Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0A85-123    Hybrid Battery Pack Cooling Fan 1

for Preparation Click here


DESCRIPTION

Refer to the circuit description for DTC P0A84-123 .

DTC No.
DTC Detection Condition
Trouble Area
P0A85-123
Both of the following conditions are met due to the battery cooling blower system malfunction:
(1 trip detection logic)
  1. The speed calculated based on the battery cooling blower assembly output voltage (VM) is not within the target control speed range.
  2. The battery cooling blower assembly speed is excessively high when a speed below a certain level is requested.
  1. Wire harness or connector
  2. Battery cooling blower assembly
  3. Battery smart unit
  4. Hybrid battery thermistor

Related Data List 
DTC No.
Data List
P0A85-123
  1. Cooling Fan 0
  2. Cooling Fan Mode 1
The following items can be helpful when performing repairs:
Data List
  1. Temp of Batt TB1 to 3
  2. +B

HINT:
If the battery cooling blower assembly speed is too high, this DTC is stored.


WIRING DIAGRAM


A231484E12


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After the power switch is turned off, the display and navigation module display (HDD navigation system) records various types of memory and settings. As a result, after turning the power switch off, make sure to wait at least 60 seconds before disconnecting the cable from the negative (-) battery terminal.

HINT:
  1. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
    4. Select fan mode 6 and operate the battery cooling blower assembly.
  2. Operation of the battery cooling blower can be confirmed by checking if air is sucked into the air intake port of the intake duct.

1.CHECK FOR DTCS (DTC P0AFC-123 IS OUTPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check and record any HV system DTCs, INF codes and freeze frame data.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Disconnect the Techstream from the DLC3.



B
GO TO DTC CHART
A


2.CHECK HARNESS AND CONNECTOR (VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

    NOTICE:
    If the active test cannot be performed, skip it and proceed to the next step to check voltage. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E07
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    S14-2 (VM0) - S14-4 (GND0)
    Battery cooling blower is operating
    Below 5 V

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

HINT:
Measure the voltage on the wire side of the connector that is part of the battery cooling blower.

  1. Turn the power switch off.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
Go to step 6
OK


3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.



    A217836E03
  1. Disconnect connector c1 from the battery smart unit.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery cooling blower assembly connector and battery smart unit connector are not loose or disconnected.



    A217837E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) - c1-7 (VM)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) or c1-7 (VM) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the S14 connector of battery cooling blower assembly.

  1. Connect the c1 connector of the battery smart unit.

  1. Install the hybrid battery junction block assembly (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HYBRID BATTERY THERMISTOR (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A217836E01
  1. Disconnect connectors c1 and z17 from the battery smart unit.

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.



    A216735E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    z17-6 (TBO) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-12 (GBO) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-5 (TB1) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-11 (GB1) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-4 (TB2) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-10 (GB2) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-1 (TCO) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher
    z17-7 (GCO) - c1-4 (IGCT)
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the battery smart unit connectors.

  1. Install the hybrid battery junction block assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
Go to step 5
OK

REPLACE BATTERY SMART UNIT (Click here)  

5.CHECK HARNESS AND CONNECTOR (INLET AIR TEMPERATURE SENSOR AND BATTERY TEMPERATURE SENSOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the upper hybrid battery cover sub-assembly (Click here).

  1. Check the wire harness and connectors of the battery temperature sensor and inlet air temperature sensor for abnormalities by sight and touch.

    Specified Condition:
    There are no open or short circuits in the wire harness and connectors. There are no short circuits to other wire harnesses.

  1. Install the upper hybrid battery cover sub-assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR HARNESS OR CONNECTOR
OK

REPLACE HYBRID BATTERY THERMISTOR (Click here)  

6.CHECK HARNESS AND CONNECTOR (VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.

  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the power switch on (IG).



    A190228E07
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) - S14-4 (GND0)
    Power switch on (IG)
    Below 5 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)

    NOTICE:
    If the power switch is turned on (IG) with the battery cooling blower assembly connector disconnected, DTC P0A84-123 will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Connect the battery cooling blower assembly connector.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
Go to step 7
OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY (Click here)  

7.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery cooling blower assembly connector and battery smart unit connector are not loose or disconnected.



    A217836E03
  1. Disconnect connector c1 from the battery smart unit.



    A217837E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) and c1-7 (VM) - Other terminal
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the battery smart unit connector.

  1. Connect the battery cooling blower assembly connector.

  1. Install the hybrid battery junction block assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BATTERY SMART UNIT (Click here)