Refer to the description for DTC P3232-749 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P3232-749).
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P3233 | 750 | Open or short to +B in the emergency shutdown signal line when the IGBTs are operating. | ·
Wire harness or connector ·
Power management control ECU ·
Inverter with converter assembly |
Refer to the wiring diagram for DTC P3232-749 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P3232-749).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 5 seconds or more.
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Disconnect the A22 power management control ECU connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-31 (HSDN) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector
(to Power Management Control ECU) |
Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-31 (HSDN) - A59-31 (HSDN) | Power switch off | Below 1 Ω |
Reconnect the A59 inverter with converter assembly connector.
Reconnect the A22 power management control ECU connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-31 (HSDN) - A59-10 (+B) | Power switch off | 80 Ω or higher |
| A59-31 (HSDN) - A59-9 (+B2) | Power switch off | 80 Ω or higher |
| A59-31 (HSDN) - A59-28 (GND1) | Power switch off | 2.65 to 3.55 kΩ |
| *a | Component without harness connected
(Inverter with Converter Assembly) |
Reconnect the A59 inverter with converter assembly connector.
OK
NG