This DTC is stored when refrigerant pressure on the high pressure side is extremely low (0.176 MPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPa (30.8 kgf/cm2, 439 psi) or more). The air conditioning pressure sensor is installed on the high pressure line. It detects refrigerant pressure to output a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics to control the compressor.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1423/23 | ·
Open or short in pressure sensor circuit ·
Refrigerant pressure on the high pressure line is extremely low (0.176 MPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPa (30.8 kgf/cm2, 439 psi) or more). |
·
Air conditioning pressure sensor ·
Harness or connector between air conditioning pressure sensor and air conditioning amplifier assembly ·
Air conditioning amplifier assembly ·
Expansion valve (blocked, stuck) ·
Condenser assembly (blocked, deterioration of cooling capacity due to dirt) ·
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed) ·
Cooling fan system (condenser cannot be cooled down) ·
A/C system (leaks, blocked) |
Disconnect the A31 air conditioning pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |
| *a | Front view of wire harness connector
(to Air Conditioning Pressure Sensor) |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-1 (-) - Body ground | Always | Below 1 Ω |
OK
NG
Reconnect the A31 air conditioning pressure sensor connector.
Remove the air conditioning amplifier assembly with the connectors still connected.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L17-9 (PRE) - Body ground | Power switch on (IG)
(A/C switch: off) |
0.70 to 4.69 V |
If the voltage is not as specified, there may be a malfunction in the air conditioning amplifier assembly, A/C pressure sensor or wire harness. It is also possible that the amount of refrigerant may not be appropriate.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
OK
NG
Turn the power switch on (READY).
Measure the voltage when the following conditions are met:
| Item | Condition |
|---|---|
| Vehicle Doors | Fully open |
| Compressor speed | 5200 rpm |
| Temperature Setting | MAX COLD |
| Blower Speed | HI |
| A/C Switch | On |
| R/F Switch | RECIRCULATION |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure in the high pressure line becomes extremely high during the inspection (if the voltage exceeds 4.69 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage over a period of time (approximately 10 minutes) because the problem symptom may recur after a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L17-9 (PRE) - Body ground | Power switch on (IG)
(A/C: on) |
0.70 to 4.69 V |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
A
B
(See pageVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>PROBLEM SYMPTOMS TABLE)
C
Disconnect the L17 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-3 (+) - L17-10 (S5-3) | Always | Below 1 Ω |
| L17-10 (S5-3) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the L17 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-1 (-) - L17-13 (SG-2) | Always | Below 1 Ω |
| L17-13 (SG-2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the L17 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-2 (PR) - L17-9 (PRE) | Always | Below 1 Ω |
| A31-2 (PR) - Body ground | Always | 10 kΩ or higher |
OK
NG
Install the manifold gauge set.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
Evacuate the A/C system and check that vacuum can be maintained.
Vacuum can be maintained in the A/C system.
If vacuum cannot be maintained in the A/C system, there may be a refrigerant leak. In this case, it is necessary to repair or replace the leaking part of the A/C system.
OK
NG
Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT).
NEXT
Turn the power switch on (READY).
Recheck for the DTC when the following conditions are met:
| Item | Condition |
|---|---|
| Vehicle Doors | Fully open |
| Compressor Speed | 5200 rpm |
| Temperature Setting | MAX COLD |
| Blower Speed | HI |
| A/C Switch | On |
| R/F Switch | RECIRCULATION |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because this DTC may be stored after the A/C has been operating for a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
| Result | Proceed to |
|---|---|
| DTC B1423/23 is output | A |
| DTC B1423/23 is not output | B |
If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair any refrigerant leaks as necessary.
A
B
Install the manifold gauge set.
Reconnect the air conditioning pressure sensor connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L17-9 (PRE) - L17-13 (SG-2) | Refrigerant pressure:
Normal pressure (0.176 to 3.065 MPa [26 to 439 psi]) |
0.70 to 4.69 V |
The A/C pressure sensor power source voltage is 5 V.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
OK
NG
Identify the area where refrigerant leaks from (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT).
Repair the identified area of the A/C system.
Evacuate the A/C system.
A
Check that the cooling fan(s) operates normally.
Refer to Cooling Fan Circuit (See page Engine / Hybrid System>2ZR-FXE (COOLING)>COOLING FAN SYSTEM>ON-VEHICLE INSPECTION).
OK
NG
Use a refrigerant recovery unit to recover refrigerant.
Evacuate the A/C system.
Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT).
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTCs.
NEXT
Turn the power switch on (READY).
Recheck for the DTC when the following conditions are met:
| Item | Condition |
|---|---|
| Vehicle Doors | Fully open |
| Compressor Speed | 5200 rpm |
| Temperature Setting | MAX COLD |
| Blower Speed | HI |
| A/C Switch | On |
| R/F Switch | RECIRCULATION |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because DTC may be stored after the A/C has been operating for a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant. In this case, to complete the repair, it is necessary to replace the cooler dryer.
| Result | Proceed to |
|---|---|
| DTC B1423/23 is output | A |
| DTC B1423/23 is not output | B |
A
B
Replace the expansion valve with a new or known good one (See page Vehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL).
Replace the expansion valve with a new or known good one because the expansion valve is either stuck or clogged.
NEXT
Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>REPLACEMENT).
NEXT
Turn the power switch on (READY).
Recheck for the DTC when the following conditions are met:
| Item | Condition |
|---|---|
| Vehicle Doors | Fully open |
| Compressor Speed | 5200 rpm |
| Temperature Setting | MAX COLD |
| Blower Speed | HI |
| A/C Switch | On |
| R/F Switch | RECIRCULATION |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because this DTC may be stored after the A/C has been operating for a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
If refrigerant pressure is not normal after replacing the expansion valve with a new or known good one, the condenser or pipes may be clogged with dirt, dust or other contaminants. In this case, clean or replace the condenser or pipes.
| Result | Proceed to |
|---|---|
| DTC B1423/23 is not output | A |
| DTC B1423/23 is output | B |
A
B
Replace the air conditioning pressure sensor (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING PRESSURE SENSOR>REMOVAL).
Since the air conditioning pressure sensor cannot be inspected while it is removed from the vehicle, replace the air conditioner pressure sensor with a new or known good one and check that the condition returns to normal.
NEXT
Turn the power switch on (READY).
Recheck for the DTC when the following conditions are met:
| Item | Condition |
|---|---|
| Vehicle Doors | Fully open |
| Compressor Speed | 5200 rpm |
| Temperature Setting | MAX COLD |
| Blower Speed | HI |
| A/C Switch | On |
| R/F Switch | RECIRCULATION |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure in the high pressure line is excessive, this DTC will be stored. Therefore, it is necessary to measure the voltage over a period of time (approximately 10 minutes) because this DTC may be stored after the A/C has been operating for a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to signals from the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
| Result | Proceed to |
|---|---|
| DTC B1423/23 is not output | A |
| DTC B1423/23 is output | B |
A
B