Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P321F-319    Part of HV Gate Blocking Range/Performance

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P321E-318 .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P321F
319
An open or ground short in the HV gate block signal circuit when the gate is operating
When the HV gate block function check is performed (when the ignition switch is turned from on (READY) to off), the inverter voltage (VH) drops and current flows in the inverter. (Either generator (MG1) or motor (MG2) is malfunctioning.)
(1 trip detection logic)
Inverter with converter assembly

Related Data List 
DTC No.
Data List
P321F-319
  1. VH-Voltage after Boosting
  2. Ready Signal
  3. Emergency Shutdown

INSPECTION PROCEDURE

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Wait for 30 seconds or more with the vehicle stopped, the ignition switch to ON (READY) and the shift lever in P. Then turn the power switch off and wait for 60 seconds or more.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P321E-318 is not output.
    A
    P321E-318 is also output.
    B

  1. Turn the ignition switch off.



B
GO TO DTC CHART (P321E-318) (Click here)
A

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)