Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY › 2013.08–2014.11
RM2070E _57 Power Source / Network _061935 POWER DISTRIBUTION _0301752 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


PROCEDURE

Hide 82641 1.INSTALL NO. 1 INTEGRATION RELAY

a.

Connect the 3 connectors.


b.
E190797

Engage the 2 claws to install the No. 1 integration relay as shown in the illustration.


Hide 82662A 2.INSTALL NO. 1 RELAY BLOCK COVER

a.
E190795

Engage the 3 claws to install the No. 1 relay block cover as shown in the illustration.


Hide 3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).