Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A72-326    Generator Phase V Current

DTC    P0A72-328    Generator Phase V Current

DTC    P0A72-333    Generator Phase V Current

DTC    P0A72-515    Generator Phase V Current

DTC    P0A75-334    Generator Phase W Current

DTC    P0A75-336    Generator Phase W Current

DTC    P0A75-341    Generator Phase W Current

DTC    P0A75-516    Generator Phase W Current

for Preparation Click here


DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors the generator inverter current sensors. P0A72 and P0A75 indicate malfunctions in the current sensors, and they do not indicate malfunctions in the high-voltage system.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A72
326
Malfunction in generator inverter current sensor (phase V sub sensor)*
(1 trip detection logic)
Inverter with converter assembly
328
Malfunction in generator inverter current sensor (phase V main sensor)*
(1 trip detection logic)
333
Malfunction in generator inverter current sensor (performance problem or open of phase V sensors)*
Detects an abnormal condition when the difference between the output of the phase V main sensor and phase V sub sensor is larger than the standard.
(1 trip detection logic)
515
Malfunction in generator inverter current sensor (phase V main and sub sensors offset)*
(1 trip detection logic)
P0A75
334
Malfunction in generator inverter current sensor (phase W sub sensor)*
(1 trip detection logic)
336
Malfunction in generator inverter current sensor (phase W main sensor)*
(1 trip detection logic)
341
Malfunction in generator inverter current sensor (performance problem or open of phase W sensors)*
Detects an abnormal condition when the difference between the output of the phase W main sensor and phase W sub sensor is larger than the standard.
(1 trip detection logic)
516
Malfunction in generator inverter current sensor (phase W main and sub sensors offset)*
(1 trip detection logic)
  1. *: Stores a DTC when the current sensor signal is out of the normal range.

MONITOR DESCRIPTION

The power management control ECU monitors the generator inverter current sensor. If the power management control ECU detects a current sensor fault, it will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A72 (INF 326/328/333/515): Generator Phase V Current
P0A75 (INF 334/336/341/516): Generator Phase W Current
Required sensors / components
Generator inverter current sensor, generator resolver
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU
DTC P0A72 (INF 326/328/333/515) is not detected
DTC P0A75 (INF 334/336/341/516) is not detected

CONFIRMATION DRIVING PATTERN


A308309E01

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the ignition switch off and wait for 30 seconds or more.
  5. Turn the ignition switch to ON (IG) and wait for 5 seconds or more.
  6. Turn the Techstream on.
  7. Turn the ignition switch to ON (READY) with the shift lever in P and wait for 5 seconds or more.
  8. Move the shift lever to N and wait for 5 seconds or more.
  9. Depress the accelerator pedal of the vehicle with the engine stopped and shift lever in P to start the engine.
  10. Drive the vehicle forward with shift lever in D for 5 m or more.[A]
  11. Drive the vehicle backward with shift lever in R for 5 m or more.[B]
  12. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.[C]
  13. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.

  14. Check that permanent DTCs are cleared. If no permanent DTC is output, the system is normal.
  15. If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the ignition switch to ON (IG) and wait for 5 seconds or more.
  2. Turn the ignition switch to ON (READY) with the shift lever in P and wait for 5 seconds or more.
  3. Move the shift lever to N and wait for 5 seconds or more.
  4. Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
  5. Drive the vehicle forward with the shift lever in D for 5 m or more.
  6. Drive the vehicle backward with the shift lever in R for 5 m or more.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    Only P0A72 or P0A75 is output, or DTCs other than the ones in the table below are also output.
    A
    P0A7A-203 is output.
    B

  1. Turn the ignition switch off.



B
GO TO DTC CHART (P0A7A-203) (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A267460
  1. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

    NOTICE:
    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

    OK:
    The connectors are connected securely and there are no contact pressure problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)