The main body ECU (multiplex network body ECU) monitors communication between all the ECUs connected to the door bus lines. When the main body ECU (multiplex network body ECU) detects errors in communication with all the ECUs connected to the door bus lines at 2.6-second intervals and 3 times in a row, DTC B2325 will be stored.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B2325 | Main body ECU (multiplex network body ECU) detects errors in communication with the ECUs connected to the door bus lines 3 times in a row. | ·
Power window regulator motor assembly (for driver side) ·
Power window regulator motor assembly (for front passenger side) ·
Power window regulator motor assembly (for rear RH side) ·
Power window regulator motor assembly (for rear LH side) ·
Multiplex network master switch assembly ·
Roof sunshade ECU (sliding roof drive gear assembly)*1 ·
Double lock door control relay assembly*2 ·
Main body ECU (multiplex network body ECU) ·
Instrument panel junction block assembly ·
Wire harness or connector |
*1: w/ Roof Sunshade System
*2: w/ Double Locking System
When the roof sunshade ECU (sliding roof drive gear assembly) is replaced or removed and reinstalled, it requires initialization (See page Vehicle Interior>INTERIOR PANELS / TRIM>ROOF SUNSHADE SYSTEM>INITIALIZATION).
When a power window regulator motor assembly is replaced or removed and reinstalled, it requires initialization (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM>INITIALIZATION).
When using the GTS to troubleshoot with the power switch off:
Connect the GTS to the DLC3, and turn the courtesy switch on and off at 1.5-second intervals until communication between the GTS and vehicle begins.
Disconnect the O6*1 or N13*2 multiplex network master switch connector.
Disconnect the O2*1 or N2*2 power window regulator motor (for driver side) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O6-16 (LIN2) - O2-9 (LIN)*1
N13-16 (LIN2) - N2-9 (LIN)*2 |
Always | Below 1 Ω |
| O6-16 (LIN2) - Body ground*1
N13-16 (LIN2) - Body ground*2 |
Always | 10 kΩ or higher |
*1: for LHD
*2: for RHD
OK
NG
Remove the multiplex network master switch assembly (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 16 (LIN2) - 17 (LIN1) | Always | Below 1 Ω |
| 16 (LIN2) - Body ground | Always | 10 kΩ or higher |
| *1 | Component without harness connected
(Multiplex Network Master Switch Assembly) |
OK
NG
Remove the instrument panel junction block assembly (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
This inspection is to check the LIN line in the instrument panel junction block assembly that connects the wire harness to the built-in main body ECU (multiplex network body ECU).
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2D-26 (LIN2) - MB-16 (LIN2) | Always | Below 1 Ω |
| 2A-27 (LIN2) - MB-16 (LIN2) | Always | Below 1 Ω |
| 2A-27 (LIN2) - Body ground | Always | 10 kΩ or higher |
| *1 | Component without harness connected
(Instrument Panel Junction Block Assembly) |
*2 | Component without harness connected
(Instrument Panel Junction Block Assembly) |
| *3 | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
OK
NG
Disconnect the N2*1, O2*2, L145*3, z21*4, P4 and Q4 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2D-26 (LIN2) - Q4-9 (LIN) | Always | Below 1 Ω |
| 2A-27 (LIN2) - P4-9 (LIN) | Always | Below 1 Ω |
| 2A-27 (LIN2) - O6-17 (LIN1)*1
2A-27 (LIN2) - N13-17 (LIN1)*2 |
Always | Below 1 Ω |
| 2A-27 (LIN2) - N2-9 (LIN)*1
2A-27 (LIN2) - O2-9 (LIN)*2 |
Always | Below 1 Ω |
| 2A-27 (LIN2) - L145-9 (MPX1)*3 | Always | Below 1 Ω |
| 2A-27 (LIN2) - z21-4 (MPX1)*4 | Always | Below 1 Ω |
| 2D-26 (LIN2) - Body ground | Always | 10 kΩ or higher |
| 2A-27 (LIN2) - Body ground | Always | 10 kΩ or higher |
*1: for LHD
*2: for RHD
*3: w/ Double Locking System
*4: w/ Roof Sunshade System
OK
NG
Reconnect the O6*1, N13*2, L145*3, 2A, 2D, z21*4, P4, O2*1 and N2*2 connectors.
*1: for LHD
*2: for RHD
*3: w/ Double Locking System
*4: w/ Roof Sunshade System
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output | A |
| DTC B2325 is not output | B |
A
B
Reconnect the Q4 connector.
Disconnect the O6*1 or N13*2 connector.
*1: for LHD
*2: for RHD
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output | A |
| DTC B2325 is not output | B |
A
B
Reconnect the O6*1 or N13*2 connector.
*1: for LHD
*2: for RHD
Disconnect the P4 connector.
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output | A |
| DTC B2325 is not output | B |
A
B
Reconnect the P4 connector.
Disconnect the O2*1 or N2*2 connector.
*1: for LHD
*2: for RHD
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output | A |
| DTC B2325 is not output | B |
A
B
Reconnect the O2*1 or N2*2 connector.
Disconnect the N2*1 or O2*2 connector.
*1: for LHD
*2: for RHD
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output (w/ Roof Sunshade System) | A |
| DTC B2325 is output (w/ Double Locking System and w/o Roof Sunshade System) | B |
| DTC B2325 is output (w/o Double Locking System and w/o Roof Sunshade System) | C |
| DTC B2325 is not output | D |
A
B
C
D
Reconnect the N2*1 or O2*2 connector.
*1: for LHD
*2: for RHD
Disconnect the z21 connector.
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output (w/ Double Locking System) | A |
| DTC B2325 is output (w/o Double Locking System) | B |
| DTC B2325 is not output | C |
A
B
C
Reconnect the z21*1 connector.
*1: w/ Roof Sunshade System
Disconnect the L145 connector.
Clear the DTC (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>DTC CHECK / CLEAR).
After 10 seconds have elapsed, check if the trouble occurs again.
Check for DTCs again.
| Result | Proceed to |
|---|---|
| DTC B2325 is output | A |
| DTC B2325 is not output | B |
A
B