Refer to the description for DTC P0A9C-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A9C-123).
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A9D
P0A9E P0AC7 P0AC8 P0ACC P0ACD P0AEA P0AEB P0BC4 P0BC5 P0C35 P0C36 |
123 | When the temperature of the battery temperature sensor is less than the standard value (open) or higher than the standard value (shorted) (1 trip detection). | ·
HV battery ·
Battery smart unit ·
Wire harness or connector ·
Hybrid battery junction block assembly |
After checking for the above DTCs, check the hybrid system Data List item "Temp of Batt" using the GTS.
| Temperature Displayed | Malfunction |
|---|---|
| Below -45°C (-49°F) | Open or +B short circuit |
| 95°C (203°F) or more | GND short circuit |
Refer to the wiring diagram for DTC P0A9C-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A9C-123).
Refer to the wiring diagram for DTC P0ABF-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0ABF-123).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
If a short to +B occurs in the battery temperature sensor, battery current sensor or intake air temperature sensor, the following DTCs may be output simultaneously.
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High |
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High |
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High |
| P0AAF-123 | Hybrid Battery Pack Air Temperature Sensor "A" Circuit High |
| P0AB4-123 | Hybrid Battery Pack Air Temperature Sensor "B" Circuit High |
A
B
A
B
Connect the GTS to the DLC3.
Enter the following menus: Powertrain / Hybrid Control / Data List / Temp of Batt TB 1 to 6.
Compare the temperature of the 6 battery temperature sensors to determine the sensor with the malfunction (Temp of Batt TB1 to TB6).
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Check the connections of the z24 connector of the battery smart unit.
The connectors are connected securely and there are no contact problems.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z24-24 (VIB) - z24-12 (GIB) | Power switch on (IG) | 4.6 to 5.4 V |
| *a | Component with harness connected
(Battery Smart Unit) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Disconnect the z25 hybrid battery junction block assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z25-1 (VIB) - z25-3 (GIB) | Power switch on (IG) | 4.6 to 5.4 V |
| *a | Front view of wire harness connector
(to Hybrid Battery Junction Block Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the z25 hybrid battery junction block assembly connector.
Install the No. 2 hybrid battery shield sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Disconnect the z25 hybrid battery junction block assembly connector.
Disconnect the z24 battery smart unit connector.
Measure the resistance according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z24-11 (IB1) - z25- 2 (IB1) | Power switch off | Below 1 Ω |
| z24-12 (GIB) - z25- 3 (GIB) | Power switch off | Below 1 Ω |
| z24-23 (IB0) - z25- 4 (IB0) | Power switch off | Below 1 Ω |
| z24-24 (VIB) - z25- 1 (VIB) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z24-11 (IB1) or z25- 2 (IB1) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| z24-12 (GIB) or z25- 3 (GIB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| z24-23 (IB0) or z25- 4 (IB0) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| z24-24 (VIB) or z25- 1 (VIB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
| *b | Front view of wire harness connector
(to Hybrid Battery Junction Block Assembly) |
Reconnect the z25 hybrid battery junction block assembly connector.
Reconnect the z24 battery smart unit connector.
Install the No. 2 hybrid battery shield sub-assembly.
OK