Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM › 2012.03–2013.08
RM2070E _59 Vehicle Exterior _061949 WINDOW / GLASS _0301864 POWER WINDOW CONTROL SYSTEM J

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  Driver Side Power Window does not Operate with Power Window Master Switch  


DESCRIPTION

When the hybrid control system is running or the power switch is on (IG), the power window regulator motor assembly (for driver door) is operated by the multiplex network master switch assembly. The power window regulator motor assembly (for driver door) has motor, regulator and ECU functions.

WIRING DIAGRAM

B234588E12
0.418,0.358 2.363,0.667 1.945,0.310 10 from Main Body ECU (Multiplex Network Body ECU) 0.971,1.561 2.627,1.724 1.656,0.162 10 : LIN Communication Line 0.831,1.981 1.593,2.144 0.762,0.162 10 *1: for LHD 0.831,2.332 1.593,2.494 0.762,0.162 10 *2: for RHD 2.531,1.853 3.343,1.994 0.812,0.141 10 O6*1, N13*2 2.532,2.005 4.564,2.317 2.032,0.312 10 Multiplex Network Master Switch Assembly 4.884,1.853 5.616,1.989 0.732,0.136 10 O2*1, N2*2 4.885,2.005 6.879,2.329 1.993,0.324 10 Power Window Regulator Motor Assembly (for Driver Door) 5.48,0.262 5.609,0.428 0.129,0.167 10 9 5.711,0.419 5.955,0.565 0.244,0.146 10 LIN 5.424,0.948 5.608,1.115 0.184,0.167 10 10 5.711,1.106 5.928,1.252 0.216,0.146 10 UP 5.494,1.299 5.597,1.443 0.103,0.144 10 7 5.711,1.456 6.168,1.602 0.457,0.146 10 DOWN 4.259,0.276 4.436,0.420 0.177,0.144 10 16 3.152,0.276 3.327,0.418 0.174,0.142 10 17 3.873,0.433 4.207,0.571 0.334,0.138 10 LIN2 4.259,0.948 4.458,1.115 0.199,0.167 10 20 3.971,1.106 4.185,1.243 0.214,0.138 10 UP 4.259,1.299 4.458,1.465 0.199,0.167 10 15 3.709,1.456 4.182,1.594 0.473,0.138 10 DOWN 3.424,0.433 3.759,0.571 0.334,0.138 10 LIN1

CAUTION / NOTICE / HINT

NOTICE:
·

The power window control system uses a LIN communication system. Inspect the communication function by following How to Proceed with Troubleshooting (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING). Troubleshoot the power window control system after confirming that the communication system is functioning properly.

·

If the power window regulator motor assembly (for driver door) has been replaced with a new one, initialize the power window control system (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM>INITIALIZATION).



PROCEDURE

1.READ VALUE USING GTS (Main Body)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Main Body / Data List.


e.

Read the Data List according to the display on the GTS.

Main Body
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Communication D-Door Motor Connection status between power window regulator motor (for driver door) and main body ECU (multiplex network body ECU) / STOP or OK STOP: Communication stopped
OK: Normal communication
-
Communication Master SW Connection status between multiplex network master switch assembly and main body ECU (multiplex network body ECU) / STOP or OK STOP: Communication stopped
OK: Normal communication
-

OK:

On the GTS screen, OK is displayed.




OK

2.READ VALUE USING GTS (D-Door Motor)

NG

GO TO LIN COMMUNICATION SYSTEM (Proceed to How to Proceed with Troubleshooting)

2.READ VALUE USING GTS (D-Door Motor)
a.

Enter the following menus: Body Electrical / D-Door Motor / Data List.


b.

Read the Data List according to the display on the GTS.

D-Door Motor
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
D Door P/W Up SW Driver door power window manual up switch signal / OFF or ON OFF: Driver door power window manual up switch not operated
ON: Driver door power window manual up switch operated
-
D Door P/W Down SW Driver door power window manual down switch signal / OFF or ON OFF: Driver door power window manual down switch not operated
ON: Driver door power window manual down switch operated
-

OK:

On the GTS screen, ON or OFF is displayed accordingly.




OK

3.PERFORM ACTIVE TEST USING GTS (D-Door Motor)

NG

4.CHECK HARNESS AND CONNECTOR (MASTER SWITCH - DRIVER DOOR MOTOR)
3.PERFORM ACTIVE TEST USING GTS (D-Door Motor)
a.

Enter the following menus: Body Electrical / D-Door Motor / Active Test.


b.

Perform the Active Test according to the display on the GTS.

CAUTION:

Be careful to avoid injuries as this test causes vehicle parts to move. During the Active Test, the jam protection function will not operate.


D-Door Motor
Tester Display Test Part Control Range Diagnostic Note
Power Window Power window OFF / UP / DOWN -

OK:

Driver door power window operates normally.




OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG

REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Door)

4.CHECK HARNESS AND CONNECTOR (MASTER SWITCH - DRIVER DOOR MOTOR)
a.

Disconnect the O6*1 or N13*2 multiplex network master switch assembly connector.


b.

Disconnect the O2*1 or N2*2 power window regulator motor assembly (for driver door) connector.

·

*1: for LHD

·

*2: for RHD



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD
Tester Connection Condition Specified Condition
O6-20 (UP) - O2-10 (UP) Always Below 1 Ω
O6-15 (DOWN) - O2-7 (DOWN) Always Below 1 Ω
O6-20 (UP) - Body ground Always 10 kΩ or higher
O6-15 (DOWN) - Body ground Always 10 kΩ or higher
O2-10 (UP) - Body ground Always 10 kΩ or higher
O2-7 (DOWN) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
N13-20 (UP) - N2-10 (UP) Always Below 1 Ω
N13-15 (DOWN) - N2-7 (DOWN) Always Below 1 Ω
N13-20 (UP) - Body ground Always 10 kΩ or higher
N13-15 (DOWN) - Body ground Always 10 kΩ or higher
N2-10 (UP) - Body ground Always 10 kΩ or higher
N2-7 (DOWN) - Body ground Always 10 kΩ or higher




OK

5.REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
a.

Replace the multiplex network master switch assembly (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>REMOVAL).



NEXT

6.CHECK MANUAL UP / DOWN FUNCTION (for Driver Door)
6.CHECK MANUAL UP / DOWN FUNCTION (for Driver Door)
a.

Check that the driver door power window moves when the manual up and down functions of the multiplex network master switch assembly are operated (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM>OPERATION CHECK).


OK:

Driver door manual up and down functions are normal.



OK

END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE)

NG

REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Door)