMT 0.188,4.313 0.698,4.583 0.51,0.271 10 false GMTG

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
D7-8 (GMT) - A21-26 (GMT) Power switch off Below 1 Ω
D7-4 (GMTG) - A21-27 (GMTG) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
D7-8 (GMT) or A21-26 (GMT) - Body ground and other terminals Power switch off 10 kΩ or higher
D7-4 (GMTG) or A21-27 (GMTG) - Body ground and other terminals Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Generator Temperature Sensor)
*b Rear view of wire harness connector
(to Power Management Control ECU)


d.

Reconnect the A21 power management control ECU connector.


e.

Reconnect the D7 generator temperature sensor connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR