DTC P321F-319 Part of HV Gate Blocking Range/Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P321F | 319 | An open or ground short in the HV gate block signal circuit when the gate is operating When the HV gate block function check is performed (when the ignition switch is turned from on (READY) to off), the inverter voltage (VH) drops and current flows in the inverter. (Either generator (MG1) or motor (MG2) is malfunctioning.) (1 trip detection logic) | Inverter with converter assembly |
| DTC No. | Data List |
| P321F-319 |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P321E-318 is not output. | A |
| P321E-318 is also output. | B |
Turn the ignition switch off.
|
| ||||
| A | ||
| ||