DTC P0A60-288 Drive Motor "A" Phase V Current |
DTC P0A60-290 Drive Motor "A" Phase V Current |
DTC P0A60-294 Drive Motor "A" Phase V Current |
DTC P0A60-501 Drive Motor "A" Phase V Current |
DTC P0A63-296 Drive Motor "A" Phase W Current |
DTC P0A63-298 Drive Motor "A" Phase W Current |
DTC P0A63-302 Drive Motor "A" Phase W Current |
DTC P0A63-502 Drive Motor "A" Phase W Current |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A60 | 288 | Malfunction in motor inverter current sensor (phase V sub sensor)* (1 trip detection logic) | Inverter with converter assembly |
| 290 | Malfunction in motor inverter current sensor (phase V main sensor)* (1 trip detection logic) | ||
| 294 | Malfunction in motor inverter current sensor (performance problem or open of phase V sensors)* Detects an abnormal condition when the difference between the output of the phase V main sensor and phase V sub sensor is larger than the standard. (1 trip detection logic) | ||
| 501 | Malfunction in motor inverter current sensor (phase V main and sub sensors offset)* (1 trip detection logic) | ||
| P0A63 | 296 | Malfunction in motor inverter current sensor (phase W sub sensor)* (1 trip detection logic) | |
| 298 | Malfunction in motor inverter current sensor (phase W main sensor)* (1 trip detection logic) | ||
| 302 | Malfunction in motor inverter current sensor (performance problem or open of phase W sensors)* Detects an abnormal condition when the difference between the output of the phase W main sensor and phase W sub sensor is larger than the standard. (1 trip detection logic) | ||
| 502 | Malfunction in motor inverter current sensor (phase W main and sub sensors offset)* (1 trip detection logic) |
| Related DTCs | P0A60 (INF 288/290/294/501): Drive Motor "A" Phase V Current P0A63 (INF 296/298/302/502): Drive Motor "A" Phase W Current |
| Required sensors / components | Motor inverter current sensor, Motor resolver |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Power management control ECU | DTC P0A60 (INF 288/ 290/ 294/ 501) is not detected DTC P0A63 (INF 296/ 298/ 302/ 502) is not detected |

| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A60 or P0A63 is output, or DTCs other than the ones in the table below are also output. | A |
| P0A78-202 is output. | B |
Turn the ignition switch off.
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | ||
| ||