Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    U029A-123    Lost Communication with Hybrid Battery Pack Sensor Module

for Preparation Click here


DESCRIPTION

The battery smart unit detects the HV battery conditions (voltage, current, and temperature) and battery cooling fan voltage, and sends the detected signals to the power management control ECU via serial communication.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
U029A
123
Serial communication error between the power management control ECU and battery smart unit: The power management control ECU cannot receive signals from the battery smart unit correctly.
(1 trip detection logic)
  1. Wire harness or connector
  2. Power management control ECU
  3. Battery smart unit

MONITOR DESCRIPTION

If the power management control ECU detects problem with serial communication with the battery smart unit, it will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
U029A (INF 123): Battery smart unit communication malfunction
Required sensors / components
Battery smart unit
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
TMC's intellectual property
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Battery smart unit
DTC U029A (INF 123) is not detected

CONFIRMATION DRIVING PATTERN

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the ignition switch off.
  5. Turn the ignition switch to ON (READY) and turn the Techstream on.
  6. Perform a universal trip.
  7. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
  8. Check that permanent DTCs are cleared.

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


WIRING DIAGRAM


A279002E01


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the ignition switch to ON (IG) and wait for 2 minutes or more.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check and record any HV system DTCs, INF codes and freeze frame data.

  1. Check for DTCs (Click here).

    Result:
    Result
    Proceed to
    Only U029A-123 is output.
    A
    DTCs other than U029A-123 are also output.
    B

  1. Turn the ignition switch off.

  1. Disconnect the Techstream from the DLC3.



B
GO TO DTC CHART (HYBRID BATTERY SYSTEM) (Click here)
A


2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector G57 from the power management control ECU (Click here).

  1. Remove the No. 1 hybrid battery exhaust duct .

  1. Disconnect connector M39 from the battery smart unit.



    A260175E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    G57-32 (BTH+) - M39-1 (BTH+)
    Ignition switch off
    Below 1 Ω
    G57-33 (BTH-) - M39-4 (BTH-)
    Ignition switch off
    Below 1 Ω
    M39-1 (BTH+) - M39-6 (GND) and Body ground
    Ignition switch off
    10 kΩ or higher
    M39-4 (BTH-) - M39-6 (GND) and Body ground
    Ignition switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *b
    Rear view of wire harness connector
    (to Battery Smart Unit)



    A263816E01
  1. Remove the IG2 No. 2 fuse, IGCT No. 2 fuse, AM2 fuse from the No. 2 engine room relay block and No. 2 junction block assembly. (w/ smart key system)
    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IG2 No. 2 fuse
    *3
    IGCT No. 2 fuse
    *4
    AM2 fuse



    A263813E01
  1. Remove the IG2 No. 2 fuse, IGCT No. 2 fuse, ECU-B No. 2 fuse from the No. 2 engine room relay block and No. 2 junction block assembly. (w/o smart key system)
    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IG2 No. 2 fuse
    *3
    IGCT No. 2 fuse
    *4
    ECU-B No. 2 fuse

  1. Disconnect all connectors from the power management control ECU.



  1. Measure the resistance according to the value(s) in the table below. (w/ smart key system)


    A245299E22


    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    -
    -

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    G57-32 (BTH+) - G58-7 (AM21)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - G57-1 (AM22)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A38-2 (+B2)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-5 (+B1)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-6 (MREL)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-1 (IG2)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - G58-1 (ACCD)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) G58-2 (IG1D)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-2 (IG2D)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - G57-14 (SPDI)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G58-7 (AM21)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G57-1 (AM22)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A38-2 (+B2)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-5 (+B1)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-6 (MREL)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-1 (IG2)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G58-1 (ACCD)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G58-2 (IG1D)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-2 (IG2D)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G57-14 (SPDI)
    Ignition switch off
    10 kΩ or higher

    NOTICE:
    When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



  1. Measure the resistance according to the value(s) in the table below. (w/o smart key system)


    A245299E23


    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    -
    -

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    G57-32 (BTH+) - G57-1 (BATT)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A38-2 (+B2)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-5 (+B1)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-6 (MREL)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - A39-1 (IG2)
    Ignition switch off
    10 kΩ or higher
    G57-32 (BTH+) - G57-14 (SPDI)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G57-1 (BATT)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A38-2 (+B2)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-5 (+B1)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-6 (MREL)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - A39-1 (IG2)
    Ignition switch off
    10 kΩ or higher
    G57-33 (BTH-) - G57-14 (SPDI)
    Ignition switch off
    10 kΩ or higher

    NOTICE:
    When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

  1. Connect the battery smart unit connector.

  1. Install the No. 1 hybrid battery exhaust duct.

  1. Connect the power management control ECU connectors.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY SMART UNIT)
OK


3.CHECK POWER MANAGEMENT CONTROL ECU

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct .

  1. Disconnect connector M39 from the battery smart unit.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A260173E03
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    M39-1 (BTH+) - M39-6 (GND)
    Ignition switch ON (IG)
    2.3 to 2.7 V
    M39-4 (BTH-) - M39-6 (GND)
    Ignition switch ON (IG)
    2.3 to 2.7 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)

NOTICE:
Turning the ignition switch to ON (IG) with the battery smart unit connector and power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.



    A260173E04
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    M39-1 (BTH+) - M39-4 (BTH-)
    Ignition switch off
    4.4 to 5.4 kΩ

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)

    HINT:
    Resistance becomes 2.0 kΩ or less when there is a short circuit in the power management control ECU.

  1. Connect the battery smart unit connector.

  1. Install the No. 1 hybrid battery exhaust duct.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK

REPLACE BATTERY SMART UNIT (Click here)