Refer to the description for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0AE2 | 773 | SMRP on the HV battery positive side stuck closed | ·
Hybrid battery junction block assembly ·
Inverter with converter assembly ·
Power management control ECU ·
Wire harness and connector |
Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).
When performing P0AE2-773 troubleshooting, use either a tool wrapped with vinyl insulation tape or an insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If the DTCs are cleared or the cable is disconnected and reconnected to the negative (-) auxiliary battery terminal before performing repairs, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY).
After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
Turn the power switch off and wait for 60 seconds or more.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| DTC P0E2-773 only is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793 | Generator Control Module |
| P0A1B-163, 164, 168, 193, 511, 512, 661, 786, 794, 795, 796 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-442 | DC / DC Converter Performance |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AA4-232 | Hybrid Battery Negative Contactor Circuit Stuck Closed |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P2511-149 | HV CPU Power Relay Sensor Circuit Intermittent No Continuity |
| P3004-132 | High Voltage Power Resource |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0AE2-773 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read the freeze frame data of DTC P0AE2-773.
| Result | Proceed to |
|---|---|
| VL-Voltage before Boosting is 60 V or more. | A |
| VL-Voltage before Boosting is below 60 V. | B |
Turn the power switch off.
A
B
OK
NG
NEXT
A
B
C
NEXT
NEXT
OK
NG
NEXT
OK
NG
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Disconnect the c6 hybrid battery junction block assembly connector.
Disconnect the L5 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-3 (SMRP) - c6-3 (SMRP) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-3 (SMRP) and c6-3 (SMRP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| *b | Rear view of wire harness connector
(to Hybrid Battery Junction Block Assembly) |
Reconnect the L5 power management control ECU connector.
Reconnect the c6 hybrid battery junction block assembly connector.
Install the No. 2 hybrid battery shield sub-assembly.
OK
NG
NEXT
OK
NG
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Disconnect the c6 hybrid battery junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c6-3 (SMRP) - c6-2 (GND) | -40 to 80 °C (-40 to 176°F) | 112 to 274 Ω |
| *a | Component without harness connected
(Hybrid Battery Junction Block Assembly) |
Reconnect the c6 hybrid battery junction block assembly connector.
Install the No. 2 hybrid battery shield sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).
Disconnect the high voltage cable connectors from the hybrid battery junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T5-1 (CEI) - h3-1 (-) | Power switch off | 10 kΩ or higher |
If a system main relay is stuck closed, inspect the HV relay assembly without removing it from the vehicle, in order to keep the relay closed.
If the result of reading the freeze frame data is A, the hybrid battery junction block assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
Connect the high voltage cable connectors.
Install the No. 2 hybrid battery shield sub-assembly.
OK
NG
NEXT
A
B