The inverter with converter assembly (MG ECU) monitors its internal operation and detects the following malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A1A | 200 | The difference between the resolver angle for control and estimated resolver angle exceeds the allowable value. | ·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
| 792 | Resolver REF signal cycle error | ||
| 793 | Resolver REF signal oscillation stop error |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and park (P) selected to start the engine.
Keep the engine running for 5 seconds or more.
Drive the vehicle forward with drive (D) selected for 5 m or more.
Drive the vehicle backward with reverse (R) selected for 5 m or more.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| Only P0A1A-200, 792 or 793 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the D29 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D29-11 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| D29-12 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-7 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| D29-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-10 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| D29-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Turn the power switch off.
Reconnect the D29 inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the D29 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D29-11 (GRF) - D29-12 (GRFG) | Power switch off | 7.1 to 21.6 Ω |
| D29-7 (GSN) - D29-8 (GSNG) | Power switch off | 13.7 to 34.5 Ω |
| D29-10 (GCS) - D29-9 (GCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D29-11 (GRF) or D29-12 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-7 (GSN) or D29-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-10 (GCS) or D29-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Reconnect the D29 inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the D29 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D29-1 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| D29-2 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-3 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| D29-4 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| D29-5 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Turn the power switch off.
Reconnect the D29 inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the D29 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D29-1 (MRF) - D29-2 (MRFG) | Power switch off | 7.1 to 21.6 Ω |
| D29-3 (MSN) - D29-4 (MSNG) | Power switch off | 13.7 to 34.5 Ω |
| D29-6 (MCS) - D29-5 (MCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D29-1 (MRF) or D29-2 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-3 (MSN) or D29-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-6 (MCS) or D29-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Reconnect the D29 inverter with converter assembly connector.
OK
NG
Check the connection of the generator resolver connector.
The connector is connected securely and there are no contact problems.
OK
NG
Check the connection of the motor resolver connector.
The connector is connected securely and there are no contact problems.
OK
NG
Check the connection of the generator resolver connector.
The connector is connected securely and there are no contact problems.
OK
NG
Disconnect the D7 generator resolver connector.
| *a | Component without harness connected
(Generator Resolver (Hybrid Vehicle Transaxle Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D7-1(GRF) - D7-5(GRFG) | Power switch off | 9.5 to 15.5 Ω |
| D7-2(GSN) - D7-6(GSNG) | Power switch off | 15.0 to 27.0 Ω |
| D7-3(GCS) - D7-7(GCSG) | Power switch off | 14.0 to 26.0 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D7-1 (GRF) - Body ground and other terminals (except D7-5 (GRFG)) | Power switch off | 1 MΩ or higher |
| D7-5 (GRFG) - Body ground and other terminals (except D7-1 (GRF)) | Power switch off | 1 MΩ or higher |
| D7-2 (GSN) - Body ground and other terminals (except D7-6 (GSNG)) | Power switch off | 1 MΩ or higher |
| D7-6 (GSNG) - Body ground and other terminals (except D7-2 (GSN)) | Power switch off | 1 MΩ or higher |
| D7-3 (GCS) - Body ground and other terminals (except D7-7 (GCSG)) | Power switch off | 1 MΩ or higher |
| D7-7 (GCSG) - Body ground and other terminals (except D7-3 (GCS)) | Power switch off | 1 MΩ or higher |
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
Connect the D7 generator resolver connector.
OK
NG
Check the connection of the motor resolver connector.
The connector is connected securely and there are no contact problems.
OK
NG
Disconnect the D1 motor resolver connector.
| *a | Component without harness connected
(Motor Resolver (Hybrid Vehicle Transaxle Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D1-3 (MRF) - D1-6 (MRFG) | Power switch off | 9.5 to 15.5 Ω |
| D1-1 (MSN) - D1-4 (MSNG) | Power switch off | 15.0 to 27.0 Ω |
| D1-2 (MCS) - D1-5 (MCSG) | Power switch off | 14.0 to 26.0 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D1-3 (MRF) - Body ground and other terminals (except D1-6 (MRFG)) | Power switch off | 1 MΩ or higher |
| D1-6 (MRFG) - Body ground and other terminals (except D1-3 (MRF)) | Power switch off | 1 MΩ or higher |
| D1-1 (MSN) - Body ground and other terminals (except D1-4 (MSNG)) | Power switch off | 1 MΩ or higher |
| D1-4 (MSNG) - Body ground and other terminals (except D1-1 (MSN)) | Power switch off | 1 MΩ or higher |
| D1-2 (MCS) - Body ground and other terminals (except D1-5 (MCSG)) | Power switch off | 1 MΩ or higher |
| D1-5 (MCSG) - Body ground and other terminals (except D1-2 (MCS)) | Power switch off | 1 MΩ or higher |
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.
Connect the D1 motor resolver connector.
OK
NG