Home › Brake › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS › ELECTRONICALLY CONTROLLED BRAKE SYSTEM
RM2070E _54 Brake _061923 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS _0301683 ELECTRONICALLY CONTROLLED BRAKE SYSTEM D

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  ELECTRONICALLY CONTROLLED BRAKE SYSTEM  FREEZE FRAME DATA  


FREEZE FRAME DATA/INFORMATION


a.

Whenever an ABS, VSC or electronically controlled brake system DTC is detected, the skid control ECU stores the current vehicle (sensor) state as Freeze Frame Data.


b.

The skid control ECU stores the number of times (maximum: 31) the power switch has been turned from off (lock) to on (IG) since the last time the ABS was activated.


c.

For DTCs stored in the skid control ECU, information (INF) codes that are contained in the Freeze Frame Data can be displayed on the GTS.

HINT:
·

However, if the vehicle is stopped or at a low speed (7 km/h (4.3 mph) or less), or if a DTC is detected, the skid control ECU will stop counting the number of times the power switch has been turned from off (lock) to on (IG).

·

Freeze Frame Data at the time the ABS operates:

The skid control ECU stores and updates data whenever the ABS system operates.

When the ECU stores data at the time a DTC is detected, the data stored during ABS operation is cleared.

·

Freeze Frame Data at the time a DTC is detected:

When the skid control ECU stores data at the time a DTC is detected, no updates will be performed until the data is cleared.





CHECK FREEZE FRAME DATA AND INFORMATION


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Chassis / ABS/VSC/TRC / Trouble Codes.


e.

According to the display on the GTS, select the trouble code data display with Freeze Frame Data.


f.

Read the Freeze Frame Data recorded when the DTC was set.


g.

Read the information.

i.

Select the item that has an information (INF) code from the Freeze Frame Data screen.

ABS/VSC/TRC
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Detailed Freeze DTC Detailed code for Freeze Frame DTC / Min.: 0, Max.: 65535 - Number of information (INF) code output is displayed
Elapsed Time after Freeze Trigger Elapsed time after freeze trigger / Min.: 0 msec, Max.: 500 msec - -
Number of IG ON Number of operations of power switch on (IG) after storing Freeze Frame Data / 0 to 31 - -
Elapsed Time Elapsed time after power switch on (IG) / Min.: 0 sec., Max.: 100661 sec. - -
Buzzer Meter buzzer / ON or OFF ON: Buzzer on
OFF: Buzzer off
-
Stop Light SW Stop light switch / ON or OFF ON: Brake pedal depressed
OFF: Brake pedal released
-
Parking Brake SW Parking brake switch / ON or OFF ON: Parking brake applied
OFF: Parking brake released
-
Reservoir Warning SW Brake fluid level warning switch / ON or OFF ON: Reservoir level low
OFF: Reservoir level normal
-
Shift Lever Position Shift position information / Fail, 1st-6th/B, D/M, P,N or R Actual shift position -
Operated System Operated system status / ABS, VSC, TRC, BA, PB, PBA, HAB, HA-CTRL, TSC, Fail, Non or Sys - ABS: ABS activated
VSC: VSC activated
TRC: TRC activated
BA: BA activated
PB: PB activated
PBA: PBA activated
HAB: HAB activated
HA-CTRL: Hill-start assist control activated
TSC: TSC activated
Fail: Fail safe mode activated
Non: No system activated
Sys: System prohibited
Stroke Sensor Brake pedal stroke sensor / Min.: 0.00 V, Max.: 5.00 V When brake pedal released: 0.65 to 1.35 V Reading increases when brake pedal is depressed
Stroke Sensor2 Brake pedal stroke sensor 2 / Min.: 0.00 V, Max.: 5.00 V When brake pedal released: 3.65 to 4.35 V Reading decreases when brake pedal is depressed
Accumulator Sensor Accumulator pressure sensor / Min.: 0.00 V, Max.: 5.00 V Specified value: 2.90 to 4.20 V When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator
Yaw Rate Sensor Yaw rate sensor / Min.: -128 degrees/s, Max.: 127 degrees/s Vehicle stopped: 0 degrees/s
Turning right: -128 to 0 degrees/s
Turning left: 0 to 127 degrees/s
-
Lateral G Lateral G / Min.: -25.10 m/s2, Max.: 24.90 m/s2 - During turning: Changes in proportion with acceleration
Forward and Rearward G Forward and backward G / Min.: -25.10 m/s2, Max.: 24.90 m/s2 - During acceleration/deceleration: Changes in proportion with acceleration
FR Wheel Speed Front speed sensor RH / Min.: 0 km/h (0 mph), Max.: 326 km/h (202 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
FL Wheel Speed Front speed sensor LH / Min.: 0 km/h (0 mph), Max.: 326 km/h (202 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
RR Wheel Speed Rear speed sensor RH / Min.: 0 km/h (0 mph), Max.: 326 km/h (202 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
RL Wheel Speed Rear speed sensor LH / Min.: 0 km/h (0 mph), Max.: 326 km/h (202 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
Vehicle Speed Maximum wheel speed sensor / Min.: 0 km/h (0 mph), Max.: 326 km/h (202 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
Accelerator Opening Angle % The difference of a present accelerator / Min.: 0.0%, Max.: 127.0% When the accelerator pedal released: 0.0% During accelerator pedal operation: Changes in proportion with the pedal movement
ECB* Motor Relay ABS motor relay / ON or OFF ON: Relay on
OFF: Relay off
-
ECB* Main Relay ABS main relay / ON or OFF ON: Relay on
OFF: Relay off
-
IG1 Voltage Value IG1 voltage value / Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
IG2 Voltage Value IG2 voltage value / Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
BS1 Voltage Value BS voltage value / Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
VM1 Voltage Value VM1 voltage value / Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
Motor Relay Voltage Value Motor relay voltage value / Min.: 0.00 V, Max.: 20.00 V During motor operation: 12.00 V
No motor operation: 0.00 V
-
Steering Angle Sensor Steering angle sensor / Min.: - 3276.8 degrees, Max.: 3276.7 degrees Left turn: Increase
Right turn: Decrease
-
Regulator Pressure Sensor Output Regulator pressure sensor output / Min.: 0.00 V, Max.: 5.00 V When brake pedal released: 0.10 to 0.90 V Reading increases when brake pedal is depressed
Regulator Pressure Sensor Output Variant Regulator pressure sensor output variant / Min.: -30 MPa/s, Max.: 225 MPa/s - -
Wheel Cylinder Pressure Sensor Wheel cylinder pressure sensor / Min.: 0.00 V, Max.: 5.00 V When brake pedal released: 0.10 to 0.90 V Reading increases when brake pedal is depressed
SLA Solenoid Current Linear solenoid additional valve (SLA) current / Min.: 0.00 A, Max.: 1.50 A When brake pedal released: 0.00 A -
SLR Solenoid Current Linear solenoid reduction valve (SLR) current / Min.: 0.00 A, Max.: 1.50 A When brake pedal released: 0.00 A -
Target Oil Pressure Wheel target hydraulic pressure / Min.: 0.00 Mpa, Max.: 20.00 Mpa Changes according to the target wheel cylinder hydraulic pressure -
ECB* Solenoid (SSC) Simulator cut solenoid valve (SSC) / ON or OFF ON: Solenoid on
OFF: Solenoid off
-
ECB* Solenoid (SCC) Switching solenoid valve (SCC) / ON or OFF ON: Solenoid on
OFF: Solenoid off
-
ECB* Solenoid (SMC) Master cut solenoid valve (SMC) / ON or OFF ON: Solenoid on
OFF: Solenoid off
-
ECB* Solenoid (SRC) Regulator cut solenoid valve (SRC) / ON or OFF ON: Solenoid on
OFF: Solenoid off
-
Voltage of Stroke Sensor Voltage of brake pedal stroke sensor / Min.: -2.50 V, Max.: 2.49 V - -
Voltage of Stroke Sensor2 Voltage of brake pedal stroke sensor 2 / Min.: -2.50 V, Max.: 2.49 V - -

*: Electronically Controlled Brake System




CLEAR FREEZE FRAME DATA AND INFORMATION


NOTICE:

Clearing the DTCs will also clear the Freeze Frame Data and information (INF) codes.


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.