The main body ECU (multiplex network ECU) controls the footwell lights.
Inspect fuses for circuits related to this system before performing the following inspection procedure.
Check that the light intensity of the light control rheostat is set to maximum.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Check that the footwell lights come on.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Fr Foot Light | Footwell lights | ON/OFF | Precondition for using the Active Test to turn lights on and off:
·
Power switch is turned off just before performing the Active Test. |
Footwell lights come on.
OK
NG
for Front LH
Disconnect the L77*1 or L159*2 No. 1 interior illumination light assembly LH (footwell light) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L77-2 (B) - Body ground*1 | Power switch off | 11 to 14 V |
| L159-2 (B) - Body ground*2 | Power switch off | 11 to 14 V |
for Front RH
Disconnect the L1*1 or L158*2 No. 1 interior illumination light assembly RH (footwell light) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L1-2 (B) - Body ground*1 | Power switch off | 11 to 14 V |
| L158-2 (B) - Body ground*2 | Power switch off | 11 to 14 V |
*1: for LHD
*2: for RHD
OK
NG
for Front LH
Disconnect the 2B instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L77-1 (L) - 2B-18*1 | Always | Below 1 Ω |
| L77-1 (L) - Body ground*1 | Always | 10 kΩ or higher |
| L159-1 (L) - 2B-18*2 | Always | Below 1 Ω |
| L159-1 (L) - Body ground*2 | Always | 10 kΩ or higher |
for Front RH
Disconnect the 2B instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L1-1 (L) - 2B-17*1 | Always | Below 1 Ω |
| L1-1 (L) - Body ground*1 | Always | 10 kΩ or higher |
| L158-1 (L) - 2B-17*2 | Always | Below 1 Ω |
| L158-1 (L) - Body ground*2 | Always | 10 kΩ or higher |
*1: for LHD
*2: for RHD
OK
NG
Remove the instrument panel junction block assembly (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2B-17 - MB-26 (FSPT) | Always | Below 1 Ω |
| 2B-18 - MB-26 (FSPT) | Always | Below 1 Ω |
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
OK
NG