The power management control ECU will store this DTC when no signals can be received from the ECUs that have been memorized as those that are connected to sub bus 12.
When the power management control ECU receives a response signal from the ECUs connected to sub bus 12, the power management control ECU recognizes and memorizes that the ECU is connected to sub bus 12. Based on this memorized data, the power management control ECU monitors for malfunctions in the ECUs connected to sub bus 12 when communicating with those ECUs. If the power management control ECU cannot receive response signals from the ECUs that have been memorized as those connected to sub bus 12, the power management control ECU determines that a malfunction exists.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| U1002 | Power management control ECU cannot receive signals from all ECUs that have been memorized as those connected to sub bus 12. | ·
Open or short in sub bus 12 main line or connector ·
Open or short in sub bus 12 branch line or connector ·
Power management control ECU ·
ECM ·
Air conditioning amplifier assembly ·
Brake booster with master cylinder assembly (Skid control ECU) ·
CAN No. 1 junction connector ·
CAN No. 5 junction connector |
This diagnosis procedure is for when DTC U1002 is output by the power management control ECU (GTS display: PM2 Gateway).
Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>HOW TO PROCEED WITH TROUBLESHOOTING).
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the power switch on (IG) and wait at least 20 seconds.
After the repair, perform CAN Bus Check and check that all the ECUs and sensors connected to the CAN communication system are displayed (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>DIAGNOSIS SYSTEM).
Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L6-31 (CA3P) - L6-30 (CA3N) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω | Below 54 Ω:
Short circuit between bus lines |
| 70 Ω or higher:
Open circuit in a main bus line |
|||
| L6-31 (CA3P) - L6-4 (E12) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω:
CANH ground short |
| L6-30 (CA3N) - L6-4 (E12) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω:
CANL ground short |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| L6-31 (CA3P) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ:
CANH +B short |
| L6-30 (CA3N) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ:
CANL +B short |
| *a | Component with harness connector
(Power Management Control ECU) |
When the value is as specified, clear and recheck for DTCs. When no DTCs are output, check for malfunctions such as damage or improper connection of the relevant connectors.
| Result | Proceed to |
|---|---|
| OK | A |
| Open circuit in CAN main bus line | B |
| Short circuit between bus lines | C |
·
Ground short ·
+B short |
D |
A
B
C
D
Disconnect the power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L6-31 (CA3P) - L6-30 (CA3N) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
OK
NG
Reconnect the power management control ECU connector.
Disconnect the wire harness connector from the CAN No. 5 junction connector (instrument panel connector holder left side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L101-2 (CANH) - L101-4 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
| *b | to CAN No. 1 Junction Connector |
OK
NG
Reconnect the wire harness connector to the CAN No. 5 junction connector (instrument panel connector holder left side).
Disconnect the wire harness connector from the CAN No. 5 junction connector (instrument panel connector holder right side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L102-5 (CANH) - L102-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
| *b | to Power Management Control ECU |
OK
NG
Reconnect the wire harness connector to the CAN No. 5 junction connector (instrument panel connector holder left side).
Disconnect the wire harness connector from the CAN No. 1 junction connector (instrument panel wire side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L132-3 (CANH) - L132-9 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 1 Junction Connector) |
| *b | to CAN No. 5 Junction Connector |
OK
NG
Reconnect the wire harness connector to the CAN No. 1 junction connector (instrument panel wire side).
Disconnect the wire harness connector from the CAN No. 1 junction connector (engine room main wire side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A67-4 (CANH) - A67-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 1 Junction Connector) |
| *b | to ECM |
OK
NG
Reconnect the wire harness connector to the CAN No. 1 junction connector (engine room main wire side).
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A57-12 (CANP) - A57-4 (CANN) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to ECM) |
OK
NG
Disconnect the power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L6-31 (CA3P) - L6-30 (CA3N) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
OK
NG
Reconnect the power management control ECU connector.
Disconnect the wire harness connector from the CAN No. 5 junction connector (instrument panel connector holder right side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L102-5 (CANH) - L102-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
| *b | to Power Management Control ECU |
OK
NG
Disconnect the wire harness connector from the CAN No. 5 junction connector (instrument panel connector holder left side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L101-1 (CANH) - L101-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| L101-2 (CANH) - L101-4 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
| *b | to Air Conditioning Amplifier Assembly |
| *c | to CAN No. 1 Junction Connector |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (CAN No. 1 Junction connector main line) | B |
| NG (ECU branch line) | C |
A
B
C
Disconnect the wire harness connector from the CAN No. 1 junction connector (instrument panel wire side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L132-3 (CANH) - L132-9 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 1 MΩ or higher |
| *a | Front view of wire harness connector
(to CAN No. 1 Junction Connector) |
| *b | to CAN No. 5 Junction Connector |
OK
NG
Disconnect the wire harness connector from the CAN No. 1 junction connector (engine room main wire side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A67-3 (CANH) - A67-9 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| A67-4 (CANH) - A67-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to CAN No. 1 Junction Connector) |
| *b | to Brake booster with master cylinder assembly (Skid control ECU) |
| *c | to ECM |
OK
NG
Reconnect all wire harness connectors (CAN No. 1 junction connector and CAN No. 5 junction connector).
Disconnect the connector that includes terminals CANH and CANL from the ECU (or sensor) to which the short circuited branch line is connected (See page Power Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (w/o Central Gateway ECU)>TERMINALS OF ECU).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L6-31 (CA3P) - L6-30 (CA3N) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| *a | Component with harness connector
(Power Management Control ECU) |
If the resistance becomes normal (between 54 and 69 Ω) when the connector is disconnected from the ECU (or sensor), there may be a short in the ECU (or sensor).
If the resistance does not become normal (between 54 and 69 Ω) when the connector is disconnected from the ECU (or sensor), repair or replace the short circuited branch line or connector.
OK
NG
Disconnect the power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| L6-31 (CA3P) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | CAN No. 5 junction connector |
| L6-30 (CA3N) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| L6-31 (CA3P) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | |
| L6-30 (CA3N) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| *1 | DLC3 | - | - |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
- | - |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 12 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 12 inspection.
OK
NG
Disconnect the wire harness connector from the CAN No. 5 junction connector (instrument panel connector holder right side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| L102-5 (CANH) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | Power management control ECU |
| L102-3 (CANL) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| L102-5 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | |
| L102-3 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
*b | to Power management control ECU |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 12 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 12 inspection.
OK
NG
Disconnect the wire harness connector from the CAN No. 5 junction connector (instrument panel connector holder left side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| L101-1 (CANH) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | Air conditioning amplifier assembly |
| L101-3 (CANL) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| L101-2 (CANH) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | CAN No. 1 junction connector |
| L101-4 (CANL) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| L101-1 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Air conditioning amplifier assembly |
| L101-3 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| L101-2 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | CAN No. 1 junction connector |
| L101-4 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
*b | to Air conditioning amplifier assembly |
| *c | to CAN No. 1 Junction Connector | - | - |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (CAN No. 1 Junction connector main line) | B |
| NG (ECU branch line) | C |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 12 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 12 inspection.
A
B
C
Disconnect the wire harness connector from the CAN No. 1 junction connector (instrument panel wire side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| L132-3 (CANH) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | CAN No. 5 junction connector |
| L132-9 (CANL) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| L132-3 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | CAN No. 5 junction connector |
| L132-9 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 12 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 12 inspection.
| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector
(to CAN No. 1 Junction Connector) |
*b | to CAN No. 5 Junction Connector |
OK
NG
Disconnect the wire harness connector from the CAN No. 1 junction connector (engine room main wire side).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| A67-3 (CANH) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | Brake booster with master cylinder assembly (skid control ECU) |
| A67-9 (CANL) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| A67-4 (CANH) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANH ground short | ECM |
| A67-10 (CANL) - L61-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| A67-3 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Brake booster with master cylinder assembly (skid control ECU) |
| A67-9 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| A67-4 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | ECM |
| A67-10 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector
(to CAN No. 1 Junction Connector) |
*b | to Brake booster with master cylinder assembly (Skid control ECU) |
| *c | to ECM | - | - |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 12 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 12 inspection.
OK
NG
Reconnect all wire harness connectors (CAN No. 1 junction connector and CAN No. 5 junction connector).
Disconnect the connector that includes terminals CANH and CANL from the ECU to which the bus line shorted to +B or shorted to GND is connected.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose |
|---|---|---|---|
| L6-31 (CA3P) - L6-4 (E12) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω:
CANH ground short |
| L6-30 (CA3N) - L6-4 (E12) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher | Below 200 Ω:
CANL ground short |
| L6-31 (CA3P) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ:
CANH +B short |
| L6-30 (CA3N) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ:
CANL +B short |
| *a | Component with harness connector
(Power Management Control ECU) |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 12 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 12 inspection.
OK
NG