Home › Engine / Hybrid System › 1NZ-FXE COOLING › EXHAUST PIPE GAS CONTROL ACTUATOR

EXHAUST PIPE GAS CONTROL ACTUATOR > REMOVAL

for Preparation Click here



1. REMOVE FRONT EXHAUST PIPE ASSEMBLY
(Click here)


2. DRAIN COOLANT (for Engine)

NOTICE:
Do not remove the water filler cap sub-assembly, engine drain cock plug or radiator drain cock plug while the engine and radiator are still hot. Pressurized, hot engine coolant and steam may be released and cause serious burns.

  1. Loosen the radiator drain cock plug.



  1. Remove the water filler cap sub-assembly and drain the coolant.


    A267952E01


    Text in Illustration 
    *1
    Water Filler Cap Sub-assembly
    *2
    Radiator Drain Cock Plug
    *3
    Engine Drain Cock Plug
    *4
    Water Filler

    HINT:
    Collect the coolant in a container and dispose of it according to the regulations in your area.



    A267960
  1. Remove the stop ring.



    A268695E01
  1. Connect the hose to the engine drain cock plug.
    Text in Illustration 
    *1
    Hose

  1. Pull out the engine drain cock plug and drain the coolant.



3. REMOVE EXHAUST PIPE GAS CONTROL ACTUATOR SUB-ASSEMBLY


    A279077
  1. Remove the 5 bolts, No. 1 exhaust pipe heat insulator and exhaust pipe gas control actuator sub-assembly with the exhaust by-pass pipe installed.

    NOTICE:
    1. When removing the exhaust pipe gas control actuator sub-assembly, use caution because coolant may spill out from the exhaust heat recirculation system.
    2. Do not apply any excessive force to the exhaust by-pass pipe when removing the exhaust pipe gas control actuator sub-assembly.

  1. Remove the exhaust by-pass pipe from the exhaust pipe gas control actuator sub-assembly.