Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL COMPUTER
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301591 MOTOR GENERATOR CONTROL COMPUTER A

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL COMPUTER  REASSEMBLY  


CAUTION / NOTICE / HINT

NOTICE:

Do not cross-thread the bolts when installing them.


PROCEDURE

Hide 1.REMOVE SEAL PACKING (FROM HYBRID CONVERTER KIT CONTACT SURFACE)

NOTICE:
·

Do not touch the circuit board.

·

Only remove seal packing which is uneven, has peeled off or seeped out from between the contact surfaces.

·

Do not drop any removed seal packing into the hybrid vehicle converter kit.

·

Do not bend the bus-bars.



a.
A315643E02
0.49,0.833 0.344,0.531 0.344,0.531 0.25,0.531 false 2.74,0.406 2.969,0.177 2.969,0.177 3.094,0.177 false 2.969,1.458 3.063,1.75 3.063,1.75 3.167,1.75 false 3.198,1.667 3.385,1.844 0.188,0.177 10 false *1 3.125,0.094 3.313,0.271 0.188,0.177 10 false *1 0.083,0.448 0.271,0.625 0.188,0.177 10 false *1

Put clean pieces of paper into the areas shown in the illustration to prevent any remaining seal packing from entering the hybrid vehicle converter kit.

Text in Illustration
*1 Paper


b.

Using a finger or a scraper with its tip wrapped with protective tape, remove any remaining seal packing which is uneven, has peeled off or seeped out from around the contact surface shown in the illustration and inside the bolt holes.

A315644E02
2.302,1.552 2.51,2.063 2.51,2.063 2.677,2.063 false 1.844,1.833 2.052,2.333 2.052,2.333 2.219,2.333 false 5.365,0.854 5.594,0.573 5.594,0.573 5.76,0.573 false 5.25,2.115 5.479,1.823 5.479,1.823 5.656,1.823 false 5.073,0.771 5.49,0.229 5.49,0.229 5.656,0.229 false 4.677,0.385 4.875,0.156 4.875,0.156 5.042,0.156 false 2.25,2.26 2.521,2.438 0.271,0.177 10 false *2 2.708,1.99 2.979,2.167 0.271,0.177 10 false *1 5.792,0.479 6.063,0.656 0.271,0.177 10 false *3 5.688,1.75 5.958,1.927 0.271,0.177 10 false *3 5.698,0.156 5.969,0.333 0.271,0.177 10 false *2 5.083,0.083 5.354,0.26 0.271,0.177 10 false *2 4.073,0.104 4.344,0.281 0.271,0.177 10 false *a

Text in Illustration
*1 Paper *2 Seeped Out or Uneven Seal Packing
*3 Light Coat of Seal Packing Remaining on Contact Surface - -
*a Minimum Requirement for Removal of Seal Packing - -

NOTICE:

Do not allow any moisture to come into contact with the circuit board.



Hide 2.REMOVE SEAL PACKING (FROM INVERTER CASE WITH CONDENSER CONTACT SURFACE)

NOTICE:
·

Only remove seal packing which is uneven, has peeled off or seeped out from between the contact surfaces.

·

Do not drop any removed seal packing into the inverter case with condenser.

·

Do not bend the bus-bars.



a.

Set the inverter case with condenser on its side as shown in the illustration.

NOTICE:

To prevent the inverter case with condenser from falling over, hold it by hand or place an object behind it.



b.

Using a finger or a scraper with its tip wrapped with protective tape, remove any remaining seal packing which is uneven, has peeled off or seeped out from around the contact surface shown in the illustration and inside the bolt holes.

A347781E05
5.063,0.75 5.469,0.198 false 5.469,0.198 5.594,0.198 false 5.375,0.844 5.583,0.573 false 5.583,0.573 5.677,0.573 false 5.313,2.156 5.51,1.885 false 5.51,1.885 5.646,1.885 false 1.552,1.021 1.635,0.313 1.635,0.313 1.813,0.313 false 2.052,2.115 2.26,2.469 2.26,2.469 2.417,2.469 false 4.719,0.427 4.938,0.208 4.938,0.208 5.094,0.208 false 1.844,0.229 2.135,0.427 0.292,0.198 10 false *1 2.458,2.375 2.75,2.573 0.292,0.198 10 false *1 5.125,0.115 5.417,0.313 0.292,0.198 10 false *1 5.635,0.135 5.927,0.333 0.292,0.198 10 false *1 5.708,0.49 6,0.688 0.292,0.198 10 false *2 5.677,1.823 5.969,2.021 0.292,0.198 10 false *2 4.042,0.094 4.333,0.292 0.292,0.198 10 false *a

Text in Illustration
*1 Seeped Out or Uneven Seal Packing *2 Light Coat of Seal Packing Remaining on Contact Surface
*a Minimum Requirement for Removal of Seal Packing - -


Hide 3.REMOVE ADHESIVE (FROM NO. 1 AND NO. 2 INVERTER DRAIN PLUGS SEALING SURFACE)

a.
A347773E01
2.993,1.703 3.228,1.886 0.235,0.183 10 *1 0.713,1.254 0.948,1.437 0.235,0.183 10 *1 0.363,1.677 0.598,1.860 0.235,0.183 10 *1 1.011,1.52 0.854,1.779 false 0.867,1.773 0.544,1.773 false 2.471,1.693 2.624,1.796 false 2.624,1.796 2.955,1.796 false

Remove the protective tape from the installation holes of the No. 1 and No. 2 inverter drain plugs.

Text in Illustration
*1 Protective Tape


b.
A314638E01
0.199,0.615 0.471,0.796 0.272,0.181 10 *1 2.672,0.192 2.944,0.373 0.272,0.181 10 *1 2.329,0.613 2.514,0.284 2.514,0.284 2.635,0.284 false 0.713,1.096 0.526,0.703 0.526,0.703 0.405,0.703 false

Apply protective tape to the No. 1 and No. 2 inverter drain plugs installation holes from the inside.

Text in Illustration
*1 Protective Tape

NOTICE:

Do not bend the bus-bars when applying protective tape.



c.
A314637E01
2.552,0.077 2.825,0.258 0.272,0.181 10 *1 1.836,0.894 2.365,0.169 2.365,0.169 2.519,0.169 false

Using a scraper with its tip wrapped with protective tape, remove any remaining adhesive from the sealing surface of 2 inverter drain plugs.

Text in Illustration
*1 Sealing Surface

NOTICE:

Do not damage the sealing surfaces.



d.

Remove any adhesive shavings particles using tape or equivalent.


e.

Remove the protective tape from the inside of the inverter case with condenser.


f.
A347773E01
2.993,1.703 3.228,1.886 0.235,0.183 10 *1 0.713,1.254 0.948,1.437 0.235,0.183 10 *1 0.363,1.677 0.598,1.860 0.235,0.183 10 *1 1.011,1.52 0.854,1.779 false 0.867,1.773 0.544,1.773 false 2.471,1.693 2.624,1.796 false 2.624,1.796 2.955,1.796 false

Apply protective tape to the installation holes of the No. 1 and No. 2 inverter drain plugs as shown in the illustration.

Text in Illustration
*1 Protective Tape


Hide 4.REMOVE RESIDUE (FROM INVERTER SIGNAL CONNECTOR COVER SEALING SURFACE)

a.
A315685E01
2.779,0.097 3.052,0.279 0.272,0.181 10 *1 2.15,0.713 2.594,0.192 2.594,0.192 2.749,0.192 false

Apply protective tape to the area shown in the illustration to prevent removed residue from entering the inverter case with condenser.

Text in Illustration
*1 Protective Tape


b.
A347783

Using 600-grit sandpaper, remove the residue from each grommet sealing surface until it feels smooth.

NOTICE:
·

Use 600-grit or higher sandpaper.

·

Do not allow removed residue to enter the inverter case with condenser or hybrid vehicle converter kit.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.




c.

Remove any adhesive particles using tape or equivalent.


d.

Remove the protective tape.


e.

Thoroughly wash hands after performing this step.

HINT:

This step is not necessary if performing the "Remove Residue (from Grommet Sealing Surface)" procedure next.



Hide 5.REMOVE RESIDUE (FROM GROMMET SEALING SURFACE)

HINT:

Perform the following procedure only when there is residue on the grommet sealing surfaces:


a.

Apply protective tape to the areas shown in the illustration to prevent removed residue from entering the inverter case with condenser and hybrid vehicle converter kit.

A317101E02
1.458,0.333 1.583,0.333 1.583,0.333 1.708,0.5 false 0.271,1.365 0.469,1.542 0.198,0.177 10 false *1 1.271,0.26 1.469,0.438 0.198,0.177 10 false *3 3.844,1.344 4.042,1.521 0.198,0.177 10 false *2

Text in Illustration
*1 Inverter Case with Condenser *2 Hybrid Vehicle Converter Kit
*3 Protective Tape - -


b.

Using 600-grit sandpaper, remove the residue from each grommet sealing surface until it feels smooth.

A315684E04
0.594,1.167 0.76,1.167 0.76,1.167 1.333,1 true 0.594,0.51 0.781,0.51 0.781,0.51 1.292,0.802 true 0.438,1.073 0.75,1.281 0.313,0.208 10 false *a 0.438,0.406 0.75,0.615 0.313,0.208 10 false *a

Text in Illustration
*a Residue - -

NOTICE:
·

Use 600-grit or higher sandpaper.

·

Do not allow removed residue to enter the inverter case with condenser or hybrid vehicle converter kit




c.

Remove any adhesive shavings particles using tape or equivalent.


d.

Remove the protective tape.


e.

Thoroughly wash hands after performing this step.


Hide 6.CLEAN INVERTER SIGNAL CONNECTOR COVER

a.
A314639E01
2.201,0.008 2.387,0.158 0.186,0.150 10 *1

Remove the gasket from the inverter signal connector cover. Wash the gasket and inverter signal connector cover with water and dry them completely.

Text in Illustration
*1 Gasket

NOTICE:

Do not damage the gasket.



b.

Thoroughly wash hands after performing this step.


Hide 7.INSTALL MG CONTROL COMPUTER WITH BRACKET SUB-ASSEMBLY

NOTICE:
·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the circuit board.



a.

Align the holes of the MG control computer with bracket sub-assembly with the guide pins and temporarily install the power module intelligent transistor kit to the hybrid converter kit.

A317081E03
2.219,1.531 2.417,1.531 false 1.844,3.635 3.094,4.208 3.094,4.208 3.302,4.208 false 2.438,1.448 2.708,1.625 0.271,0.177 10 false *1 3.333,4.104 3.719,4.281 0.385,0.177 10 false *1

Text in Illustration
*1 Guide Pins *2 -

NOTICE:

Make sure to align the guide pins correctly.



b.

Install the MG control computer with bracket sub-assembly with the 4 bolts.


c.
A314606E05
2.406,2.969 2.542,3.146 0.135,0.177 10 false 1 2.5,0.552 2.635,0.729 0.135,0.177 10 true 2 0.708,0.604 0.844,0.781 0.135,0.177 10 false 3 0.313,3.021 0.448,3.198 0.135,0.177 10 false 4

Temporarily tighten the 4 bolts evenly in several steps in the order shown in the illustration, then fully tighten them.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)


d.

Engage the 2 wire harnesses to the 4 clamps.

A315647


e.

Connect the 2 connectors to the MG control computer with bracket sub-assembly.


f.
A317080

Disengage the lock claws of the white resin connector and connect the flat cable to the power module intelligent transistor kit.


g.

Check that the flat cable is connected securely.

NOTICE:
A317060

If the flat cable is not fully connected, connect it securely.



h.
A315646E01
2.714,0.025 2.986,0.206 0.272,0.181 10 *1 1.933,0.538 2.384,0.12 2.384,0.12 2.691,0.12 false

If the gasket of the inverter signal connector is protruding, fully push it in.

Text in Illustration
*1 Gasket

HINT:
A317062E06
1.823,0.635 1.969,0.219 1.969,0.219 2.094,0.219 false 2.854,1.094 3.083,1.094 false 0.573,1.094 0.802,1.094 false 1.104,0.646 1.271,0.292 1.271,0.292 1.406,0.292 false 1.833,1.552 2,1.99 2,1.99 2.104,1.99 false 2.115,1.906 2.385,2.083 0.271,0.177 10 false *2 2.125,0.135 2.396,0.313 0.271,0.177 10 false *2 3.104,1.01 3.313,1.188 0.208,0.177 10 false *2 0.365,1.01 0.573,1.188 0.208,0.177 10 false *2 1.427,0.208 1.698,0.385 0.271,0.177 10 false *1

If the gasket is misaligned, set it so that each mark is at the center of each side.

Text in Illustration
*1 Gasket
*2 Mark



Hide 8.INSTALL INVERTER TERMINAL WITH SENSOR SUB-ASSEMBLY

NOTICE:
·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the circuit board.

·

For inverter with converter assembly with part number G9200-47160, G9200-47161 or G9200-47162: Make sure to replace the inverter current sensor sub-assembly and inverter wire sub-assembly at the same time when replacing the MG control computer with bracket sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER CURRENT SENSOR>COMPONENTS).



a.

Align the holes of the power module intelligent transistor kit with the guide pins and temporarily install the power module intelligent transistor kit to the hybrid vehicle converter kit.

A317082E01
1.591,2.311 1.863,2.492 0.272,0.181 10 *1 1.115,1.429 1.442,2.381 1.442,2.381 1.573,2.381 false 6.577,2.341 6.849,2.522 0.272,0.181 10 *1 6.057,1.557 6.408,2.424 6.408,2.424 6.547,2.424 false

Text in Illustration
*1 Guide Pins - -

NOTICE:

Make sure to align the guide pins correctly.



b.

Install the inverter terminal with sensor sub-assembly with the 4 bolts.


c.
A314601E01
3.199,1.16 3.340,1.341 0.140,0.181 10 1 0.289,1.048 0.430,1.229 0.140,0.181 10 2 0.546,0.097 0.686,0.278 0.140,0.181 10 3 3.232,0.151 3.373,0.332 0.140,0.181 10 4

Temporarily tighten the 4 bolts evenly in several steps in the order shown in the illustration, then fully tighten them.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)


d.

Connect the 3 connectors to the MG control computer with bracket sub-assembly.

NOTICE:

The location of the connectors varies depending on the part number of the inverter with converter assembly. Confirm the part number before performing work.


i.
A314602

For inverter with converter assembly with part number G9200-47160, G9200-47161 or G9200-47162:

HINT:

If the MG control computer with bracket sub-assembly has been replaced, it is necessary to refer to the illustration for inverter with converter assemblies with part numbers other than those listed above to confirm the position of the connectors, even if an inverter with converter assembly with a part number listed above has been installed.



ii.
A351835

For inverter with converter assembly with part number other than G9200-47160, G9200-47161 or G9200-47162:



e.

Check that the 5 connectors and flat cable are connected securely as shown in the illustration.

i.
A408788

For inverter with converter assembly with part number G9200-47160, G9200-47161 or G9200-47162:


ii.
A408791

For inverter with converter assembly with part number other than G9200-47160, G9200-47161 or G9200-47162:



f.

If a pen sheet is provided, check the installation condition of the pen sheet.

NOTICE:
·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the circuit board.



i.

While ensuring that the pen sheet does not interfere with components of the circuit board, insert the pen sheet between the inverter terminal with sensor sub-assembly and MG control computer with bracket sub-assembly.

A315648E01
3.033,2.215 3.306,2.396 0.272,0.181 10 *1 2.663,1.841 2.856,2.29 2.856,2.29 3.007,2.29 false 6.021,2.196 6.294,2.377 0.272,0.181 10 *1 5.585,1.816 5.818,2.265 5.818,2.265 6,2.265 false

Text in Illustration
*1 PEN Sheet - -


ii.
A315649E04
2.708,2.469 2.938,3.042 2.938,3.042 3.052,3.042 false 2.885,0.99 3.031,1.677 3.031,1.677 3.188,1.677 false 2.073,0.656 1.406,0.396 1.406,0.396 1.219,0.396 false 1.677,2.135 1.813,1.792 1.813,1.792 1.99,1.792 false 3.073,2.969 3.271,3.146 0.198,0.177 10 false *1 3.208,1.615 3.365,1.792 0.156,0.177 10 false *1 1.031,0.302 1.229,0.479 0.198,0.177 10 false *2 2.01,1.719 2.208,1.896 0.198,0.177 10 false *3

Set the pen sheet so that the pin of the motor generator control computer sub-assembly is aligned with the guide hole as shown in the illustration.

Text in Illustration
*1 Guide Pin
*2 Double-sided Tape
*3 PEN Sheet


iii.

Attach the double-sided tape of the pen sheet to the connector shown in the illustration.



g.
A315667E01
1.465,0.129 1.605,0.311 0.140,0.181 10 A 0.947,1.325 1.301,0.23 1.301,0.23 1.429,0.23 false

Install the 6 bolts to the bus-bars.

Torque:
6.0 N*m (61 kgf*cm, 53 in.*lbf)

NOTICE:

Do not touch the bus-bars.



h.
A315664E01
1.666,0.031 1.938,0.212 0.272,0.181 10 *1 2.022,0.26 1.967,0.118 1.967,0.118 1.865,0.118 false

If the No. 2 engine room wire is installed, install the bolt (A) using SST as shown in the illustration.

SST
09961-00950  

Torque:
without SST : 6.0 N*m (61 kgf*cm, 53 in.*lbf)
with SST : 3.3 N*m (34 kgf*cm, 29 in.*lbf)

Text in Illustration
*1 SST

NOTICE:

This torque value is effective when SST is parallel to the torque wrench.


HINT:
·
A315672E06
0.948,1.177 1.073,1.615 1.073,1.615 1.208,1.615 false 1.24,1.531 1.51,1.708 0.271,0.177 10 false *1 0.979,0.313 1.25,0.49 0.271,0.177 10 false *a 2.188,0.313 2.458,0.49 0.271,0.177 10 false *b

The "with SST" torque value is effective when using SST with a fulcrum length of 150 mm (5.91 in.).

Text in Illustration
*1 SST
*a Length of SST 150 mm (5.91 in.)
*b Length of Torque Wrench 185 mm (7.28 in.)

·

The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 185 mm (7.28 in.)

·

If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values. (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION)

·

Loosen the nut of the No. 2 engine room wire to secure enough space to perform work.




Hide 9.INSTALL INVERTER CASE WITH CONDENSER

NOTICE:
·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the circuit board.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the hybrid vehicle converter kit and inverter case with condenser.



a.

Apply seal packing (diameter: 2.0 to 3.0 mm (0.0787 to 0.118 in.)) in a continuous line to the locations shown in the illustration.

A319330E05
0.656,0.938 0.781,0.938 0.781,0.938 0.875,1.469 false 1.208,2.469 1.094,2.469 1.094,2.469 1.01,2.198 false 6.448,0.688 6.323,0.688 6.323,0.688 6.271,0.854 false 5.635,0.99 5.635,1.177 false 6.667,0.979 6.667,1.208 false 4.896,1.563 4.781,1.563 4.781,1.563 4.615,1.177 false 2.177,2.438 2.063,2.438 2.063,2.438 2.365,1.927 false 1.24,2.396 1.406,2.563 0.167,0.167 10 false *1 0.49,0.875 0.656,1.042 0.167,0.167 10 false *2 2.271,1.573 2.438,1.74 0.167,0.167 10 false *2 2.292,0.708 2.458,0.875 0.167,0.167 10 false *2 2.448,2.26 2.615,2.427 0.167,0.167 10 false *2 4.063,2.25 4.229,2.417 0.167,0.167 10 false *2 4.49,0.594 4.656,0.76 0.167,0.167 10 false *2 5.438,0.667 5.604,0.833 0.167,0.167 10 false *c 6.479,0.635 6.646,0.802 0.167,0.167 10 false *3 6.583,1.229 6.75,1.396 0.167,0.167 10 false *1 5.563,1.208 5.729,1.375 0.167,0.167 10 false *1 6.125,1.656 6.292,1.823 0.167,0.167 10 false *a 5.583,2.177 5.75,2.344 0.167,0.167 10 false *b 4.927,1.49 5.094,1.656 0.167,0.167 10 false *3 2.208,2.365 2.375,2.531 0.167,0.167 10 false *3

Text in Illustration
*1 Seal Packing *2 Bolt Hole
*3 Coolant Pipes - -
*a 2.0 to 3.0 mm (0.0787 to 0.118 in.) *b 2.0 to 3.0 mm (0.0787 to 0.118 in.)
*c Around Coolant Pipe - -

Seal Packing:

Toyota Genuine Seal Packing 1282B, Three Bond 1282B or equivalent


NOTICE:
·

Install the inverter case with condenser within 3 minutes of applying seal packing.

·

Tighten the bolts within 15 minutes of applying seal packing.

·

Keep the coolant pipes free from seal packing.




b.

Install the inverter case with condenser.

i.
A347772E04
1.948,0.323 2.135,0.125 2.135,0.125 2.302,0.125 false 2.573,1.625 2.948,1.719 2.948,1.719 3.115,1.719 false 1.156,1.438 0.844,1.719 0.844,1.719 0.635,1.719 false 2.354,0.052 2.583,0.26 0.229,0.208 10 false *1 3.167,1.635 3.354,1.844 0.188,0.208 10 false *1 0.427,1.625 0.656,1.833 0.229,0.208 10 false *1

Peel back the protective tape to the extent that the following steps can be performed.

Text in Illustration
*1 Protective Tape

NOTICE:

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.



ii.

Temporarily install the inverter case with condenser to the hybrid vehicle converter kit so that the bus-bar (A) does not contact the protrusion of the inverter terminal sub-assembly w/ sensor (B).

A317057E03
1.552,2.167 2.094,2.448 2.094,2.448 2.26,2.448 false 5.792,2.052 6.479,2.323 6.479,2.323 6.688,2.323 false 5.688,0.635 6.021,0.25 6.021,0.25 6.198,0.25 false 5.354,0.802 4.76,1.281 4.76,1.281 4.76,1.469 false 2.292,2.375 2.563,2.552 0.271,0.177 10 false *1 6.708,2.24 6.979,2.417 0.271,0.177 10 false *1 6.24,0.188 6.51,0.365 0.271,0.177 10 false A 4.729,1.5 4.969,1.677 0.24,0.177 10 false B

Text in Illustration
*1 Guide Pins - -

NOTICE:
·

Make sure to align the guide pins correctly.

·
A314613

Check that the bus-bars of the hybrid converter kit overlap the bus-bars of the inverter case with condenser.

·
A317087E04
1.719,1.302 1.885,1.698 1.885,1.698 2.094,1.698 false 2.135,1.604 2.406,1.781 0.271,0.177 10 false *1

Make sure that the bus-bar (A) is not resting on the resin part of the inverter terminal with sensor sub-assembly as shown in the illustration.



Text in Illustration
*1 Bus-bar (A)



c.
A314596

Temporarily install the inverter case with condenser with the 11 bolts.

Torque:
4.0 N*m (41 kgf*cm, 35 in.*lbf)


d.

Fully tighten the 11 bolts.

Torque:
9.2 N*m (94 kgf*cm, 81 in.*lbf)


e.
A314599

Install the 5 bolts to the bus-bars.

Torque:
6.0 N*m (61 kgf*cm, 53 in.*lbf)

NOTICE:

Do not touch the bus-bars.



f.
A319356

Install the nut to the No. 2 engine room wire.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:

Check that the nut is not cross-threaded and the terminal is not loose.



g.
A317066

Engage the 2 claws and close the terminal cover.


Hide 10.INSTALL INVERTER UNION GROMMET

a.
A315660E01
1.895,0.197 2.167,0.379 0.272,0.181 10 *1 1.44,0.965 1.62,0.307 1.62,0.307 1.849,0.307 false

Apply a light coat of seal packing to 2 new inverter union grommets.

Text in Illustration
*1 Seal Packing

Seal Packing:

Toyota Genuine Seal Packing 1282B, Three Bond 1282B or equivalent


NOTICE:
·

Install the inverter union grommets within 60 minutes of installing the inverter case with condenser.

·

Apply a light coat of seal packing to the entire surface of the area shown in the illustration. If seal packing is applied excessively, it may seep out, however, sealing quality will not be affected.

·

Install the inverter union grommets within 3 minutes of applying seal packing.




b.
A317083E04
1.99,0.865 2.229,0.198 2.229,0.198 2.365,0.198 false 1.719,1.354 1.521,1.552 1.521,1.552 1.354,1.552 false 1.573,2.969 1.375,3.156 1.375,3.156 1.208,3.156 false 2.177,1.167 2.292,1.375 2.292,1.375 2.417,1.375 false 2.146,2.479 2.375,1.948 2.375,1.948 2.51,1.948 false 1.979,2.802 2.292,3.208 2.292,3.208 2.438,3.208 false 1.146,1.458 1.417,1.635 0.271,0.177 10 false *1 2.385,0.104 2.656,0.281 0.271,0.177 10 false *a 2.448,1.281 2.719,1.458 0.271,0.177 10 false *2 2.448,3.115 2.719,3.292 0.271,0.177 10 false *a 2.521,1.875 2.792,2.052 0.271,0.177 10 false *2 0.99,3.073 1.26,3.25 0.271,0.177 10 false *1

Push in the inverter union grommet until it passes over the flange of the coolant pipe.

Text in Illustration
*1 Coolant Pipe
*2 Inverter Union Grommet
*a Flange

NOTICE:

Do not damage the coolant pipes.



c.
A317058E01
2.541,0.633 2.814,0.814 0.272,0.181 10 *1 2.135,1.029 2.348,0.731 2.348,0.731 2.508,0.731 false

Using a 30 mm socket, install the inverter union grommet.

Text in Illustration
*1 30 mm Socket

HINT:
A314623E05
2.146,2.063 2.458,2.219 0.313,0.156 10 false *a

Make sure that the clearance between the inverter union grommet and inverter case with condenser is 2.0 mm (0.0787 in.) or less.

Text in Illustration
*a 2.0 mm (0.0787 in.) or less



d.

Perform the same procedure to install the other inverter union grommet.


Hide 11.INSTALL NO. 1 AND NO. 2 INVERTER DRAIN PLUGS

NOTICE:

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.


a.
A348655E06
2.323,2.979 2.156,2.979 2.156,2.979 2.031,2.677 false 2.281,1.625 2.115,1.625 2.115,1.625 1.99,1.323 false 2.333,1.531 2.563,1.719 0.229,0.188 10 false *1 2.365,2.896 2.594,3.083 0.229,0.188 10 false *1

Make sure that the sealing surfaces of the No. 1 and No. 2 inverter drain plugs are covered with aluminum tape.

Text in Illustration
*1 Aluminum Tape

NOTICE:

If the sealing surfaces of the No. 1 and No. 2 inverter drain plugs are not covered with aluminum tape, do not use them as they cannot be securely installed with only seal packing.



b.
A350409E06
1.302,3.063 1.156,3.063 1.156,3.063 1,2.802 false 1.115,1.438 0.969,1.438 0.969,1.438 0.813,1.177 false 1.146,1.344 1.5,1.615 0.354,0.271 10 false *1 1.344,2.969 1.698,3.24 0.354,0.271 10 false *1

Remove the release film from the No. 1 and No. 2 inverter drain plugs.

Text in Illustration
*1 Release Film


c.
A315650E06
1.927,0.417 2.094,0.146 2.094,0.146 2.25,0.146 false 2.094,1.948 2.229,1.698 2.229,1.698 2.406,1.698 false 2.26,0.906 2.396,1.104 2.396,1.104 2.531,1.104 false 0.875,1.719 0.771,1.49 0.771,1.49 0.615,1.49 false 2.281,0.083 2.552,0.26 0.271,0.177 10 false *1 0.417,1.417 0.688,1.594 0.271,0.177 10 false *2 2.542,1.021 2.813,1.198 0.271,0.177 10 false *3 2.417,1.604 2.688,1.781 0.271,0.177 10 false *3 2.844,2.188 3.115,2.365 0.271,0.177 10 false *a 2.469,2.802 2.74,2.979 0.271,0.177 10 false *b

Apply seal packing (diameter: 3.0 mm (0.118 in.)) to new No. 1 and No. 2 inverter drain plugs.

Text in Illustration
*1 No. 1 Inverter Drain Plug
*2 No. 2 Inverter Drain Plug
*3 Seal Packing
*a Approximately 3.0 mm (0.118 in.)
*b Approximately 3.0 mm (0.118 in.)

Seal Packing:

Toyota Genuine Seal Packing 1282B, Three Bond 1282B or equivalent


NOTICE:
·

Be sure to use the specified type of seal packing.

·

Install the No. 1 and No. 2 inverter drain plugs within 3 minutes of applying seal packing.




d.
A314636E02
1.167,1.396 1.031,1.865 1.031,1.865 0.875,1.865 false 2.271,1.552 2.396,1.917 2.396,1.917 2.521,1.917 false 0.688,1.781 0.958,1.958 0.271,0.177 10 false *1 2.542,1.833 2.813,2.01 0.271,0.177 10 false *2

Install the No. 1 and No. 2 inverter drain plugs to the inverter with converter assembly.

Text in Illustration
*1 No. 1 Inverter Drain Plug
*2 No. 2 Inverter Drain Plug


Hide 12.INSTALL INVERTER SIGNAL CONNECTOR COVER

a.
A314639E03
1.247,0.089 1.520,0.271 0.272,0.181 10 A 1.795,0.502 1.577,0.178 false 1.577,0.178 1.434,0.178 false 2.181,0.003 2.454,0.185 0.272,0.181 10 *1

Install the gasket to the inverter signal connector cover.

HINT:

Make sure that the protrusion (A) of the gasket is securely inserted into the groove of the inverter signal connector cover.


Text in Illustration
*1 Gasket


b.

Clean the installation surface.


c.
A314598E02
0.287,0.13 0.560,0.312 0.272,0.181 10 *1 0.93,0.699 0.698,0.215 0.698,0.215 0.503,0.215 false

Install the inverter signal connector cover with the 4 bolts.

Torque:
6.0 N*m (61 kgf*cm, 53 in.*lbf)

Text in Illustration
*1 Inverter Signal Connector Cover


Hide 13.INSTALL INVERTER TERMINAL COVER

a.
A314616E01
2.929,0.237 3.201,0.418 0.272,0.181 10 *1 0.084,0.324 0.270,0.505 0.186,0.181 10 *1 2.572,0.818 2.809,0.341 2.809,0.341 2.933,0.341 false 1.057,0.545 0.293,0.412 0.293,0.412 0.821,0.768 false

Remove the protective tape.

Text in Illustration
*1 Protective Tape


b.
A209686

Temporarily install the inverter terminal cover with the 9 bolts to prevent any foreign objects or water from entering the inverter with converter assembly.


Hide G9200 14.INSTALL INVERTER WITH CONVERTER ASSEMBLY

Hide 15. CHECK FOR COOLANT LEAK (for Inverter)

a.

Remove the reserve tank cap.

CAUTION:

To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.



b.
A214668

Install the radiator cap tester.


c.

Pump the radiator cap tester to 122 kPa (1.2 kgf/ cm2, 17.7 psi), and then check that the pressure does not drop.

HINT:

If the pressure drops, check the hoses, radiator, water pump, inverter with converter, and hybrid vehicle transaxle assembly for leaks.



d.

Reinstall the reserve tank cap.


Hide 16. OPERATION CHECK

HINT:
·

After the repair, check the operation as follows. Then check for DTCs again.

·

The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.



a.
A174427E02
0.978,0.503 1.569,0.844 0.591,0.341 10 Probe Direction 0.165,1.637 1.163,2.145 0.998,0.508 10 Current Flowing into Auxiliary Battery 0.652,0.955 0.835,0.583 0.835,0.583 0.95,0.583 false

Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.


b.

Turn the power switch on (READY) and leave the vehicle as is until the electric current flowing into the auxiliary battery becomes 10 A or less.


c.
A174428E02
0.996,0.355 1.587,0.696 0.591,0.341 10 Probe Direction 0.182,1.489 1.180,1.997 0.998,0.508 10 Current Flowing from Auxiliary Battery 0.669,0.807 0.852,0.435 0.852,0.435 0.967,0.435 false

Change the orientation of the AC/DC400A probe.


d.

Measure the current flowing from the auxiliary battery with the power switch on (READY), headlight position switch and blower motor switch in the HI position, and rear window defogger turned on.

Standard Current:
Item Switch Condition Specified Condition
Current flowing from auxiliary battery Power switch on (READY)
(Headlight position switch and blower motor switch in HI position, rear window defogger on)
0 A or less
(No current from auxiliary battery)



e.

Turn the power switch off.