Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A80-123  Replace Hybrid Battery Pack  


DESCRIPTION

The HV battery uses lithium-ion batteries and does not require external charging. The hybrid vehicle control ECU controls the SOC (state of charge) of the HV battery at a constant level during driving. The HV battery is composed of 56 modules, and each module consists of seven 3.6 V cells in series. The battery smart unit monitors battery block voltage at 7 locations.

A251036E02
3.094,0.646 3.354,0.198 3.354,0.198 3.615,0.198 false 3.677,0.146 4.854,0.458 1.177,0.313 10 false Battery Block 0.219,0.104 0.969,0.302 0.75,0.198 10 false HV Battery 2.583,3.208 4.698,3.51 2.115,0.302 10 false Battery Smart Unit 0.448,2.99 0.885,3.323 0.438,0.333 10 false GA0 0.74,2.99 1.125,3.302 0.385,0.313 10 false VA1 1.177,2.99 1.667,3.354 0.49,0.365 10 false VA2 1.677,2.979 2.146,3.281 0.469,0.302 10 false VA3 2.146,2.99 2.531,3.313 0.385,0.323 10 false VA4 6.042,2.99 6.583,3.323 0.542,0.333 10 false VA56 5.656,2.99 6.208,3.313 0.552,0.323 10 false VA55 5.219,2.99 5.708,3.313 0.49,0.323 10 false VA54 4.052,2.99 4.385,3.208 0.333,0.219 10 false VA8 3.573,2.99 3.906,3.208 0.333,0.219 10 false VA7 3.104,2.99 3.438,3.208 0.333,0.219 10 false VA6 2.625,2.979 2.958,3.198 0.333,0.219 10 false VA5

A309448E03
2.771,3.406 4.229,3.594 1.458,0.188 10 false Connected to circuit A 2.771,2.542 4.229,2.729 1.458,0.188 10 false Connected to circuit A 2.771,2.26 4.229,2.448 1.458,0.188 10 false Connected to circuit A 2.771,1.396 4.229,1.583 1.458,0.188 10 false Connected to circuit A 2.771,3.115 4.229,3.302 1.458,0.188 10 false Connected to circuit B 2.771,2.823 4.229,3.01 1.458,0.188 10 false Connected to circuit B 2.771,1.958 4.229,2.146 1.458,0.188 10 false Connected to circuit B 2.771,1.677 4.229,1.865 1.458,0.188 10 false Connected to circuit B 2.906,3.833 5.042,4.021 2.135,0.188 10 false Voltage detection relay circuit 3.75,4.281 5.042,4.469 1.292,0.188 10 false Battery Smart Unit 0.729,3.385 1.177,3.573 0.448,0.188 10 false VB1 0.729,3.104 1.26,3.292 0.531,0.188 10 false VB2 0.729,2.833 1.198,3.021 0.469,0.188 10 false VB3 0.729,2.531 1.281,2.719 0.552,0.188 10 false VB4 0.729,2.26 1.302,2.448 0.573,0.188 10 false VB5 0.729,1.406 1.229,1.594 0.5,0.188 10 false VB8 0.729,1.688 1.396,1.875 0.667,0.188 10 false VB7 0.729,1.99 1.25,2.177 0.521,0.188 10 false VB6 4.292,2.167 4.969,2.354 0.677,0.188 10 false Circuit A 4.292,2.49 4.969,2.677 0.677,0.188 10 false Circuit B 5.5,2.792 6.625,3.219 1.125,0.427 10 false Analogue / Digital Converter Circuit

DTC No. INF Code DTC Detection Condition Trouble Area
P0A80 123
·

Battery cell internal resistance value is out of the standard range (1 trip detection)

·

Difference between each HV battery block capacity is larger than the standard (1 trip detection)

·

Differences in voltage between each battery block when the power switch is on (IG) and off is larger than the standard (2 trip detection)


·

HV battery

·

Battery smart unit



HINT:
·

P0A80-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)

·

DTC P0A80-123 is stored when a malfunction is detected in the HV battery or battery smart unit. If the HV supply battery is malfunctioning, the malfunction may not be reproduced when the condition of HV supply battery changes due to difference in the driving load (amperage), battery SOC and battery temperature. Therefore, use the freeze frame data when performing a repair.

·

In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary:

-

Make sure the air intake port is not blocked.

-

Make sure there are no gaps between the connecting parts of the ducts.





CAUTION / NOTICE / HINT

CAUTION:
·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)

A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)

A

3.CHECK FREEZE FRAME DATA

B

3.CHECK FREEZE FRAME DATA
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read output DTCs.


e.

Using the GTS, make a note of the freeze frame data item "Battery Block Vol -V01 to V08".


f.

Compare the freeze frame data item "Battery Block Vol -V01 to V08" values with those shown in the following combination tables.


Table 1
Circuit A Battery Block Circuit B Battery Block Condition
Battery Block Vol-V01 (VB1) Battery Block Vol-V02 (VB2) "Battery Block Vol - V01" - "Battery Block Vol - V02" = 0.6 V or more
Battery Block Vol-V04 (VB4) Battery Block Vol-V03 (VB3) "Battery Block Vol - V04" - "Battery Block Vol - V03" = 0.6 V or more
Battery Block Vol-V05 (VB5) Battery Block Vol-V06 (VB6) "Battery Block Vol - V05" - "Battery Block Vol - V06" = 0.6 V or more
Battery Block Vol-V08 (VB8) Battery Block Vol-V07 (VB7) "Battery Block Vol - V08" - "Battery Block Vol - V07" = 0.6 V or more

Table 2
Circuit A Battery Block Circuit B Battery Block Condition
Battery Block Vol-V01 (VB1) Battery Block Vol-V02 (VB2) "Battery Block Vol - V02" - "Battery Block Vol - V01" = 0.6 V or more
Battery Block Vol-V04 (VB4) Battery Block Vol-V03 (VB3) "Battery Block Vol - V03" - "Battery Block Vol - V04" = 0.6 V or more
Battery Block Vol-V05 (VB5) Battery Block Vol-V06 (VB6) "Battery Block Vol - V06" - "Battery Block Vol - V05" = 0.6 V or more
Battery Block Vol-V08 (VB8) Battery Block Vol-V07 (VB7) "Battery Block Vol - V07" - "Battery Block Vol - V08" = 0.6 V or more

A309350E10
0.969,2.031 1.427,2.229 0.458,0.198 10 false VB2 2.229,2.031 2.688,2.229 0.458,0.198 10 false VB3 2.583,2.031 3.042,2.229 0.458,0.198 10 false VB4 3.854,2.031 4.313,2.229 0.458,0.198 10 false VB5 4.198,2.031 4.656,2.229 0.458,0.198 10 false VB6 5.479,2.031 5.938,2.229 0.458,0.198 10 false VB7 5.833,2.031 6.292,2.229 0.458,0.198 10 false VB8 0.625,2.031 1.083,2.229 0.458,0.198 10 false VB1 0.635,4.427 1.094,4.625 0.458,0.198 10 false VB1 0.99,4.427 1.448,4.625 0.458,0.198 10 false VB2 2.25,4.427 2.708,4.625 0.458,0.198 10 false VB3 2.604,4.427 3.063,4.625 0.458,0.198 10 false VB4 3.865,4.427 4.323,4.625 0.458,0.198 10 false VB5 4.219,4.427 4.677,4.625 0.458,0.198 10 false VB6 5.479,4.427 5.938,4.625 0.458,0.198 10 false VB7 5.844,4.427 6.302,4.625 0.458,0.198 10 false VB8 1.594,3.177 1.958,3.792 0.365,0.615 10 false 0.6 V or more 3.188,3.177 3.563,3.781 0.375,0.604 10 false 0.6 V or more 4.802,3.188 5.177,3.833 0.375,0.646 10 false 0.6 V or more 6.427,3.177 6.802,3.792 0.375,0.615 10 false 0.6 V or more 6.427,0.802 6.813,1.375 0.385,0.573 10 false 0.6 V or more 4.823,0.813 5.219,1.448 0.396,0.635 10 false 0.6 V or more 3.24,0.802 3.615,1.385 0.375,0.583 10 false 0.6 V or more 1.594,0.813 1.969,1.458 0.375,0.646 10 false 0.6 V or more 0.083,0.073 4.792,0.344 4.708,0.271 10 false Example: When difference in voltage of all 4 pairs of blocks is 0.6 V or more 0.542,0.375 2.896,0.573 2.354,0.198 10 false All conditions in table 1 are met. 4.938,0.115 7.052,0.333 2.115,0.219 10 false A: Circuit A Battery Block Voltage 4.948,0.438 7.052,0.698 2.104,0.26 10 false B: Circuit B Battery Block Voltage 0.563,2.781 2.771,3.042 2.208,0.26 10 false All conditions in table 2 are met. 0.74,2.198 1.198,2.396 0.458,0.198 10 false A 2.635,2.198 3.094,2.396 0.458,0.198 10 false A 3.979,2.188 4.438,2.385 0.458,0.198 10 false A 5.875,2.198 6.333,2.396 0.458,0.198 10 false A 0.74,4.583 1.198,4.781 0.458,0.198 10 false A 2.646,4.583 3.104,4.781 0.458,0.198 10 false A 3.979,4.583 4.438,4.781 0.458,0.198 10 false A 5.885,4.583 6.344,4.781 0.458,0.198 10 false A 1.01,2.198 1.469,2.396 0.458,0.198 10 false B 2.354,2.198 2.813,2.396 0.458,0.198 10 false B 4.26,2.198 4.719,2.396 0.458,0.198 10 false B 5.594,2.208 6.052,2.406 0.458,0.198 10 false B 5.604,4.583 6.01,4.792 0.406,0.208 10 false B 4.271,4.583 4.688,4.792 0.417,0.208 10 false B 2.365,4.583 2.781,4.792 0.417,0.208 10 false B 1.031,4.583 1.448,4.792 0.417,0.208 10 false B 0.313,3.094 0.729,3.302 0.417,0.208 10 false V 0.313,0.698 0.729,0.906 0.417,0.208 10 false V

Result:
Result Proceed to
All conditions in table 1 are met. A
All conditions in table 2 are met.
Other than above. B


g.

Turn the power switch off.



A

B

4.CHECK BATTERY SMART UNIT
4.CHECK BATTERY SMART UNIT
NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.



b.

Measure the resistance according to the value(s) in the table below.

HINT:

It is only necessary measure the resistance of the battery smart unit at the terminals which relate to the lower voltage battery block of pairs of battery blocks for which the difference in voltage in the freeze frame data was 0.6 V or more.


A417508C03
1.156,2.229 1.594,2.521 0.438,0.292 1.885,2.229 2.323,2.521 0.438,0.292 2.563,2.24 3,2.531 0.438,0.292 3.271,2.25 3.708,2.542 0.438,0.292 0.344,0.115 1,0.729 0.656,0.615 10 false *a 1.271,2.271 1.854,2.615 0.583,0.344 10 false z31 2.01,2.271 2.594,2.615 0.583,0.344 10 false z30 2.667,2.281 3.25,2.625 0.583,0.344 10 false z33 3.365,2.302 3.948,2.646 0.583,0.344 10 false z32
*a Component without harness connected
(Battery Smart Unit)
- -


Standard Resistance (When Value of Battery Block Vol-V01 (VB1) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z32-13 (GA0) (-) - z32-9 (VA1) (+) Always 50 kΩ or higher
z32-9 (VA1) (-) - z32-5 (VA2) (+) Always 50 kΩ or higher
z32-5 (VA2) (-) - z32-1 (VA3) (+) Always 50 kΩ or higher
z32-1 (VA3) (-) - z32-14 (VA4) (+) Always 50 kΩ or higher
z32-14 (VA4) (-) - z32-10 (VA5) (+) Always 50 kΩ or higher
z32-10 (VA5) (-) - z32-6 (VA6) (+) Always 50 kΩ or higher
z32-6 (VA6) (-) - z32-2 (VA7) (+) Always 50 kΩ or higher
z32-13 (GA0) (-) -z32-2 (VA7) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V02 (VB2) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z32-2 (VA7) (-) - z32-15 (VA8) (+) Always 50 kΩ or higher
z32-15 (VA8) (-) - z32-11 (VA9) (+) Always 50 kΩ or higher
z32-11 (VA9) (-) - z32-7 (VA10) (+) Always 50 kΩ or higher
z32-7 (VA10) (-) - z32-16 (VA11) (+) Always 50 kΩ or higher
z32-16 (VA11) (-) - z32-12 (VA12) (+) Always 50 kΩ or higher
z32-12 (VA12) (-) - z32-8 (VA13) (+) Always 50 kΩ or higher
z32-8 (VA13) (-) - z32-4 (VA14) (+) Always 50 kΩ or higher
z32-2 (VA7) (-) - z32-4 (VA14) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V03 (VB3) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z33-11 (GA1) (-) - z33-6 (VA15) (+) Always 50 kΩ or higher
z33-6 (VA15) (-) - z33-1 (VA16) (+) Always 50 kΩ or higher
z33-1 (VA16) (-) - z33-12 (VA17) (+) Always 50 kΩ or higher
z33-12 (VA17) (-) - z33-7 (VA18) (+) Always 50 kΩ or higher
z33-7 (VA18) (-) - z33-2 (VA19) (+) Always 50 kΩ or higher
z33-2 (VA19) (-) - z33-13 (VA20) (+) Always 50 kΩ or higher
z33-13 (VA20) (-) - z33-8 (VA21) (+) Always 50 kΩ or higher
z33-11 (GA1) (-) - z33-8 (VA21) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V04 (VB4) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z33-8 (VA21) (-) - z33-3 (VA22) (+) Always 50 kΩ or higher
z33-3 (VA22) (-) - z33-14 (VA23) (+) Always 50 kΩ or higher
z33-14 (VA23) (-) - z33-9 (VA24) (+) Always 50 kΩ or higher
z33-9 (VA24) (-) - z33-4 (VA25) (+) Always 50 kΩ or higher
z33-4 (VA25) (-) - z33-15 (VA26) (+) Always 50 kΩ or higher
z33-15 (VA26) (-) - z33-10 (VA27) (+) Always 50 kΩ or higher
z33-10 (VA27) (-) - z33-5 (VA28) (+) Always 50 kΩ or higher
z33-8 (VA21) (-) - z33-5 (VA28) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V05 (VB5) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z30-11 (GA2) (-) - z30-6 (VA29) (+) Always 50 kΩ or higher
z30-6 (VA29) (-) - z30-1 (VA30) (+) Always 50 kΩ or higher
z30-1 (VA30) (-) - z30-12 (VA31) (+) Always 50 kΩ or higher
z30-12 (VA31) (-) - z30-7 (VA32) (+) Always 50 kΩ or higher
z30-7 (VA32) (-) - z30-2 (VA33) (+) Always 50 kΩ or higher
z30-2 (VA33) (-) - z30-13 (VA34) (+) Always 50 kΩ or higher
z30-13 (VA34) (-) - z30-8 (VA35) (+) Always 50 kΩ or higher
z30-11 (GA2) (-) - z30-8 (VA35) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V06 (VB6) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z30-8 (VA35) (-) - z30-3 (VA36) (+) Always 50 kΩ or higher
z30-3 (VA36) (-) - z30-14 (VA37) (+) Always 50 kΩ or higher
z30-14 (VA37) (-) - z30-9 (VA38) (+) Always 50 kΩ or higher
z30-9 (VA38) (-) - z30-4 (VA39) (+) Always 50 kΩ or higher
z30-4 (VA39) (-) - z30-15 (VA40) (+) Always 50 kΩ or higher
z30-15 (VA40) (-) - z30-10 (VA41) (+) Always 50 kΩ or higher
z30-10 (VA41) (-) - z30-5 (VA42) (+) Always 50 kΩ or higher
z30-8 (VA35) (-) - z30-5 (VA42) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V07 (VB7) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z31-13 (GA3) (-) - z31-9 (VA43) (+) Always 50 kΩ or higher
z31-9 (VA43) (-) - z31-5 (VA44) (+) Always 50 kΩ or higher
z31-5 (VA44) (-) - z31-1 (VA45) (+) Always 50 kΩ or higher
z31-1 (VA45) (-) - z31-14 (VA46) (+) Always 50 kΩ or higher
z31-14 (VA46) (-) - z31-10 (VA47) (+) Always 50 kΩ or higher
z31-10 (VA47) (-) - z31-6 (VA48) (+) Always 50 kΩ or higher
z31-6 (VA48) (-) - z31-2 (VA49) (+) Always 50 kΩ or higher
z31-13 (GA3) (-) - z31-2 (VA49) (+) Always 350 kΩ or higher


Standard Resistance (When Value of Battery Block Vol-V08 (VB8) is Low):
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
z31-2 (VA49) (-) - z31-15 (VA50) (+) Always 50 kΩ or higher
z31-15 (VA50) (-) - z31-11 (VA51) (+) Always 50 kΩ or higher
z31-11 (VA51) (-) - z31-7 (VA52) (+) Always 50 kΩ or higher
z31-7 (VA52) (-) - z31-16 (VA53) (+) Always 50 kΩ or higher
z31-16 (VA53) (-) - z31-12 (VA54) (+) Always 50 kΩ or higher
z31-12 (VA54) (-) - z31-8 (VA55) (+) Always 50 kΩ or higher
z31-8 (VA55) (-) - z31-4 (VA56) (+) Always 50 kΩ or higher
z31-2 (VA49) (-) - z31-4 (VA56) (+) Always 350 kΩ or higher


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.




c.

Install the battery smart unit.


Result:
Result Proceed to
All measured values were within specified range. A
Other than above. B



A

B

5.REPLACE BATTERY SMART UNIT