Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER › 2012.03–2014.11
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301576 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  INSTALLATION  


PROCEDURE

Hide 82112 1.INSTALL NO. 2 ENGINE ROOM WIRE

HINT:

Perform this procedure only when replacement of the No. 2 engine room wire is necessary.


a.
A308467

Engage the clamp to Install a the No. 2 engine room wire to the inverter with converter assembly.


b.

Install the nut to the No. 2 engine room wire.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.
A308465

Engage the 2 claws and close the terminal cover.


Hide 2.INSTALL HIGH VOLTAGE FUSE

CAUTION:

Wear insulated gloves.


HINT:

Perform this procedure only when replacement of the high voltage fuse is necessary.


a.

Remove the 9 bolts and inverter cover.

NOTICE:

Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



b.
A248468E02
2.689,2.766 2.879,3.020 0.191,0.253 10 *a 2.689,3.815 2.879,4.068 0.191,0.253 10 *b

Install the high voltage fuse with the 2 bolts.

Text in Illustration
*a CORRECT
*b INCORRECT

Torque:
4.0 N*m (41 kgf*cm, 35 in.*lbf)

NOTICE:
·

Be sure to use a torque wrench to tighten the bolts.

·

The fuse should be installed with its orientation as shown in the illustration.




c.

Temporarily install the inverter cover with the 9 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.


Hide G1143 3.INSTALL MOTOR CABLE BRACKET

a.

Temporarily install the motor cable bracket with the 2 bolts.


b.
A215782E06
2.385,0.823 2.521,1 0.135,0.177 10 true 1 1.781,0.521 1.917,0.698 0.135,0.177 10 true 2

Tighten the 2 bolts in the order shown in the illustration.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide G9200 4.INSTALL INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.
A214665E06
2.333,0.104 2.469,0.271 0.135,0.167 10 true A

Temporarily install the inverter with converter assembly with the 3 bolts.

NOTICE:
·

Since the inverter with converter assembly is very heavy, 2 people are needed to install the inverter with converter assembly. When installing the inverter with converter assembly, do not damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.




b.

Tighten bolt A.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


c.

Tighten the 2 bolts.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


Hide 5.CONNECT WATER HOSE

a.
A214662E05
0.594,1.542 0.76,1.76 0.167,0.219 10 true 1 1.792,1.385 1.938,1.583 0.146,0.198 10 true 2

Connect the water hose to the inverter with converter assembly and lock the hose with the retainer.

NOTICE:
·

Insert the retainer until a click sound is heard.

·

Pull on the hose to confirm that the hose is securely connected.

·

If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.

·

To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipes and disconnected hoses until installation.




b.
A214664E05
2.198,1.938 2.365,2.125 0.167,0.188 10 true 1 1.031,1.677 1.167,1.865 0.135,0.188 10 true 2

Connect the water hose to the inverter with converter assembly and lock the hose with the retainer.

NOTICE:
·

Insert the retainer until a click sound is heard.

·

Pull on the hose to confirm that the hose is securely connected.

·

If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.

·

To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipes and disconnected hoses until installation.




Hide 82112 6.CONNECT NO. 2 ENGINE ROOM WIRE

a.

Disconnect the No. 2 engine room wire from the protector.


b.

Connect the No. 2 engine room wire with the bolt and 2 claws.

Torque:
8.3 N*m (85 kgf*cm, 73 in.*lbf)

NOTICE:

Pass the No. 2 engine room wire under the 2 cooling hoses that pass beside the inverter with converter assembly.



c.

Install the No. 1 relay block cover and 2 clamps.


d.

Install the relay block cover.


Hide G9221 7.REMOVE INVERTER COVER

CAUTION:

Wear insulated gloves.


a.

Remove the 9 bolts and inverter cover.

NOTICE:

Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



Hide 82122 8.CONNECT NO. 2 ENGINE WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A248444E07
0.865,0.573 0.99,0.719 0.125,0.146 10 true A 0.854,0.802 0.979,0.948 0.125,0.146 10 true A 0.625,0.188 0.75,0.333 0.125,0.146 10 true B 0.719,1.01 0.844,1.156 0.125,0.146 10 true B

Temporarily install the No. 2 engine wire (high voltage cables of the air conditioning) and 4 bolts to the inverter with converter assembly by hand.


b.

Fully tighten the 4 bolts.

Torque:
Bolt A : 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Bolt B : 9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



c.

Connect the harness clamp.


Hide G1148 9.CONNECT MOTOR CABLE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A248443E07
2.26,1.083 2.385,1.24 0.125,0.156 10 true A 2.542,1.094 2.667,1.25 0.125,0.156 10 true A 2.802,1.083 2.927,1.24 0.125,0.156 10 true A 2.073,0.188 2.198,0.344 0.125,0.156 10 true B 2.979,0.167 3.104,0.323 0.125,0.156 10 true B

Temporarily install the high voltage cable of the motor cable (MG2) and 5 bolts to the inverter with converter assembly by hand.


b.

Fully tighten the 5 bolts.

Torque:
Bolt A : 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Bolt B : 9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



c.

Connect the harness clamp.


Hide G2148 10.CONNECT GENERATOR CABLE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A248442E06
1.698,1.094 1.833,1.24 0.135,0.146 10 true A 2.042,1.104 2.177,1.25 0.135,0.146 10 true A 2.344,1.083 2.479,1.229 0.135,0.146 10 true A 2.479,0.177 2.615,0.323 0.135,0.146 10 true B 1.531,0.177 1.667,0.323 0.135,0.146 10 true B

Temporarily install the high voltage cable of the generator cable (MG1) and 5 bolts to the inverter with converter assembly by hand.


b.

Fully tighten the 5 bolts.

Torque:
Bolt A : 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Bolt B : 9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



c.
A215780E06
2.344,0.469 2.979,0.594 2.979,0.594 2.406,0.646 false 3.01,0.51 3.208,0.688 0.198,0.177 10 false *a

Install the generator cable and cover.

Text in Illustration
*a Alignment Mark

NOTICE:

Close the cover so that the alignment marks are not visible.



Hide 82164 11.CONNECT FRAME WIRE

CAUTION:

Wear insulated gloves.


NOTICE:
·

Make sure that the interlock is fully engaged.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.



a.
A248445E13
2.438,0.896 2.125,1.031 2.125,1.031 2.042,1.031 true 1.271,0.313 1.698,0.313 false 0.844,1.021 0.969,1.177 0.125,0.156 10 true A 1.24,1.021 1.365,1.177 0.125,0.156 10 false A 1.583,0.479 1.708,0.635 0.125,0.156 10 true B 0.49,0.479 0.615,0.635 0.125,0.156 10 false B 2.417,0.042 2.583,0.208 0.167,0.167 10 false *a 1.875,0.948 2.042,1.115 0.167,0.167 10 false *1 1.708,0.229 1.875,0.406 0.167,0.177 10 false *2

Temporarily install the frame wire (high voltage cables of the hybrid battery) and 4 bolts to the inverter with converter assembly by hand.

Text in Illustration
*1 Interlock
*2 High voltage cables of hybrid battery
*a Front view of frame wire connector


b.

Fully tighten the 4 bolts.

Torque:
Bolt A : 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Bolt B : 9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:
·

Be sure to use a torque wrench to tighten the bolts.

·

Make sure that the interlock are fully engaged.




c.

Connect the harness clamp.


Hide 12. CHECK HIGH VOLTAGE CABLE CONNECTION

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A248462

Check that each connector and terminal is firmly installed.

NOTICE:

Make sure that the bolts are fully tightened.



Hide G9221 13.INSTALL INVERTER COVER

CAUTION:

Wear insulated gloves.


a.
A231540E05
2.615,0.792 2.208,0.792 true 2.031,0.708 2.26,0.917 0.229,0.208 10 false *1

Install the inverter cover with the 9 bolts to the inverter with converter assembly.

Text in Illustration
*1 Interlock

Torque:
11 N*m (112 kgf*cm, 8 ft.*lbf)

NOTICE:
·

Make sure that the interlock is fully engaged.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 82111 14.CONNECT ENGINE ROOM MAIN WIRE

NOTICE:
·

Make sure that the connectors are fully engaged.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.



a.

Install the bolt, clamp and clip, and connect the engine room main wire.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


b.

Install the bolt.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


c.
A214645

Connect the engine wire to the engine room main wire.


d.
A214648

Connect the connector to the inverter with converter assembly and lock the connector with the lock lever.


Hide G9214 15.INSTALL NO. 1 INVERTER BRACKET

a.
A251283E03
0.667,0.271 0.833,0.458 0.167,0.188 10 true 1 2.01,1.156 2.125,1.333 0.115,0.177 10 false 2 0.479,0.927 0.594,1.104 0.115,0.177 10 true 3

Temporarily install the No. 1 inverter bracket with the 3 bolts.


b.

Tighten the 3 bolts in the order shown in the illustration.

Torque:
14 N*m (138 kgf*cm, 10 ft.*lbf)


Hide 51441 19.INSTALL NO. 1 ENGINE UNDER COVER

Hide 53289A 20.INSTALL RADIATOR SUPPORT OPENING COVER