For a description of the inverter (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0D2F-266).
If the motor inverter overheats, has a circuit malfunction, or has an internal short, the inverter transmits this information to the MG ECU via the motor inverter fail signal line.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A78 | 113 | Motor inverter fail signal detection
(System overcurrent) |
·
Hybrid vehicle generator assembly ·
Hybrid vehicle motor assembly ·
Generator cable ·
Motor cable ·
Inverter with converter assembly ·
Power management control ECU ·
PCU fuse ·
Wire harness or connector |
Refer to the wiring diagram for DTC P1CAC-200 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1CAC-200).
Refer to the wiring diagram for DTC P324E-788 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P324E-788).
Refer to the wiring diagram for DTC U0110-159 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>U0110-159).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 5 seconds or more.
Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A78-113 is set before any of the DTCs in the table below are set. | A |
| Any of the DTCs including pending DTCs in the table 1 below are set before P0A78-113 is set. | B |
| Any of the DTCs including pending DTCs in the table 2 below are set before P0A78-113 is set. | C |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P3004-131, 803 | High Voltage Power Resource |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A7F-123 | Hybrid Battery Pack Deterioration |
| P0A80-123 | Replace Hybrid Battery Pack |
| P0A9C-123 | Hybrid Battery Temperature Sensor "A" Range / Performance |
| P0A9D-123 | Hybrid Battery Temperature Sensor "A" Circuit Low |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
| P0AC6-123 | Hybrid Battery Temperature Sensor "B" Range / Performance |
| P0AC7-123 | Hybrid Battery Temperature Sensor "B" Circuit Low |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACB-123 | Hybrid Battery Temperature Sensor "C" Range / Performance |
| P0ACC-123 | Hybrid Battery Temperature Sensor "C" Circuit Low |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AE9-123 | Hybrid Battery Temperature Sensor "D" Range / Performance |
| P0AEA-123 | Hybrid Battery Temperature Sensor "D" Circuit Low |
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P0B10-123 | Hybrid Battery Pack Current Sensor "B" Circuit Low |
| P0B11-123 | Hybrid Battery Pack Current Sensor "B" Circuit High |
| P0B13-123 | Hybrid Battery Pack Current Sensor "A"/"B" Correlation |
| P0BC3-123 | Hybrid Battery Temperature Sensor "E" Range / Performance |
| P0BC4-123 | Hybrid Battery Temperature Sensor "E" Circuit Low |
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High |
| P0C34-123 | Hybrid Battery Temperature Sensor "F" Range / Performance |
| P0C35-123 | Hybrid Battery Temperature Sensor "F" Circuit Low |
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High |
| P3011-123 | Battery Block 1 Becomes Weak |
| P3012-123 | Battery Block 2 Becomes Weak |
| P3013-123 | Battery Block 3 Becomes Weak |
| P3014-123 | Battery Block 4 Becomes Weak |
| P3015-123 | Battery Block 5 Becomes Weak |
| P3016-123 | Battery Block 6 Becomes Weak |
| P3017-123 | Battery Block 7 Becomes Weak |
| P3018-123 | Battery Block 8 Becomes Weak |
| P301A-123 | Open in Hybrid Battery Cell Voltage Detection Circuit |
| P301B-123 | Hybrid Battery Cell Voltage Detection Circuit Range/Performance |
| P3065-123 | Hybrid Battery Temperature Sensor Range/Performance Stuck "A |
| P306A-123 | Hybrid Battery Temperature Sensor Range / Performance Stuck "B" |
| P31AA-123 | Hybrid Battery Cell High Voltage |
| P31AB-123 | Hybrid Battery Cell Low Voltage |
| P31AC-123 | Hybrid Battery Cell Extreme High Voltage |
| P31B3-123 | Hybrid Battery Voltage High |
| U029A-123 | Lost Communication with Hybrid Battery Pack Sensor Module |
Refer to the freeze frame data to determine the order in which the DTCs were set.
P0A78-113 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
C
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A78-202 is not output. | A |
| P0A78-202 is also output. | B |
If P0A78-202 is output, troubleshoot it first. After completing the troubleshooting for P0A78-202, return to perform troubleshooting for this DTC.
Parts repaired or replaced during troubleshooting for P0A78-202 do not need to be re-inspected in this diagnosis procedure.
Turn the power switch off.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
If P0A78-202 was not output in step 2 of this diagnosis procedure, check reference 1 below.
If P0A78-202 was output in step 2 of this diagnosis procedure, repair that DTC first, then check reference 2 below.
| Result | Proceed to |
|---|---|
| Only P0A78-113 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs including pending DTCs in the table 1 and 2 below are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 503, 505, 547, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range/Performance |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range/Performance |
| P0C19-306 | Drive Motor "A" Torque Delivered Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range/Performance |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-803 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| DTC No. | Relevant Diagnosis |
|---|---|
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 166, 517, 658, 791, 809 | Generator Control Module |
| P0A1B-198, 503, 505, 547, 554, 786, 794, 806 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500, 504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513, 518, 811 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 810 | Generator Inverter Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range/Performance |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range/Performance |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range/Performance |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High |
| P0E71-344 | Generator Torque Delivered Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation |
| P1C3E-333 | Generator Phase V Current Sensor Correlation |
| P1C3F-341 | Generator Phase W Current Sensor Correlation |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range/Performance |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range/Performance |
| P1C71-515 | Generator Phase V Current Sensor Offset Range/Performance |
| P1C72-516 | Generator Phase W Current Sensor Offset Range/Performance |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P3004-803 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A78-113 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
T=9.2 N*m (94 kgf*cm, 81 in.*lbf)
Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).
Disconnect the generator cable from the inverter with converter assembly.
Check for arc marks at the bolts and terminals for the generator cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the inverter with converter assembly.
Install the inverter cover.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
T=9.2 N*m (94 kgf*cm, 81 in.*lbf)
Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).
Disconnect the motor cable from the inverter with converter assembly.
Check for arc marks at the bolts and terminals for the motor cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable to the inverter with converter assembly.
Install the inverter cover.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| f1-1 (W) - f1-2 (U) | Power switch off | 89.5 to 98.9 mΩ |
| f1-2 (U) - f1-3 (V) | Power switch off | 89.5 to 98.9 mΩ |
| f1-3 (V) - f1-1 (W) | Power switch off | 89.5 to 98.9 mΩ |
| *1 | Generator Cable
(Inverter with Converter Assembly Side) |
| *2 | Shield Ground |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| f1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the inverter cover.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the generator cable and motor cable from the inverter with converter assembly.
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 (W) - e1-2 (U) | Power switch off | 152.6 to 169.0 mΩ |
| e1-2 (U) - e1-3 (V) | Power switch off | 157.6 to 174.0 mΩ |
| e1-3 (V) - e1-1 (W) | Power switch off | 151.6 to 168.0 mΩ |
| *1 | Motor Cable
(Inverter with Converter Assembly Side) |
| *2 | Shield Ground |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| e1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| e1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the generator cable and motor cable.
Install the inverter cover.
OK
NG
Remove the PCU fuse from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| PCU fuse terminal | Always | Below 1Ω |
| *1 | Engine Room Relay Block and Junction Block Assembly |
| *2 | PCU fuse |
Install the PCU fuse.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-28 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A59-27 (GND2) - Body ground | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-10 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| A59-9 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Disconnect the A22 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-8 (HTM+) - A22-24 (HTM+) | Power switch off | Below 1 Ω |
| A59-18 (HTM-) - A22-25 (HTM-) | Power switch off | Below 1 Ω |
| A59-7 (MTH+) - A22-30 (MTH+) | Power switch off | Below 1 Ω |
| A59-17 (MTH-) - A22-29 (MTH-) | Power switch off | Below 1 Ω |
| A59-6 (REQ+) - A22-33 (REQ+) | Power switch off | Below 1 Ω |
| A59-16 (REQ-) - A22-32 (REQ-) | Power switch off | Below 1 Ω |
| A59-5 (CLK+) - A22-21 (CLK+) | Power switch off | Below 1 Ω |
| A59-15 (CLK-) - A22-20 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-8 (HTM+) or A22-24 (HTM+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-18 (HTM-) or A22-25 (HTM-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-7 (MTH+) or A22-30 (MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-17 (MTH-) or A22-29 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-6 (REQ+) or A22-33 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-16 (REQ-) or A22-32 (REQ-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-5 (CLK+) or A22-21 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A59-15 (CLK-) or A22-20 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector
(to Power Management Control ECU) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-8 (HTM+) or A22-24 (HTM+) - Body ground | Power switch on (IG) | Below 1 V |
| A59-18 (HTM-) or A22-25 (HTM-) - Body ground | Power switch on (IG) | Below 1 V |
| A59-7 (MTH+) or A22-30 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A59-17 (MTH-) or A22-29 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
| A59-6 (REQ+) or A22-33 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A59-16 (REQ-) or A22-32 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
| A59-5 (CLK+) or A22-21 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A59-15 (CLK-) or A22-20 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A22 power management control ECU connector.
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Disconnect the A22 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-24 (HTM+) - A22-25 (HTM-) | Power switch off | 80 to 170 Ω |
| A22-30 (MTH+) - A22-29 (MTH-) | Power switch off | 80 to 170 Ω |
| A22-33 (REQ+) - A22-32 (REQ-) | Power switch off | 80 to 170 Ω |
| A22-21 (CLK+) - A22-20 (CLK-) | Power switch off | 80 to 170 Ω |
| *a | Component without harness connected
(Power Management Control ECU) |
Reconnect the A22 power management control ECU connector.
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-10 (+B) - Body ground | Power switch off | 10 kΩ or higher |
| A59-9 (+B2) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Refer to replace inverter with converter assembly parts (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR).
NEXT
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter with converter assembly.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
T=20 N*m (204 kgf*cm, 15 ft.*lbf)
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
Make sure that the tightening torque of the bolt A is between 16 and 24 N*m (163 and 245 kgf*cm, 12 and 18 ft.*lbf).
Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).
Disconnect the generator cable from the hybrid vehicle transaxle assembly.
Check for arc marks at the bolts and terminals for the generator cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the generator cable to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the generator cable.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| f1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Generator Cable
(Inverter with Converter Assembly Side) |
| *2 | Generator Cable
(Hybrid Vehicle Transaxle Assembly Side) |
| *3 | Shield ground |
Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| f1-1 (W) - f2-3 (W) | Power switch off | Below 1 Ω |
| f1-2 (U) - f2-2 (U) | Power switch off | Below 1 Ω |
| f1-3 (V) - f2-1 (V) | Power switch off | Below 1 Ω |
| f1-1 (W) - f2-2 (U) | Power switch off | 100 MΩ or higher |
| f1-2 (U) - f2-1 (V) | Power switch off | 100 MΩ or higher |
| f1-3 (V) - f2-3 (W) | Power switch off | 100 MΩ or higher |
Install the generator cable.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
Make sure that the tightening torque of the bolts is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).
Disconnect the motor cable from the hybrid vehicle transaxle assembly.
Check for arc marks at the bolts and terminals for the motor cable.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable to the hybrid vehicle transaxle assembly.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| e1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| e1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Motor Cable
(Inverter with Converter Assembly Side) |
| *2 | Motor Cable
(Hybrid Vehicle Transaxle Assembly Side) |
| *3 | Shield ground |
Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 (W) - e2-1 (W) | Power switch off | Below 1 Ω |
| e1-2 (U) - e2-3 (U) | Power switch off | Below 1 Ω |
| e1-3 (V) - e2-2 (V) | Power switch off | Below 1 Ω |
| e1-1 (W) - e2-3 (U) | Power switch off | 100 MΩ or higher |
| e1-2 (U) - e2-2 (V) | Power switch off | 100 MΩ or higher |
| e1-3 (V) - e2-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
OK
NG