EXHAUST PIPE GAS CONTROL ACTUATOR > REMOVAL |
| 1. REMOVE FRONT EXHAUST PIPE ASSEMBLY |
| 2. DRAIN COOLANT (for Engine) |
Loosen the radiator drain cock plug.
Remove the water filler cap sub-assembly and drain the coolant.

| *1 | Water Filler Cap Sub-assembly | *2 | Radiator Drain Cock Plug |
| *3 | Engine Drain Cock Plug | *4 | Water Filler |
![]() |
Remove the stop ring.
![]() |
Connect the hose to the engine drain cock plug.
| *1 | Hose |
Pull out the engine drain cock plug and drain the coolant.
| 3. REMOVE EXHAUST PIPE GAS CONTROL ACTUATOR SUB-ASSEMBLY |
![]() |
Remove the 5 bolts, No. 1 exhaust pipe heat insulator and exhaust pipe gas control actuator sub-assembly with the exhaust by-pass pipe installed.
Remove the exhaust by-pass pipe from the exhaust pipe gas control actuator sub-assembly.