Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM

CAN COMMUNICATION SYSTEM > Power Management Control ECU Communication Stop Mode

for Preparation Click here


DESCRIPTION


Detection Item
Symptom
Trouble Area
Power Management Control ECU Communication Stop Mode
  1. "Electric Power Control" is not displayed on the CAN Bus Check screen of the Techstream.
  2. Applies to Power Management Control ECU Communication Stop Mode in DTC Combination Table.
  1. Power management control ECU branch wire or connector
  2. Power source circuit of power management control ECU
  3. Power management control ECU

WIRING DIAGRAM


C210479E14


INSPECTION PROCEDURE

NOTICE:
  1. Turn the power switch off before measuring the resistances between CAN bus main wires and between CAN bus branch wires.
  2. Turn the power switch off before inspecting CAN bus wires for a ground short.
  3. After the power switch is turned off, check that the key reminder warning system and light reminder warning system are not operating.
  4. Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the power switch, any other switches or the doors. If any doors need to be opened in order to check connectors, open the doors and leave them open.

HINT:
  1. Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
  2. Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.

1.CHECK CAN BUS WIRE FOR DISCONNECTION (POWER MANAGEMENT CONTROL ECU BRANCH WIRE)
  1. Turn the power switch off.



    A204446E06
  1. Disconnect the power management control ECU connector.
    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Value
    L6-25 (CA1H) - L6-24 (CA1L)
    Power switch off
    54 to 69 Ω



NG
REPAIR OR REPLACE CAN NO. 1 BUS BRANCH WIRE OR CONNECTOR (POWER MANAGEMENT CONTROL ECU)
OK


2.CHECK HARNESS AND CONNECTOR (POWER SOURCE TERMINAL)


    A204441E18
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Value
    A21-2 (+B2) - Body Ground
    Always
    11 to 14 V
    A22-5 (+B1) - Body Ground
    Always
    11 to 14 V

    Text in Illustration 
    *1
    Component with harness connected
    (Power Management Control ECU)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE TERMINAL)
OK


3.CHECK HARNESS AND CONNECTOR (GROUND TERMINAL)


    A204441E19
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Value
    L5-6 (E1) - Body Ground
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Component with harness connected
    (Power Management Control ECU)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (GROUND TERMINAL)
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)