Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A92-521  Hybrid Generator Performance  


DESCRIPTION

For a description of MG1 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A90-251).

DTC No. INF Code DTC Detection Condition Trouble Area
P0A92 521 Generator system malfunction
·

Hybrid vehicle generator assembly

·

Generator cable

·

Inverter with converter assembly



CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (READY) with park (P) selected.

2.

With the engine stopped, depress the accelerator pedal and start the engine.

3.

Release the accelerator pedal immediately. (Start and stop the engine several times)



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
DTC P0A92-521 only is output, or DTC other than the one in the table below is also output. A
Following DTC is also output. B


DTC No. Relevant Diagnosis
P31AB-123 Hybrid Battery Cell Low Voltage

HINT:

P0A92-521 may be output due to a malfunction which causes the DTC in the table above to be output. In this case, first troubleshoot the output DTC in the table above. Then, perform a reproduction test to check that no DTCs are output.



e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
DTC P0A92-521 only is output, or DTCs other than the ones in the table below are also output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P06B0-163 Sensor Power Supply "A" Circuit/Open
P06D6-511 Sensor Reference Voltage "F" Circuit/Open
P06E6-164 Sensor Power Supply "C" Circuit/Open
P0A1A-151, 166, 517, 658, 791, 809 Generator Control Module
P0A1B-198, 503, 505, 547, 554, 786, 794, 806 Drive Motor "A" Control Module
P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
P0A3F-243 Drive Motor "A" Position Sensor Circuit
P0A40-500, 504, 506, 549, 556, 808 Drive Motor "A" Position Sensor Circuit Range/Performance
P0A41-245 Drive Motor "A" Position Sensor Circuit Low
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513, 518, 811 Generator Position Sensor Circuit Range/Performance
P0A4D-255 Generator Position Sensor Circuit Low
P0A78-279, 287, 548, 555, 807 Drive Motor "A" Inverter Performance
P0A7A-203, 325, 810 Generator Inverter Performance
P0AA6 (all INF codes)*1 Hybrid Battery Voltage System Isolation Fault
P0BEA-290 Drive Motor "A" Phase V Current Sensor Circuit Range/Performance
P0BEE-298 Drive Motor "A" Phase W Current Sensor Circuit Range/Performance
P0C76-523 Hybrid Battery System Discharge Time Too Long
P0D2E-586 Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
P0D2F-266 Drive Motor "A" Inverter Voltage Sensor Circuit Low
P0D30-267 Drive Motor "A" Inverter Performance
P0E05-328 Generator Phase V Current Sensor Circuit Range/Performance
P0E09-336 Generator Phase W Current Sensor Circuit Range/Performance
P0E32-585 DC/DC Converter Voltage Sensor "A" Range/Performance
P0E33-589 DC/DC Converter Voltage Sensor "A" Low
P0E34-590 DC/DC Converter Voltage Sensor "A" High
P1C2A-155 Generator A/D Converter Circuit
P1C2B-192 Drive Motor "A" A/D Converter Circuit
P1C2D-587 Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
P1C3C-294 Drive Motor "A" Phase V Current Sensor Correlation
P1C3D-302 Drive Motor "A" Phase W Current Sensor Correlation
P1C3E-333 Generator Phase V Current Sensor Correlation
P1C3F-341 Generator Phase W Current Sensor Correlation
P1C4A-288 Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance
P1C4F-296 Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance
P1C54-326 Generator Phase V Current Sensor Sub Circuit Range/Performance
P1C59-334 Generator Phase W Current Sensor Sub Circuit Range/Performance
P1C6D-501 Drive Motor "A" Phase V Current Sensor Offset Range/Performance
P1C6E-502 Drive Motor "A" Phase W Current Sensor Offset Range/Performance
P1C71-515 Generator Phase V Current Sensor Offset Range/Performance
P1C72-516 Generator Phase W Current Sensor Offset Range/Performance
P1C73-512 Sensor Standard Voltage "F" Circuit/Open
P1CA6-156 Generator Control Module Malfunction
P1CA7-193 Drive Motor Control Module Malfunction
P1CAC-200 Generator Position Sensor Angle Malfunction
P1CAD-168 Drive Motor "A" Position Sensor Angle Malfunction
P1CAF-792 Generator Position Sensor REF Signal Cycle Malfunction
P1CB0-795 Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
P1CB2-793 Generator Position Sensor REF Signal Stop Malfunction
P1CB3-796 Drive Motor "A" Position Sensor REF Signal Stop Malfunction
P3004-132 Power Cable Malfunction
P3133-659 Communication Error from Generator to Drive Motor "A"
P3134-661 Communication Error from Drive Motor "A" to Generator
P3233-750 Open or Short to B+ in Blocking of HV Gate Connection

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P0A92-521 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.




e.

Turn the power switch off.



A

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

4.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

NG

CONNECT SECURELY

4.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

A

5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

A

7.CHECK GENERATOR CABLE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY