Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.10–2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P314A-828  Inverter Coolant Pump Speed Signal  


DESCRIPTION

Refer to the description for DTC P0C73-776 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776).

The inverter water pump assembly sends the water pump speed (measured value) signal to the power management control ECU. If the water pump speed (measured value) signal is not sent to the power management control ECU when the power switch is on (READY), this DTC is stored.

DTC No. INF Code DTC Detection Condition Trouble Area
P314A 828
When either of the following conditions is met:
·

A malfunction in the power source circuit or water pump speed signal line of the inverter water pump assembly is detected.

·

A malfunction in the power source circuit of the inverter water pump assembly or power management control ECU is detected.


(1 trip detection logic)
·

Wire harness or connector

·

Power management control ECU

·

Inverter water pump assembly

·

IGCT No. 3 fuse

·

IGCT relay



Related Data List
DTC No. INF Code Data List Item
P314A 828
·

Inverter W/P Revolution*1

·

W/P Run Control Duty*1

·

Ready Signal



*1: This Data List item is related to the inverter water pump assembly.

Related Active Test
DTC No. INF Code Active Test
P314A 828 Activate the Water Pump*2

*2: This is an Active Test of the inverter water pump assembly.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0C73-776 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776).

CAUTION / NOTICE / HINT

HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the power switch on (READY) and wait for 120 seconds or more.



PROCEDURE

1.CLEAR DTC

NEXT

2.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE WATER PUMP)
2.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE WATER PUMP)
NOTICE:

Be sure to perform the inspection with the auxiliary battery voltage at 12 V or more.


HINT:

When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.


d.

Perform the Activate the Water Pump Active Test.


e.

Touch the inverter water pump assembly and check that it is operating (vibrating).

OK:

The inverter water pump is operating (vibrating).



f.

Turn the power switch off.



OK

3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

NG

9.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
3.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)

NG

CONNECT SECURELY

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)

OK

5.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP ASSEMBLY)

NG

CONNECT SECURELY

5.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WATER PUMP ASSEMBLY)
a.

Disconnect the A21 power management control ECU connector.


b.

Disconnect the g1 inverter water pump assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

U154262E03
1.333,2.292 1.01,2.656 true 5.177,1.542 4.854,1.958 true 0.771,2.677 1.198,2.875 0.427,0.198 10 false NIWP 1.323,2.927 1.594,3.094 0.271,0.167 10 false A21 4.688,1.969 5.073,2.167 0.385,0.198 10 false NWP 0.396,0.531 0.604,0.698 0.208,0.167 10 false *a 4.427,0.531 4.635,0.698 0.208,0.167 10 false *b 6.115,1.396 6.292,1.677 0.177,0.281 10 false g1

Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)
*b Front view of wire harness connector
(to Inverter Water Pump Assembly)

Standard Resistance:
Tester Connection Condition Specified Condition
g1-2 (NWP) - A21-14 (NIWP) Power switch off Below 1 Ω
g1-2 (NWP) or A21-14 (NIWP) -Body ground and other terminals Power switch off 10 kΩ or higher


HINT:

Check the condition (looseness, deterioration, etc.) of the wire to body ground for the inverter water pump assembly.



d.

Reconnect the A21 power management control ECU connector.


e.

Reconnect the g1 inverter water pump assembly connector.



OK

6.CHECK POWER MANAGEMENT CONTROL ECU

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK POWER MANAGEMENT CONTROL ECU
a.

Disconnect the g1 inverter water pump assembly connector.


b.

Turn the power switch on (IG).


c.
U154410E04
1.833,1.698 2.198,2.365 true 0.729,1.781 1.052,2.385 true 1.958,0.99 2.146,1.156 0.188,0.167 10 false L5 0.646,0.99 0.927,1.156 0.281,0.167 10 false A21 0.177,0.188 0.448,0.354 0.271,0.167 10 false *a 2.208,2.385 2.51,2.552 0.302,0.167 10 false E1 0.865,2.385 1.281,2.552 0.417,0.167 10 false NIWP

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A21-14 (NIWP) - L5-6 (E1) Power switch on (IG) 11 to 14 V


Text in Illustration
*a Component with harness connected
(Power Management Control ECU)


d.

Turn the power switch off.


e.

Reconnect the g1 inverter water pump assembly connector.



OK

7.CLEAR DTC

NG

7.CLEAR DTC

NEXT

8.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE WATER PUMP)
8.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE WATER PUMP)
NOTICE:

Be sure to perform the inspection with the auxiliary battery voltage at 12 V or more.


HINT:

When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.


d.

Perform the "Activate the Water Pump" Active Test.


e.
U154489E03
1.76,1.177 2.063,1.75 true 0.823,1.24 0.583,1.76 true 0.177,0.135 0.406,0.333 0.229,0.198 10 false *a 2,1.781 2.198,1.979 0.198,0.198 10 false E1 2.802,3.323 3.156,3.521 0.354,0.198 10 false GND 0.75,0.552 1.021,0.719 0.271,0.167 10 false A21 1.896,0.563 2.094,0.729 0.198,0.167 10 false L5 0.375,1.781 0.771,1.958 0.396,0.177 10 false NIWP 1.438,3.635 1.563,3.781 0.125,0.146 10 true A

Connect an oscilloscope between the power management control ECU terminals specified in the table below, and measure the waveform.

Item Content
Terminal A21-14 (NIWP) - L5-6 (E1)
Equipment Setting 5 V/DIV., 100 ms./DIV.
Condition Power switch on (IG), during Active Test

OK:

The duration of wavelength A is 300 msec or less.


Text in Illustration
*a Component with harness connected
(Power Management Control ECU)


f.

Turn the power switch off.



OK

NG

9.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)

OK

10.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - IGCT RELAY)

NG

12.CHECK FUSE (IGCT NO. 3)
10.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - IGCT RELAY)
a.

Remove the IGCT relay from the engine room relay block and junction block assembly.


b.

Disconnect connector g1 from the inverter water pump assembly.


c.

While slightly shaking the wire harness, connector and engine room relay block and junction block assembly, measure the resistance according to the value(s) in the table below.

U154496E02
2.073,1.479 2.188,1.979 false 0.896,1.344 1.115,1.573 0.219,0.229 10 false g1 0.781,0.354 1.052,0.563 0.271,0.208 10 false *a 3.469,0 3.74,0.208 0.271,0.208 10 false *1 5.708,1.844 5.979,2.052 0.271,0.208 10 false *2 2,2 2.615,2.271 0.615,0.271 10 false +BWP

Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly *2 IGCT Relay
*a Front view of wire harness connector
(to Inverter Water Pump Assembly)
- -

Standard Resistance:
Tester Connection Switch Condition Specified Condition
5 (IGCT relay) - g1-4 (+BWP) Power switch off Below 1 Ω


HINT:
A288054E02
0.139,0.08 0.359,0.293 0.220,0.213 10 *a 0.92,1.316 1.141,1.529 0.220,0.213 10 *b 1.438,2.647 1.659,2.860 0.220,0.213 10 *c

·

Connectors

Slightly shake the connector vertically and horizontally.

·

Wire Harness

Slightly shake the wire harness vertically and horizontally.

The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.

·

Engine Room Relay Block and Junction Block Assembly

Apply slight vibration with a finger to the engine room relay block and junction block assembly and check whether a malfunction occurs.



Text in Illustration
*a Example
*b Shake Slightly
*c Vibrate Slightly

NOTICE:

Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.



d.

Install the IGCT relay.


e.

Connect the inverter water pump assembly connector.



OK

11.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)

NG

13.CHECK INSTALLATION CONDITION (IGCT NO. 3 FUSE)
11.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
a.

Disconnect connector g1 from the inverter water pump assembly.


b.
U154490E03
0.833,2.521 1.354,1.896 false 1.615,1.125 1.875,1.302 0.26,0.177 10 false g1 0.281,0.219 0.5,0.417 0.219,0.198 10 false *a 0.49,2.458 0.865,2.656 0.375,0.198 10 false GND

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
g1-1 (GND) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Inverter Water Pump Assembly)


c.

Connect the inverter water pump assembly connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

12.CHECK FUSE (IGCT NO. 3)
a.
A270315E02
0.146,0.152 0.388,0.393 0.242,0.242 10 *1 2.973,0.572 3.214,0.814 0.242,0.242 10 *2 2.329,0.96 2.951,0.679 false

Remove the IGCT No. 3 fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
IGCT No. 3 fuse Always Below 1Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 IGCT No. 3 Fuse


c.

Install the IGCT No. 3 fuse.



OK

CONNECT SECURELY (INVERTER WATER PUMP ASSEMBLY CONNECTOR)

NG

23.CONNECT SECURELY
13.CHECK INSTALLATION CONDITION (IGCT NO. 3 FUSE)
a.

Check installation condition of the IGCT No. 3 fuse.

OK:

IGCT No. 3 fuse is installed correctly.




OK

14.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)

NG

16.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
14.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)
a.

Remove the IGCT No. 3 fuse from the engine room relay block and junction block assembly.


b.

Remove the IGCT relay from the engine room relay block and junction block assembly.


c.

Disconnect connector g1 from the inverter water pump assembly.


d.

Measure the resistance according to the value(s) in the table below.

U154497E02
2.25,1.563 2.385,2.021 false 1.031,1.469 1.24,1.635 0.208,0.167 10 false g1 1.135,0.479 1.375,0.708 0.24,0.229 10 false *a 3.656,0.052 3.896,0.281 0.24,0.229 10 false *1 5.771,0.177 6.01,0.406 0.24,0.229 10 false *2 5.813,1.917 6.052,2.146 0.24,0.229 10 false *3 2.25,2.052 2.781,2.344 0.531,0.292 10 false +BWP

Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly *2 IGCT No. 3 Fuse
*3 IGCT Relay - -
*a Front view of wire harness connector
(to Inverter Water Pump Assembly)
- -

Standard Resistance:
Tester Connection Switch Condition Specified Condition
2 (IGCT No. 3 fuse) - g1-4 (+BWP) Power switch off Below 1 Ω
1 (IGCT No. 3 fuse) - 5 (IGCT relay) Power switch off Below 1 Ω
2 (IGCT No. 3 fuse) or g1-4 (+BWP) - Body ground and other terminals Power switch off 10 kΩ or higher


NOTICE:

Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.



e.

Install the IGCT No. 3 fuse.


f.

Install the IGCT relay.


g.

Connect the inverter water pump assembly connector.



OK

15.CHECK FUSE (IGCT NO. 3)

NG

18.CHECK FUSE (IGCT NO. 3)
15.CHECK FUSE (IGCT NO. 3)
a.
A270315E02
0.146,0.152 0.388,0.393 0.242,0.242 10 *1 2.973,0.572 3.214,0.814 0.242,0.242 10 *2 2.329,0.96 2.951,0.679 false

Remove the IGCT No. 3 fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
IGCT No. 3 fuse Always Below 1Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 IGCT No. 3 Fuse


c.

Install the IGCT No. 3 fuse.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINALS)

NG

19.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
16.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
a.

Check the terminals of the IGCT No. 3 fuse holder.

OK:

The terminals of the IGCT No. 3 fuse holder are not bent, loose or corroded.




OK

17.CHECK FUSE (IGCT NO. 3)

NG

22.CHECK FUSE (IGCT NO. 3)
17.CHECK FUSE (IGCT NO. 3)
a.
A270315E02
0.146,0.152 0.388,0.393 0.242,0.242 10 *1 2.973,0.572 3.214,0.814 0.242,0.242 10 *2 2.329,0.96 2.951,0.679 false

Remove the IGCT No. 3 fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
IGCT No. 3 fuse Always Below 1Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 IGCT No. 3 Fuse


c.

Install the IGCT No. 3 fuse.



OK

CONNECT SECURELY (IGCT NO. 3 FUSE)

NG

REPLACE FUSE (IGCT NO. 3)

18.CHECK FUSE (IGCT NO. 3)
a.
A270315E02
0.146,0.152 0.388,0.393 0.242,0.242 10 *1 2.973,0.572 3.214,0.814 0.242,0.242 10 *2 2.329,0.96 2.951,0.679 false

Remove the IGCT No. 3 fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
IGCT No. 3 fuse Always Below 1Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 IGCT No. 3 Fuse


c.

Install the IGCT No. 3 fuse.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

24.REPAIR OR REPLACE HARNESS OR CONNECTOR
19.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
a.

Disconnect connector g1 from the inverter water pump assembly.


b.
U154490E03
0.833,2.521 1.354,1.896 false 1.615,1.125 1.875,1.302 0.26,0.177 10 false g1 0.281,0.219 0.5,0.417 0.219,0.198 10 false *a 0.49,2.458 0.865,2.656 0.375,0.198 10 false GND

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
g1-1 (GND) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Inverter Water Pump Assembly)


c.

Connect the inverter water pump assembly connector.



OK

20.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)

NG

24.REPAIR OR REPLACE HARNESS OR CONNECTOR
20.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
a.

Check the terminals of the IGCT No. 3 fuse holder.

OK:

The terminals of the IGCT No. 3 fuse holder are not bent, loose or corroded.




OK

21.REPLACE INVERTER WATER PUMP ASSEMBLY

NG

25.REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINALS)
21.REPLACE INVERTER WATER PUMP ASSEMBLY

NEXT

REPLACE FUSE (IGCT NO. 3)

22.CHECK FUSE (IGCT NO. 3)
a.
A270315E02
0.146,0.152 0.388,0.393 0.242,0.242 10 *1 2.973,0.572 3.214,0.814 0.242,0.242 10 *2 2.329,0.96 2.951,0.679 false

Remove the IGCT No. 3 fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
IGCT No. 3 fuse Always Below 1Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 IGCT No. 3 Fuse


c.

Install the IGCT No. 3 fuse.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINALS)

NG

25.REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINALS)
23.CONNECT SECURELY
a.

Connect the inverter water pump assembly connector securely.



NEXT

REPLACE FUSE (IGCT NO. 3)

24.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (IGCT NO. 3)

25.REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINALS)

NEXT

REPLACE FUSE (IGCT NO. 3)