AIR CONDITIONING AMPLIFIER ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L17-1 (IG+) - L17-14 (GND) | P - W-B | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| L17-5 (TAM) - L17-13 (SG-2) | R - G | Ambient temperature sensor signal | Power switch on (IG)
Ambient temperature: 25°C (77°F) |
1.35 to 1.75 V |
| Power switch on (IG)
Ambient temperature: 40°C (104°F) |
0.9 to 1.2 V | |||
| L17-9 (PRE) - L17-13 (SG-2) | L - G | Air conditioning pressure sensor signal | A/C system operating
Refrigerant pressure: Abnormal pressure (more than 3.025 MPa (30.8 kgf/cm2, 439 psi)) |
4.69 V or higher |
| A/C system operating
Refrigerant pressure: Abnormal pressure (less than 0.167 MPa (1.7 kgf/cm2, 24 psi)) |
Below 0.70 V | |||
| A/C system operating
Refrigerant pressure: Normal pressure (less than 3.025 MPa (30.8 kgf/cm2, 439 psi) and more than 0.167 MPa (1.7 kgf/cm2, 24 psi)) |
0.70 to 4.69 V | |||
| L17-10 (S5-3) - L17-13 (SG-2) | LG - G | Power supply for air conditioning pressure sensor | Power switch on (IG) | 4.75 to 5.25 V |
| Power switch off | Below 1 V | |||
| L17-11 (CANH) - L17-12 (CANL) | B - W | CAN communication system | CAN communication circuit | Pulse generation |
| L17-13 (SG-2) - Body ground | G - Body ground | Ground for air conditioning pressure sensor, ambient temperature sensor | Always | Below 1 V |
| L17-14 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| L17-15 (ECOS) - L17-14 (GND) | V - W-B | Combination switch (ECO switch) signal | Power switch on (IG)
Combination switch (ECO switch) off |
11 to 14 V |
| Power switch on (IG)
Combination switch (ECO switch) on |
Below 1 V | |||
| L17-20 (RDFG) - L17-14 (GND) | SB - W-B | Rear defogger switch signal | Power switch on (IG)
Rear defogger switch off |
11 to 14 V |
| Power switch on (IG)
Rear defogger switch on |
Below 1 V | |||
| L17-21 (B) - L17-14 (GND) | Y - W-B | Power source (Back-up) | Power switch off | 11 to 14 V |
| L17-23 (BLW) - L17-14 (GND) | L - W-B | Blower motor speed control signal | Power switch on (IG)
Blower switch: LO |
Pulse generation
(See waveform 1) |
| L17-29 (TR) - L17-34 (SG-1) | Y - L | Room temperature sensor signal | Power switch on (IG)
Cabin temperature: 25°C (77°F) |
1.8 to 2.2 V |
| Power switch on (IG)
Cabin temperature: 40°C (104°F) |
1.2 to 1.6 V | |||
| L17-33 (TS) - L17-14 (GND) | GR - W-B | Solar sensor signal | Power switch on (IG)
Solar sensor subjected to electric light |
0.8 to 4.3 V |
| Power switch on (IG)
Solar sensor covered with a cloth |
Below 0.8 V | |||
| L17-34 (SG-1) - Body ground | L - Body ground | Ground for room temperature sensor | Always | Below 1 V |
| L17-37 (LIN1) - L17-14 (GND) | V - W-B | LIN communication signal | Power switch on (IG) | Pulse generation |
| z11-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z11-3 (BUS) - z11-2 (BUS G) | - | BUS IC control signal | Power switch on (IG) | Pulse generation |
| z11-4 (B BUS) - z11-2 (BUS G) | - | Power supply for BUS IC | Power switch off | 11 to 14 V |
| z11-5 (SGA) - Body ground | - | Ground for evaporator temperature sensor | Always | Below 1 V |
| z11-6 (TEA) - z11-5 (SGA) | - | Evaporator temperature sensor signal | Power switch on (IG)
Evaporator temperature: 0°C (32°F) |
2.0 to 2.4 V |
| Power switch on (IG)
Evaporator temperature: 15°C (59°F) |
1.4 to 1.8 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | L17-23 (BLW) - L17-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Vehicle Condition | Power switch on (IG)
Blower switch: LO |
CENTER CLUSTER MODULE CIRCUIT (AIR CONDITIONING CONTROL ASSEMBLY)
Check from the rear of the connector while it is connected to the center cluster module circuit (air conditioning control assembly).
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L20-1 (GND) - Body ground | W-B - Body ground | Ground for center cluster module circuit (air conditioning assembly) | Always | Below 1 V |
| L20-3 (TX+) - Body ground | V - Body ground | LIN communication signal | Power switch on (IG) | Pulse generation |
| L20-7 (ILL+) - L20-12 (ILL-) | P - W-B | Light control switch signal | Light control switch tail or head position | 11 to 14 V |
| Light control switch off | Below 1 V | |||
| L20-16 (IG+) - Body ground | Y - Body ground | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V |
HYBRID VEHICLE CONTROL ECU (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>TERMINALS OF ECU)