Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A95-123  High Voltage Fuse  


DESCRIPTION

DTC No. INF Code DTC Detection Condition Trouble Area
P0A95 123 Voltage between VA28 and GA2 terminals is below the standard despite the interlock switch being engaged (1 trip detection)
·

Service plug grip

·

HV battery

·

Hybrid battery junction block assembly

·

Inverter with converter assembly



WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).

A219393E15
1.281,1.646 0.948,1.833 0.948,1.833 0.948,1.938 false 0.583,1.958 1.365,2.458 0.781,0.5 10 false Service Plug Grip 4.99,0.75 5.396,1.063 0.406,0.313 10 false GA2 4.99,1.74 5.396,2.052 0.406,0.313 10 false VA28 4.677,0.552 4.948,0.781 0.271,0.229 10 false 11 4.729,1.552 4.896,1.781 0.167,0.229 10 false 5 4.906,2.292 6.125,2.604 1.219,0.313 10 false Battery Smart Unit 2.365,2.344 3.063,2.698 0.698,0.354 10 false HV Battery 1.458,0.083 1.625,0.25 0.167,0.167 10 false + 1.469,2.323 1.635,2.49 0.167,0.167 10 false - 4.656,0.74 4.927,0.969 0.271,0.229 10 false z30 4.646,1.729 4.917,1.958 0.271,0.229 10 false z33

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

2.CHECK HV BATTERY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
U190654E02
1.521,0.823 1.708,0.979 0.188,0.156 10 false k3 1.208,1.51 1.417,1.667 0.208,0.156 10 false h3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
k3-1 (+) - h3-1 (-) Power switch off 10 kΩ or higher



d.

Install the No. 2 hybrid battery shield sub-assembly.



OK

3.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

5.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP, SMRB, SMRG)
3.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
U190703E02
2.271,1.333 2.573,0.844 true 2.292,1.521 2.781,0.979 true 1.729,1.146 1.99,1.302 0.26,0.156 10 false T6 2.49,0.656 2.75,0.813 0.26,0.156 10 false CBI 2.823,0.854 3.083,1.01 0.26,0.156 10 true CEI 1.75,1.719 2.01,1.875 0.26,0.156 10 false T5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T6-1 (CBI) - T5-1 (CEI) Power switch off 10 kΩ or higher



d.

Install the No. 2 hybrid battery shield sub-assembly.



OK

4.INSPECT SERVICE PLUG GRIP

NG

11.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
4.INSPECT SERVICE PLUG GRIP
a.

Disconnect the cable from the negative (-) auxiliary battery terminal.



c.
A212489

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Standard Resistance
Service plug grip Always Below 1 Ω



d.

Reconnect the cable to the negative (-) auxiliary battery terminal.



OK

NG

5.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP, SMRB, SMRG)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
U190658E02
1.823,0.979 2.083,1.156 0.26,0.177 10 false T6 1.292,0.646 1.552,0.823 0.26,0.177 10 false k3

Measure the resistance according to the value(s) in the table below.

Standard Resistance (SMRB):
Tester Connection Condition Specified Condition
T6-1 (CBI) - k3-1 (+) Power switch off 10 kΩ or higher



HINT:

If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.


d.
U190657E02
0.26,1.365 0.521,1.542 0.26,0.177 10 false h3 1.719,1.75 1.979,1.927 0.26,0.177 10 false T5

Measure the resistance according to the value(s) in the table below.

Standard Resistance (SMRG):
Tester Connection Condition Specified Condition
T5-1 (CEI) - h3-1 (-) Power switch off 10 kΩ or higher



HINT:
·

If a system main relay is stuck closed, inspect the hybrid battery junction block assembly without removing it from the vehicle, in order to keep the relay closed.

·

If the resistance is between 28.5 and 31.5 Ω, it can be determined that SMRP is stuck closed.



e.

Install the No. 2 hybrid battery shield sub-assembly.



OK

6.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

NG

8.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
6.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
U190654E02
1.521,0.823 1.708,0.979 0.188,0.156 10 false k3 1.208,1.51 1.417,1.667 0.208,0.156 10 false h3

Disconnect the k3 and h3 hybrid battery junction block assembly connectors.


d.
U190655E02
1.615,1.156 1.802,1.313 0.188,0.156 10 false k3 0.99,1.75 1.198,1.906 0.208,0.156 10 false h3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
k3-1 (+) - h3-1 (-) Power switch off 10 kΩ or higher



e.

Reconnect the k3 and h3 hybrid battery junction block assembly connectors.


f.

Install the No. 2 hybrid battery shield sub-assembly.



OK

NG

7.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
7.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

NEXT

8.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

NEXT

9.CHECK INVERTER WITH CONVERTER ASSEMBLY
9.CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
A252586

Disconnect the frame wire.


d.
U190692E02
1.125,0.958 0.771,0.844 true 1.271,0.729 0.99,0.573 true 1.177,0.135 1.448,0.313 0.271,0.177 10 false T6 0.542,1.177 0.813,1.354 0.271,0.177 10 false T5 0.74,0.479 1.021,0.667 0.281,0.188 10 false CBI 0.521,0.74 0.802,0.927 0.281,0.188 10 false CEI

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T6-1 (CBI) - T5-1 (CEI) Power switch off 10 kΩ or higher



e.

Connect the frame wire.


f.

Install the No. 2 hybrid battery shield sub-assembly.



OK

NG

10.REPLACE INVERTER WITH CONVERTER ASSEMBLY
11.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
A252586

Disconnect the frame wire.


d.
A253665

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T6-1 (CBI) - T5-1 (CEI) Power switch off 10 kΩ or higher



e.

Connect the frame wire.


f.

Install the No. 2 hybrid battery shield sub-assembly.



OK

12.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

13.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
13.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

NEXT