1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
58410B
2.REMOVE DECK BOARD ASSEMBLY
58411A
3.REMOVE NO. 1 DECK BOARD
58412A
4.REMOVE NO. 2 DECK BOARD
64993
5.REMOVE REAR DECK FLOOR BOX
64995
6.REMOVE DECK FLOOR BOX RH
7.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
8.REMOVE INTEGRATION CONTROL AND PANEL
55440D
9.REMOVE INSTRUMENT PANEL BOX ASSEMBLY
10.REMOVE CENTER INSTRUMENT PANEL REGISTER ASSEMBLY
55406B
11.REMOVE LOWER CENTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
55085
12.REMOVE NO. 2 HEATER TO REGISTER DUCT SUB-ASSEMBLY
55404D
13.REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
83809
14.REMOVE COMBINATION METER SUB-ASSEMBLY
Apply protective tape to the areas shown in the illustration.
| *1 | Protective Tape |
Remove the 4 screws.
Move the combination meter sub-assembly as shown in the illustration.
Disengage the clamp.
Disconnect each connector to remove the combination meter sub-assembly.