DTC U0164 Lost Communication with A/C ECU |
| DTC No. | DTC Detection Condition | Trouble Area |
| U0164 | No communication from the air conditioning amplifier continues. |
|

| 1.RECONFIRM DTC OUTPUT |
Reconfirm DTCs.
| Result | Proceed to |
| U1002 is not output from power management control ECU (Techstream display/Power Management2) | A |
| U1002 is output from power management control ECU (Techstream display/Power Management2) | B |
|
| ||||
| A | |
| 2.CHECK CAN BUS WIRE FOR DISCONNECTION (AIR CONDITIONING AMPLIFIER BRANCH WIRE) |
Turn the power switch off.
![]() |
Disconnect the air conditioning amplifier connector.
| *1 | Front view of wire harness connector (to Air Conditioning Amplifier) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L17-11 (CANH) - L17-12 (CANL) | Power switch off | 54 to 69 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (POWER SOURCE TERMINAL) |
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L17-1 (IG+) - Body ground | Power switch on (IG) | 11 to 14 V |
| *1 | Front view of wire harness connector (to Air Conditioning Amplifier) |
|
| ||||
| OK | |
| 4.CHECK FRONT AND SIDE MONITOR SYSTEM (GROUND TERMINAL) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L17-14 (GND) - Body ground | Always | Below 1 Ω |
| *1 | Front view of wire harness connector (to Air Conditioning Amplifier) |
|
| ||||
| OK | ||
| ||