Terminal No. (Symbol)
| Wiring Color
| Terminal Description
| Condition
| Specified Condition
|
G34-1 (IG+) - G34-14 (GND)
| V - W-B
| Power source (IG)
| Ignition switch ON (IG)
| 11 to 14 V
|
G34-1 (IG+) - G34-14 (GND)
| V - W-B
| Power source (IG)
| Ignition switch off
| Below 1 V
|
G34-3 (PTC3) - G34-14 (GND)*1
| R - W-B
| Quick heater operation signal
| - Ignition switch ON (READY)
- ECO mode switch (eco switch assembly) off
- Blower motor on
- Temperature settings: MAX HOT
- Engine coolant temperature approximately 50°C lower
- Ambient temperature 10°C or lower
- IDH terminal signal less than 1 V (Inverter with converter assembly overload not detected)
| Below 1 V
|
G34-4 (ECOS) - G34-14 (GND)
| R - W-B
| ECO mode switch (eco switch assembly) signal
| - Ignition switch ON (IG)
- ECO mode switch (eco switch assembly): on
| Below 1 V
|
G34-4 (ECOS) - G34-14 (GND)
| R - W-B
| ECO mode switch (eco switch assembly) signal
| - Ignition switch ON (IG)
- ECO mode switch (eco switch assembly): off
| 11 to 14 V
|
G34-5 (TAM) - G34-13 (SG-2)
| W - B
| Ambient temperature sensor signal
| - Ignition switch ON (IG)
- Ambient temperature: 25°C (77°F)
| 1.8 to 2.2 V
|
G34-5 (TAM) - G34-13 (SG-2)
| W - B
| Ambient temperature sensor signal
| - Ignition switch ON (IG)
- Ambient temperature: 40°C (104°F)
| 0.9 to 1.2 V
|
G34-9 (PRE) - G34-13 (SG-2)
| GR - B
| Air conditioning pressure sensor signal
| - Ignition switch ON (READY)
- A/C system operating
- Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.8 kgf/cm2, 439 psi))
| 4.62 V or higher
|
G34-9 (PRE) - G34-13 (SG-2)
| GR - B
| Air conditioning pressure sensor signal
| - Ignition switch ON (READY)
- A/C system operating
- Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 25 psi))
| Below 0.74 V
|
G34-9 (PRE) - G34-13 (SG-2)
| GR - B
| Air conditioning pressure sensor signal
| - Ignition switch ON (READY)
- A/C system operating
- Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
| 0.74 to 4.62 V
|
G34-10 (S5-3) - G34-13 (SG-2)
| Y - B
| Power supply for air conditioning pressure sensor
| Ignition switch ON (IG)
| 4.75 to 5.25 V
|
G34-10 (S5-3) - G34-13 (SG-2)
| Y - B
| Power supply for air conditioning pressure sensor
| Ignition switch off
| Below 1 V
|
G34-11 (CANH) - G34-12 (CANL)
| V - W
| CAN communication system
| CAN communication occurring
| Pulse generation
|
G34-13 (SG-2) - Body ground
| B - Body ground
| Ground for air conditioning pressure sensor, ambient temperature sensor
| Always
| Below 1 V
|
G34-14 (GND) - Body ground
| W-B - Body ground
| Ground for main power supply
| Always
| Below 1 V
|
G34-21 (B) - G34-14 (GND)
| BE - W-B
| Power source (Back-up)
| Ignition switch off
| 11 to 14 V
|
G34-22 (BLW) - G34-14 (GND)
| R - W-B
| Blower motor speed control signal
| - Ignition switch ON (IG)
- Blower switch: LO
| Pulse generation (See waveform 1)
|
G34-27 (IDH) - G34-14 (GND)*1
| L - W-B
| Inverter with converter assembly current over signal
| Ignition switch ON (IG) (inverter with converter assembly overload not detected)
| less than 1 V
|
G34-29 (TR) - G34-34 (SG-1)
| P - SB
| Room temperature sensor signal
| - Ignition switch ON (IG)
- Cabin temperature: 25°C (77°F)
| 1.8 to 2.2 V
|
G34-29 (TR) - G34-34 (SG-1)
| P - SB
| Room temperature sensor signal
| - Ignition switch ON (IG)
- Cabin temperature: 40°C (104°F)
| 1.2 to 1.6 V
|
G34-30 (S5-4) - G34-14 (GND)
| R - W-B
| Power supply for solar sensor
| Ignition switch ON (IG)
| 4.75 to 5.25 V
|
G34-30 (S5-4) - G34-14 (GND)
| R - W-B
| Power supply for solar sensor
| Ignition switch off
| Below 1 V
|
G34-33 (TS) - G34-14 (GND)
| V - W-B
| Solar sensor signal
| - Ignition switch ON (IG)
- Solar sensor subjected to electric light
| 0.8 to 4.3 V
|
G34-33 (TS) - G34-14 (GND)
| V - W-B
| Solar sensor signal
| - Ignition switch ON (IG)
- Solar sensor covered with a cloth
| Below 0.8 V
|
G34-34 (SG-1) - Body ground
| SB - Body ground
| Ground for room temperature sensor
| Always
| Below 1 V
|
G34-37 (LIN1) - G34-14 (GND)
| LG - W-B
| LIN communication signal
| Ignition switch ON (IG)
| Pulse generation
|
G34-39 (PTC2) - G34-14 (GND)*1
| BR - W-B
| Quick heater operation signal
| - Ignition switch ON (READY)
- ECO mode switch (eco switch assembly) off
- Blower motor on
- Temperature settings: MAX HOT
- Engine coolant temperature approximately 50°C lower
- Ambient temperature 10°C or lower
- IDH terminal signal less than 1 V (Inverter with converter assembly overload not detected)
| Below 1 V
|
G34-40 (PTC1) - G34-14 (GND)*1
| V - W-B
| Quick heater operation signal
| - Ignition switch ON (READY)
- ECO mode switch (eco switch assembly) off
- Blower motor on
- Temperature settings: MAX HOT
- Engine coolant temperature approximately 50°C or lower
- Ambient temperature 10°C or lower
- IDH terminal signal less than 1 V (Inverter with converter assembly overload not detected)
| Below 1 V
|
z1-2 (BUS G) - Body ground
| -
| Ground for BUS IC
| Always
| Below 1 V
|
z1-3 (BUS) - z1-2 (BUS G)
| -
| BUS IC control signal
| Ignition switch ON (IG)
| Pulse generation
|
z1-4 (B BUS) - z1-2 (BUS G)
| -
| Power supply for BUS IC
| Ignition switch off
| 11 to 14 V
|
z1-5 (SGA) - Body ground
| -
| Ground for evaporator temperature sensor
| Always
| Below 1 V
|
z1-6 (TEA) - z1-5 (SGA)
| -
| Evaporator temperature sensor signal
| - Ignition switch ON (IG)
- Evaporator temperature: 0°C (32°F)
| 2.0 to 2.4 V
|
z1-6 (TEA) - z1-5 (SGA)
| -
| Evaporator temperature sensor signal
| - Ignition switch ON (IG)
- Evaporator temperature: 15°C (59°F)
| 1.4 to 1.8 V
|