Refer to the description for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A09 | 265 | Open or GND short in NODD signal circuit of DC/DC converter | ·
Wire harness or connector ·
Inverter with converter assembly ·
Power management control ECU |
Refer to the wiring diagram for DTC P0A08-264 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A08-264).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 10 seconds or more.
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-1 (IGCT) - Body ground | Power switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turning the power switch on (IG) with the inverter with converter assembly connector connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
As there might be an intermittent malfunction in the inverter with converter assembly power source circuit, inspect the following even if the measured voltage is as specified:
Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)
Fuse condition (before and after removing fuse(s)) (IGCT circuit)
Connection condition of connectors (IGCT circuit)
Wire harness condition (IGCT circuit)
Wire harness condition (GND circuit)
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Turn the power switch off.
NEXT
Connect the GTS to the DLC3.
Depress the brake pedal and turn the power switch on (READY).
Perform this step to check if the power switch on can be turned ON (READY).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| Power switch cannot be turned ON (READY) and P0A09-265 is output. | A |
| Power switch can be turned ON (READY) and P0A09-265 is not output. | B |
Turn the power switch off.
A
B
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Disconnect the A21 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-12 (NODD) - A21-21 (NODD) | Power switch off | Below 1 Ω |
| A59-12 (NODD) or A21-21 (NODD) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector
(to Power Management Control ECU) |
Reconnect the A59 inverter with converter assembly connector.
Reconnect the A21 power management control ECU connector.
OK
NG