METER / GAUGE SYSTEM > Odo/Trip Switch Malfunction |

| 1.INSPECT TRIP SWITCH |
![]() |
Remove the trip switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (CS) - 12 (E) | Unit change switch pressed | Below 1 Ω |
| 1 (CS) - 12 (E) | Unit change switch not pressed | 10 kΩ or higher |
| 9 (HOUR) - 12 (E) | Hour adjust switch pressed | Below 1 Ω |
| 9 (HOUR) - 12 (E) | Hour adjust switch not pressed | 10 kΩ or higher |
| 10 (MIN) - 12 (E) | Minute adjust switch pressed | Below 1 Ω |
| 10 (MIN) - 12 (E) | Minute adjust switch not pressed | 10 kΩ or higher |
| 11 (RST) - 12 (E) | Set switch pressed | Below 1 Ω |
| 11 (RST) - 12 (E) | Set switch not pressed | 10 kΩ or higher |
| *1 | Trip Switch (for RHD) |
| *2 | Trip Switch (for LHD) |
| *1 | Component without harness connected (Trip Switch) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (NO. 3 METER CIRCUIT PLATE - TRIP SWITCH) |
Disconnect the L27 and L57 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L27-2 (TC O) - L57-1 (CS) | Always | Below 1 Ω |
| L27-2 (TC O) - Body ground | Always | 10 kΩ or higher |
| L27-12 (HOUR) - L57-9 (HOUR) | Always | Below 1 Ω |
| L27-12 (HOUR) - Body ground | Always | 10 kΩ or higher |
| L27-13 (MIN) - L57-10 (MIN) | Always | Below 1 Ω |
| L27-13 (MIN) - Body ground | Always | 10 kΩ or higher |
| L27-17 (RST) - L57-11 (RST) | Always | Below 1 Ω |
| L27-17 (RST) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||