The power management control ECU will store this DTC when no signals can be received from the ECUs that have been memorized as those that are connected to sub bus 11.
When the power management control ECU receives a response signal from the ECUs connected to sub bus 11, the power management control ECU recognizes and memorizes that the ECU is connected to sub bus 11. Based on this memorized data, the power management control ECU monitors for malfunctions in the ECUs connected to sub bus 11 when communicating with those ECUs. If the power management control ECU cannot receive response signals from the ECUs that have been memorized as those connected to sub bus 11, the power management control ECU determines that a malfunction exists.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| U1002 | Power management control ECU cannot receive signals from all ECUs that have been memorized as those connected to sub bus 11. | ·
Open or short in sub bus 11 main line or connector ·
Open or short in sub bus 11 branch line or connector ·
Power management control ECU ·
Driving support ECU assembly*1 ·
Parking assist ECU*2 ·
Lane departure warning camera*3 ·
CAN No. 4 junction connector ·
CAN No. 1 junction terminal |
*1: w/ Pre-crash Safety System
*2: w/ Intelligent Parking Assist System
*3: w/ Lane Departure Alert System
This diagnosis procedure is for when DTC U1002 is output by the power management control ECU (GTS display: PM1 Gateway).
Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>HOW TO PROCEED WITH TROUBLESHOOTING).
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the power switch on (IG), wait at least 20 seconds, and then drive the vehicle at a speed of 50 km/h (31 mph) or more at least 1.72 seconds.
After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>DIAGNOSIS SYSTEM).
Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
Connectors that connect to the CAN junction connector can be distinguished by the color of their CAN bus lines. When the connectors have been disconnected from the CAN junction connector, reconnecting the connectors to non-original positions on the CAN junction connector does not affect system performance. However, it is preferred to reconnect the connectors to their original positions to avoid negative effects on the wiring such as tension on the wire harnesses, and to make future maintenance easier.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| *a | Component with harness connected
(Power Management Control ECU) |
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L5-34 (CA2H) - L5-35 (CA2L) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω | Below 54 Ω: Short circuit between bus lines |
| 70 Ω or higher: Open circuit in main bus lines | |||
| L5-34 (CA2H) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L5-35 (CA2L) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L5-34 (CA2H) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L5-35 (CA2L) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Open circuit in CAN main bus line) | B |
| NG (Short circuit between bus lines) | C |
·
NG (Ground short) ·
NG (+B short) |
D |
A
B
C
D
Reconnect the cable to the negative (-) auxiliary battery terminal.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Clear the DTCs.
Turn the power switch off.
Turn the power switch on (IG).
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC U1002 is output from the power management control ECU (GTS display: PM1 Gateway) | A |
| DTC U1002 is not output from the power management control ECU (GTS display: PM1 Gateway) | B |
A
B
(See pageGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING)
Disconnect the L5 power management control ECU connector.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-34 (CA2H) - L5-35 (CA2L) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
OK
NG
Reconnect the L5 power management control ECU connector.
Disconnect the L180 CAN No. 1 junction terminal.
| *a | Rear view of wire harness connector
(to CAN No. 1 Junction Terminal) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L180-3 (CANH) - L180-2 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
OK
NG
Reconnect the L180 CAN No. 1 junction terminal.
Disconnect the L181 and L184 CAN No. 4 junction connectors.
Measure the resistance according to the value(s) in the table below.
Distinguish between the connectors connected to the No. 4 CAN junction connector by checking the color of the communication wire.
Before disconnecting the connectors, make a note of where it is connected.
Reconnect the connector to its original position.
| *a | Vehicle wire harness connector connected to CAN junction connector | *b | Rear view of wire harness connector
(to No. 4 CAN Junction Connector) |
| Tester Connection | Wiring Color | Condition | Specified Condition | Connected to |
|---|---|---|---|---|
| L184-1 (CANH) - L184-2 (CANL) | B - G | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω | Power management control ECU |
| L181-1 (CANH) - L181-2 (CANL) | B - Y | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω | CAN No. 1 junction terminal |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Power management control ECU main line) | B |
| NG (CAN No. 1 junction terminal main line) | C |
A
B
C
Disconnect the L5 power management control ECU connector.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-34 (CA2H) - L5-35 (CA2L) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
OK
NG
Reconnect the L5 power management control ECU connector.
Disconnect the L184 CAN No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
Distinguish between the connectors connected to the No. 4 CAN junction connector by checking the color of the communication wire.
Before disconnecting the connectors, make a note of where it is connected.
Reconnect the connector to its original position.
| *a | Vehicle wire harness connector connected to CAN junction connector | *b | Rear view of wire harness connector
(to No. 4 CAN Junction Connector) |
| Tester Connection | Wiring Color | Condition | Specified Condition | Connected to |
|---|---|---|---|---|
| L184-1 (CANH) - L184-2 (CANL) | B - G | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω | Power management control ECU |
OK
NG
Reconnect the L184 CAN No. 4 junction connector.
| *a | Rear view of wire harness connector
(to No. 4 CAN Junction Connector) |
| *b | to Power Management Control ECU |
Connect the probes of an ohmmeter to terminals 1 (CANH) and 2 (CANL) of the power management control ECU main line harness connector.
While observing the resistance value shown on the ohmmeter, disconnect branch line connectors (L182, L183 and L185) from the CAN No. 4 junction connector until the resistance becomes normal (between 54 and 69 Ω).
| *a | Vehicle wire harness connector connected to CAN junction connector | *b | Rear view of wire harness connector
(to No. 4 CAN Junction Connector) |
| Tester Connection | Wiring Color | Condition | CAN No. 4 Junction Connector Side |
|---|---|---|---|
| L185-1 (CANH) - L185-2 (CANL) | B - W | Cable disconnected from negative (-) auxiliary battery terminal | Lane departure warning camera*1 |
| L184-1 (CANH) - L184-2 (CANL) | B - G | Cable disconnected from negative (-) auxiliary battery terminal | CAN main bus line (bus line connecting power management control ECU and CAN No. 1 junction terminal) |
| L183-1 (CANH) - L183-2 (CANL) | B - L | Cable disconnected from negative (-) auxiliary battery terminal | Parking assist ECU*2 |
| L182-1 (CANH) - L182-2 (CANL) | B - R | Cable disconnected from negative (-) auxiliary battery terminal | Driving support ECU assembly*3 |
| L181-1 (CANH) - L181-2 (CANL) | B - Y | Cable disconnected from negative (-) auxiliary battery terminal | CAN main bus line (bus line connecting CAN No. 4 junction connector and CAN No. 1 junction terminal) |
*1: w/ Lane Departure Alert System
*2: w/ Intelligent Parking Assist System
*3: w/ Pre-crash Safety System
Do not reconnect the disconnected connectors until this inspection is complete because there may be a short in 2 or more branch lines.
| Result | Proceed to |
|---|---|
| The resistance is still below 54 Ω when all the specified connectors are disconnected.
(There are no shorts between a pair of branch lines.) |
A |
| The resistance becomes normal (between 54 and 69 Ω) when a connector is disconnected.
(There is a short between one or more pairs of branch lines.) |
B |
When there is a short in one or more of the branch lines:
Reconnect all of the connectors to the CAN junction connector, except for the one that was disconnected last (the short-circuited bus line). Check that the resistance shown on the tester is normal (between 54 and 69 Ω) to confirm that there is a short in the one branch line only.
Distinguish between the connectors connected to the No. 4 CAN junction connector by checking the color of the communication wire.
Before disconnecting the connectors, make a note of where it is connected.
Reconnect the connector to its original position.
A
B
Disconnect the L181 CAN No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
Distinguish between the connectors connected to the No. 4 CAN junction connector by checking the color of the communication wire.
Before disconnecting the connectors, make a note of where it is connected.
Reconnect the connector to its original position.
| *a | Vehicle wire harness connector connected to CAN junction connector | *b | Rear view of wire harness connector
(to No. 4 CAN Junction Connector) |
| Tester Connection | Wiring Color | Condition | Specified Condition | Connected to |
|---|---|---|---|---|
| L184-1 (CANH) - L184-2 (CANL) | B - G | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω | Power management control ECU |
OK
NG
Reconnect the L181 CAN No. 4 junction connector.
Disconnect the L180 CAN No. 1 junction terminal.
| *a | Rear view of wire harness connector
(to CAN No. 1 Junction Terminal) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L180-3 (CANH) - L180-2 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
OK
NG
Reconnect the connector for the short-circuited branch line to the CAN junction connector (the connector that caused the bus line resistance to become normal (between 54 and 69 Ω) when it was disconnected).
Disconnect the connector that includes terminals CANH and CANL from the ECU to which the short-circuited branch line is connected (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>TERMINALS OF ECU).
Measure the resistance according to the value(s) in the table below.
| *a | Component with harness connector
(Power Management Control ECU) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L5-34 (CA2H) - L5-35 (CA2L) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
If the resistance changes to normal when the connector is disconnected from the ECU or sensor, there may be a short in the ECU or sensor.
OK
NG
Disconnect the L5 power management control ECU connector.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L5-34 (CA2H) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L5-35 (CA2L) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L5-34 (CA2H) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L5-35 (CA2L) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.
Find the necessary inspection from the Result column that matches the result in the Result column from the Check Sub Bus 11 inspection.
OK
NG
Disconnect the L184 CAN No. 4 junction connector.
| *a | Rear view of wire harness connector
(to CAN No. 4 Junction Connector) |
| *b | to Power Management Control ECU |
Before disconnecting the connector, make a note of where it is connected.
Reconnect the connector to its original position.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L5-34 (CA2H) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L5-35 (CA2L) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L5-34 (CA2H) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L5-35 (CA2L) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.
Find the necessary inspection from the Result column that matches the result in the Result column from the Check Sub Bus 11 inspection.
OK
NG
Reconnect the L184 CAN No. 4 junction connector.
Connect the probes of an ohmmeter to terminals CANH or CANL and GND (E1) or +B (AM22) of the power management control ECU.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
It is only necessary to perform the inspection for the result (short circuit) that was obtained in the Check Sub Bus 11 Line inspection.
Find the necessary inspection from the Result column that matches the result in the Result column from the Check Sub Bus 11 inspection.
While observing the resistance value shown on the ohmmeter, disconnect branch line connectors (L182, L183 and L185) from the CAN No. 4 junction connector until the resistance becomes normal (6 kΩ or higher (for +B short) or 200 Ω or higher (for ground short)).
| *a | Vehicle wire harness connector connected to CAN junction connector | *b | Rear view of wire harness connector
(to No. 4 CAN Junction Connector) |
| Tester Connection | Wiring Color | Condition | CAN No. 4 Junction Connector Side |
|---|---|---|---|
| L185-1 (CANH) - L185-2 (CANL) | B - W | Cable disconnected from negative (-) auxiliary battery terminal | Lane departure warning camera*1 |
| L184-1 (CANH) - L184-2 (CANL) | B - G | Cable disconnected from negative (-) auxiliary battery terminal | CAN main bus line (bus line connecting power management control ECU and CAN No. 1 junction terminal) |
| L183-1 (CANH) - L183-2 (CANL) | B - L | Cable disconnected from negative (-) auxiliary battery terminal | Parking assist ECU*2 |
| L182-1 (CANH) - L182-2 (CANL) | B - R | Cable disconnected from negative (-) auxiliary battery terminal | Driving support ECU assembly*3 |
| L181-1 (CANH) - L181-2 (CANL) | B - Y | Cable disconnected from negative (-) auxiliary battery terminal | CAN main bus line (bus line connecting CAN No. 4 junction connector and CAN No. 1 junction terminal) |
*1: w/ Lane Departure Alert System
*2: w/ Intelligent Parking Assist System
*3: w/ Pre-crash Safety System
| Result | Proceed to |
|---|---|
| The resistance between terminals CANH and +B, or the resistance between terminals CANL and +B is still below 6 kΩ when all the specified connectors are disconnected from the CAN junction connector.
(There is no short to +B in the branch lines.) |
A |
| The resistance between terminals CANH and GND, or the resistance between terminals CANL and GND is still below 200 Ω when all the specified connectors are disconnected from the CAN junction connector.
(There is no short to GND in the branch lines.) |
|
| The resistance between terminals CANH and +B, or the resistance between terminals CANL and +B becomes normal (6 kΩ or higher) when a connector is disconnected from the CAN junction connector.
(There is a short to +B in one of the areas related to one or more of the disconnected branch lines.) |
B |
| The resistance between terminals CANH and GND, or the resistance between terminals CANL and GND becomes normal (200 Ω or higher) when a connector is disconnected from the CAN junction connector.
(There is a short to GND in one of the areas related to one or more of the disconnected branch lines.) |
A
B
Disconnect the L181 CAN No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L5-34 (CA2H) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L5-35 (CA2L) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L5-34 (CA2H) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L5-35 (CA2L) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.
Find the necessary inspection from the Result column that matches the result in the Result column from the Check Sub Bus 11 inspection.
OK
NG
Reconnect the L181 CAN No. 4 junction connector.
Disconnect the L180 CAN No. 1 junction terminal.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L5-34 (CA2H) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L5-35 (CA2L) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L5-34 (CA2H) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L5-35 (CA2L) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.
Find the necessary inspection from the Result column that matches the result in the Result column from the Check Sub Bus 11 inspection.
OK
NG
Reconnect the connector for the bus line that is shorted to +B or GND to the CAN junction connector (the connector that caused the bus line resistance to change to 6 kΩ or higher (for +B short) or 200 Ω or higher (for ground short) when it was disconnected).
Disconnect the connector that includes terminals CANH and CANL from the ECU to which the bus line shorted to +B or GND is connected (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>TERMINALS OF ECU).
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L5-34 (CA2H) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L5-35 (CA2L) - L5-6 (E1) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L5-34 (CA2H) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L5-35 (CA2L) - L5-1 (AM22) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 11 inspection.
Find the necessary inspection from the Result column that matches the result in the Result column from the Check Sub Bus 11 inspection.
OK
NG