LIGHTING SYSTEM > Interior Light Auto Cut Circuit |

| 1.PERFORM ACTIVE TEST USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Check that the relay operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Relay for Interior Light Auto Cut Function | DOME CUT Relay | ON/OFF | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT DOME CUT RELAY |
Remove the DOME CUT relay from the No. 2 engine room relay block and No. 2 junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Voltage is applied between terminals 1 and 2 | Below 1 Ω |
| *a | Component without harness connected (DOME CUT Relay) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)) |
Disconnect the G59 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Relay terminal 1 - G59-15 (DOMR) | Always | Below 1 Ω |
| Relay terminal 1 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||