Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A7A-122    Generator Inverter Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter, .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A7A
122
Generator inverter fail signal detection (overcurrent due to system malfunction)
A malfunction is detected in any of the generator components (generator inverter, generator, MG ECU, etc.).
(1 trip detection logic)
  1. Power management control ECU
  2. Inverter with converter assembly
  3. Hybrid vehicle generator assembly
  4. Hybrid vehicle motor assembly
  5. Generator cable
  6. Motor cable
  7. Wire harness or connector
  8. PCU fuse

MONITOR DESCRIPTION

If too much current is detected flowing through the generator inverter, the generator inverter transmits an inverter fail signal to the MG ECU. Upon receiving this signal, the power management control ECU (HV CPU) will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A7A (INF 122): GFIV detection (Over current malfunction)
Required sensors / components
Generator inverter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU (HV CPU)
DTC P0A7A (INF 122) is not detected

CONFIRMATION DRIVING PATTERN


A308311E01

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 30 seconds or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. Turn the power switch on (READY).
  7. With park (P) selected, wait for 5 seconds. [A]

    HINT:
    Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc.)

  8. Drive the vehicle approximately 10 minutes mainly using the engine. [B]
  9. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
  10. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.

  11. Check that permanent DTCs are cleared.
  12. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 .
Refer to the wiring diagram for DTC P324E-788 .
Refer to the wiring diagram for DTC U0110-159 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 5 seconds or more.
  2. Drive the vehicle for approximately 10 minutes mainly using the engine.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A7A-122 is set before any of the DTCs in the table below are set
    A
    Any of the DTCs including pending DTCs in the table 1 below are set before P0A7A-122 is set
    B
    Any of the DTCs including pending DTCs in the table 2 below are set before P0A7A-122 is set
    C


    Table 1 
    DTC No.
    Relevant Diagnosis
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P3004-803
    High Voltage Power Resource

    Table 2 
    DTC No.
    Relevant Diagnosis
    P3011-123, P3012-123, P3013-123, P3014-123, P3015-123, P3016-123, P3017-123, P3018-123, P3019-123, P3020-123, P3021-123, P3022-123, P3023-123, P3024-123
    Battery Block # Becomes Weak
    P0AFC-123
    Hybrid Battery Pack Sensor Module
    P308A-123
    Hybrid Battery Voltage Sensor All Circuits Low
    P0AC0-123
    Hybrid Battery Pack Current Sensor Circuit Range/Performance
    P0AC1-123
    Hybrid Battery Pack Current Sensor Circuit Low
    P0AC2-123
    Hybrid Battery Pack Current Sensor Circuit High
    P0A9C-123
    Hybrid Battery Temperature Sensor "A" Range/Performance
    P0A9D-123
    Hybrid Battery Temperature Sensor "A" Circuit Low
    P0A9E-123
    Hybrid Battery Temperature Sensor "A" Circuit High
    P0AC6-123
    Hybrid Battery Temperature Sensor "B" Range/Performance
    P0AC7-123
    Hybrid Battery Temperature Sensor "B" Circuit Low
    P0AC8-123
    Hybrid Battery Temperature Sensor "B" Circuit High
    P0ACB-123
    Hybrid Battery Temperature Sensor "C" Range/Performance
    P0ACC-123
    Hybrid Battery Temperature Sensor "C" Circuit Low
    P0ACD-123
    Hybrid Battery Temperature Sensor "C" Circuit High
    P3065-123
    Hybrid Battery Temperature Sensor Range/Performance Stuck "A"

    HINT:
    1. Refer to the Freeze Frame data to determine the order in which the DTCs were set.
    2. P0A7A-122 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)

C
GO TO DTC CHART (HYBRID BATTERY SYSTEM) (Click here)
A


2.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A7A-203 is not output
    A
    P0A7A-203 is also output
    B

    NOTICE:
    1. If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, return to perform troubleshooting for this DTC.
    2. Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnosis procedure.

  1. Turn the power switch off.



B
GO TO DTC CHART (P0A7A-203) (Click here)
A


3.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    HINT:
    1. If P0A7A-203 was not output in step 2 of this diagnosis procedure, check Table 1 below.
    2. If P0A7A-203 was output in step 2 of this diagnosis procedure, repair that DTC first, then check Table 2 below.

    Result:
    Result
    Proceed to
    P0A7A-122 only is output or the DTCs except in the following table are also output.
    A
    Any of the following DTCs including pending DTCs are also output.
    B


    Table 1 
    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes)*1
    Generator Control Module
    P0A1B (all INF codes)*1
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A60 (all INF codes)*1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes)*1
    Drive Motor "A" Phase W Current
    P0A72 (all INF codes)*1
    Generator Phase V Current
    P0A75 (all INF codes)*1
    Generator Phase W Current
    P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808
    Drive Motor "A" Inverter Performance
    P0A7A-325, 344, 517, 518, 809, 810, 811
    Generator Inverter Performance
    P0A90-509
    Drive Motor "A" Performance
    P0A92-521
    Hybrid Generator Performance
    P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590
    DC/DC Converter Performance
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P3004-803
    High Voltage Power Resource

    Table 2 
    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes)*1
    Generator Control Module
    P0A1B (all INF codes)*1
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A60 (all INF codes)*1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes)*1
    Drive Motor "A" Phase W Current
    P0A72-333
    Generator Phase V Current
    P0A75-341
    Generator Phase W Current
    P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808
    Drive Motor "A" Inverter Performance
    P0A7A-325, 517, 518, 809, 810, 811
    Generator Inverter Performance
    P0A90-509
    Drive Motor "A" Performance
    P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590
    DC/DC Converter Performance
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P3004-803
    High Voltage Power Resource

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0A7A-122 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
A214648

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

  1. Check the connection of the low voltage connector of the inverter with converter assembly.

    OK:
    The connector is connected securely and there are no contact problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


5.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.

  1. Turn the power switch on (IG).



    A217747E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-12 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-7 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-8 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-10 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-9 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the low voltage connector from the inverter with converter assembly.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK GENERATOR RESOLVER
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217747E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) - D29-12 (GRFG)
    Power switch off
    7.1 to 21.6 Ω
    D29-7 (GSN) - D29-8 (GSNG)
    Power switch off
    13.7 to 34.5 Ω
    D29-10 (GCS) - D29-9 (GCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-11 (GRF) or D29-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-7 (GSN) or D29-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-10 (GCS) or D29-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 19
OK


7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.

  1. Turn the power switch on (IG).



    A217747E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-2 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-3 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-4 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-6 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    D29-5 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.CHECK MOTOR RESOLVER
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217747E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) - D29-2 (MRFG)
    Power switch off
    7.1 to 21.6 Ω
    D29-3 (MSN) - D29-4 (MSNG)
    Power switch off
    13.7 to 34.5 Ω
    D29-6 (MCS) - D29-5 (MCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D29-1 (MRF) or D29-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-3 (MSN) or D29-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D29-6 (MCS) or D29-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 21
OK


9.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A209686
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A215643E02
  1. Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    8.0 N*m (82 kgf*cm, 71 in.*lbf)
    Bolt B:
    9.2 N*m (94 kgf*cm, 81 ft.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the generator cable from the inverter with converter assembly.

  1. Check for arc marks at the bolts for the generator cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the generator cable to the inverter with converter assembly.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


10.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A209686
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A215644E02
  1. Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    8.0 N*m (82 kgf*cm, 71 in.*lbf)
    Bolt B:
    9.2 N*m (94 kgf*cm, 81 ft.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt A is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

  1. Disconnect the motor cable from the inverter with converter assembly.

  1. Check for arc marks at the bolts for the motor cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable to the inverter with converter assembly.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


11.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A209686
  1. Remove the inverter terminal cover from the inverter with converter assembly.

  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.



    A215629E02
  1. Check generator for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the generator temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      f1-1 (W) - f1-2 (U)
      Power switch off
      89.5 to 98.9mΩ
      f1-2 (U) - f1-3 (V)
      Power switch off
      89.5 to 98.9mΩ
      f1-3 (V) - f1-1 (W)
      Power switch off
      89.5 to 98.9mΩ

      Text in Illustration 
      *1
      Generator Cable
      *2
      Shield Ground

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68° F (20°C).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 68° F (20°C) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (° C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-3 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the inverter terminal cover.



NG
Go to step 26
OK


12.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A209686
  1. Remove the inverter terminal cover from the inverter with converter assembly.

  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.



    A215630E01
  1. Check motor for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the motor temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      e1-1 (W) - e1-2 (U)
      Power switch off
      152.6 to 169.0 mΩ
      e1-2 (U) - e1-3 (V)
      Power switch off
      157.6 to 174.0 mΩ
      e1-3 (V) - e1-1 (W)
      Power switch off
      151.6 to 168.0 mΩ

      Text in Illustration 
      *1
      Motor Cable
      *2
      Shield Ground

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68° F (20°C).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 68° F (20°C) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (° C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    e1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    e1-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    e1-3 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the inverter terminal cover.



NG
Go to step 28
OK


13.CHECK FUSE (PCU)


    A216754E01
  1. Remove the PCU fuse from the engine room relay block and junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    PCU fuse terminal
    Always
    Below 1Ω

    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    PCU fuse

  1. Install the PCU fuse.



NG
Go to step 23
OK


14.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A59 from inverter with converter assembly.



    A215725E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A59-28 (GND1) - Body ground
    Power switch off
    Below 1 Ω
    A59-27 (GND2) - Body ground
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A59-10 (+B) - Body ground
    Power switch on (IG)
    Same as auxiliary battery voltage
    A59-9 (+B2) - Body ground
    Power switch on (IG)
    Same as auxiliary battery voltage

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE POWER SOURCE CIRCUIT
OK


15.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Turn the power switch off.

  1. Disconnect connector A59 from the inverter with converter assembly.

  1. Disconnect connector A22 from the power management control ECU.



    A216755E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    A22-24 (HTM+) - A59-8 (HTM+)
    Power switch off
    Below 1 Ω
    A22-25 (HTM-) - A59-18 (HTM-)
    Power switch off
    Below 1 Ω
    A22-30 (MTH+) - A59-7 (MTH+)
    Power switch off
    Below 1 Ω
    A22-29 (MTH-) - A59-17 (MTH-)
    Power switch off
    Below 1 Ω
    A22-33 (REQ+) - A59-6 (REQ+)
    Power switch off
    Below 1 Ω
    A22-32 (REQ-) - A59-16 (REQ-)
    Power switch off
    Below 1 Ω
    A22-21 (CLK+) - A59-5 (CLK+)
    Power switch off
    Below 1 Ω
    A22-20 (CLK-) - A59-15 (CLK-)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    A22-24 (HTM+) or A59-8 (HTM+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-25 (HTM-) or A59-18 (HTM-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-30 (MTH+) or A59-7 (MTH+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-29 (MTH-) or A59-17 (MTH-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-33 (REQ+) or A59-6 (REQ+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-32 (REQ-) or A59-16 (REQ-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-21 (CLK+) or A59-5 (CLK+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A22-20 (CLK-) or A59-15 (CLK-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *2
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A22-24 (HTM+) or A59-8 (HTM+) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-25 (HTM-) or A59-18 (HTM-) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-30 (MTH+) or A59-7 (MTH+) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-29 (MTH-) or A59-17 (MTH-) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-33 (REQ+) or A59-6 (REQ+) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-32 (REQ-) or A59-16 (REQ-) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-21 (CLK+) or A59-5 (CLK+) - Body ground
    Power switch on (IG)
    Below 1 V
    A22-20 (CLK-) or A59-15 (CLK-) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Connect the power management control ECU connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


16.CHECK POWER MANAGEMENT CONTROL ECU
  1. Disconnect connector A59 from the inverter with converter assembly.

  1. Disconnect connector A22 from the power management control ECU.



    A234460E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A22-24 (HTM+) - A22-25 (HTM-)
    Power switch off
    80 to 170 Ω
    A22-30 (MTH+) - A22-29 (MTH-)
    Power switch off
    80 to 170 Ω
    A22-33 (REQ+) - A22-32 (REQ-)
    Power switch off
    80 to 170 Ω
    A22-21 (CLK+) - A22-20 (CLK-)
    Power switch off
    80 to 170 Ω

    Text in Illustration 
    *1
    Component without harness connected
    (Power Management Control ECU)

  1. Connect the power management control ECU connector.

  1. Connect the inverter with converter assembly connector.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK


17.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A240800
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


18.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A217043
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

19.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A240800
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


20.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217748E01
  1. Disconnect the generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D7-1 (GRF) - D29-11 (GRF)
    Power switch off
    Below 1 Ω
    D7-5 (GRFG) - D29-12 (GRFG)
    Power switch off
    Below 1 Ω
    D7-2 (GSN) - D29-7 (GSN)
    Power switch off
    Below 1 Ω
    D7-6 (GSNG) - D29-8 (GSNG)
    Power switch off
    Below 1 Ω
    D7-3 (GCS) - D29-10 (GCS)
    Power switch off
    Below 1 Ω
    D7-7 (GCSG) - D29-9 (GCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D7-1 (GRF) or D29-11 (GRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-5 (GRFG) or D29-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-2 (GSN) or D29-7 (GSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-6 (GSNG) or D29-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-3 (GCS) or D29-10 (GCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D7-7 (GCSG) or D29-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Generator Resolver)
    *2
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    HINT:
    The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the generator resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY (Click here)  

21.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A217043
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


22.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
  1. Disconnect the low voltage connector D29 from the inverter with converter assembly.



    A217749E01
  1. Disconnect the motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    D1-3 (MRF) - D29-1 (MRF)
    Power switch off
    Below 1 Ω
    D1-6 (MRFG) - D29-2 (MRFG)
    Power switch off
    Below 1 Ω
    D1-1 (MSN) - D29-3 (MSN)
    Power switch off
    Below 1 Ω
    D1-4 (MSNG) - D29-4 (MSNG)
    Power switch off
    Below 1 Ω
    D1-2 (MCS) - D29-6 (MCS)
    Power switch off
    Below 1 Ω
    D1-5 (MCSG) - D29-5 (MCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    D1-3 (MRF) or D29-1 (MRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-6 (MRFG) or D29-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-1 (MSN) or D29-3 (MSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-4 (MSNG) or D29-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-2 (MCS) or D29-6 (MCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    D1-5 (MCSG) or D29-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Motor Resolver)
    *2
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    HINT:
    The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the motor resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE MOTOR ASSEMBLY (Click here)  

23.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A59 from the inverter with converter assembly.



    A215725E09
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A59-10 (+B) - Body ground
    Power switch off
    10 kΩ or higher
    A59-9 (+B2) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 25
OK


24.REPLACE INVERTER WITH CONVERTER ASSEMBLY
  1. Replace the inverter with converter assembly (Click here).


NEXT

REPLACE FUSE (PCU) 

25.REPAIR OR REPLACE HARNESS OR CONNECTOR
  1. Repair or replace the wire harness or connector.


NEXT

REPLACE FUSE (PCU) 

26.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter with converter assembly.



    A217462E01
  1. Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=20 N*m {204 kgf*cm, 15 ft.*lbf}
    Bolt B:
    T=10 N*m {102 kgf*cm, 7 ft.*lbf}

    NOTICE:
    1. Make sure that the tightening torque of the bolt A is between 16 and 24 N*m (163 and 245 kgf*cm, 12 and 18 ft.*lbf).
    2. Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

  1. Disconnect the generator cable from the hybrid vehicle transaxle assembly.

  1. Check for arc marks at the bolts for the generator cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the generator cable to the hybrid vehicle transaxle assembly.

  1. Install the inverter with converter assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


27.CHECK GENERATOR CABLE

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the generator cable.



    A217727E01
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-3 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Generator Cable
    (Inverter with Converter Assembly Side)
    *2
    Shield ground
    *3
    Generator Cable
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f1-1 (W) - f2-3 (W)
    Power switch off
    Below 1 Ω
    f1-2 (U) - f2-2 (U)
    Power switch off
    Below 1 Ω
    f1-3 (V) - f2-1 (V)
    Power switch off
    Below 1 Ω
    f1-1 (W) - f2-2 (U)
    Power switch off
    100 MΩ or higher
    f1-2 (U) - f2-1 (V)
    Power switch off
    100 MΩ or higher
    f1-3 (V) - f2-3 (W)
    Power switch off
    100 MΩ or higher

  1. Install the generator cable.



NG
REPLACE GENERATOR CABLE (Click here)
OK

REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY (Click here)  

28.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A217463
  1. Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

    Specified Condition:
    T=10 N*m {102 kgf*cm, 7 ft.*lbf}

    NOTICE:
    Make sure that the tightening torque of the bolts is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

  1. Disconnect the motor cable from the hybrid vehicle transaxle assembly.

  1. Check for arc marks at the bolts for the motor cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable to the hybrid vehicle transaxle assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


29.CHECK MOTOR CABLE

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the motor cable.



    A217728E01
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    e1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    e1-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    e1-3 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Motor Cable
    (Inverter with Converter Assembly Side)
    *2
    Shield ground
    *3
    Motor Cable
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    e1-1 (W) - e2-1 (W)
    Power switch off
    Below 1 Ω
    e1-2 (U) - e2-3 (U)
    Power switch off
    Below 1 Ω
    e1-3 (V) - e2-2 (V)
    Power switch off
    Below 1 Ω
    e1-1 (W) - e2-3 (U)
    Power switch off
    100 MΩ or higher
    e1-2 (U) - e2-2 (V)
    Power switch off
    100 MΩ or higher
    e1-3 (V) - e2-1 (W)
    Power switch off
    100 MΩ or higher

  1. Install the motor cable.



NG
REPLACE MOTOR CABLE (Click here)
OK

REPLACE HYBRID VEHICLE MOTOR ASSEMBLY (Click here)