DTC U1002 Lost Communication with Gateway Module (Power Management2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| U1002 | Power management control ECU cannot receive signals from all ECUs that have been memorized as those connected to the power management bus. |
|

| 1.CHECK CAN BUS WIRE |
Turn the power switch off.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | Result |
| L6-31 (CA3P) - L6-30 (CA3N) | Power switch off | 54 to 69 Ω | Below 54 Ω: Short circuit between bus lines |
| 70 Ω or higher: Open circuit in a main bus line | |||
| L6-31 (CA3P) - L6-5 (E02) | Power switch off | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L6-30 (CA3N) - L6-5 (E02) | Power switch off | 200 Ω or higher | Below 200 Ω: CANL ground short |
| *1 | Component with harness connected (Power Management Control ECU) |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
| L6-31 (CA3P) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L6-30 (CA3N) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result | Proceed to |
| OK | A |
| Open circuit in CAN main bus wire | B |
| Short circuit between bus lines | C |
| D |
|
| ||||
|
| ||||
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT |
Clear the DTCs.
Turn the power switch off.
Turn the power switch on (IG), recheck the DTC.
| Result | Proceed to |
| U1002 is output from power management control ECU (Techstream display/Power Management2) | A |
| Other DTC is output | B |
|
| ||||
| A | ||
| ||
| 3.CHECK FOR OPEN IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU) |
![]() |
Disconnect the power management control ECU connector.
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L6-31 (CA3P) - L6-30 (CA3N) | Power switch off | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||
| 4.CHECK FOR OPEN IN CAN BUS WIRE (ECM) |
Reconnect the power management control ECU connector.
![]() |
Disconnect the ECM connector.
| *1 | Front view of wire harness connector (to ECM) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A57-12 (CANP) - A57-4 (CANN) | Power switch off | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||
| 5.CHECK FOR OPEN IN CAN BUS WIRE (CAN NO. 4 J/C MAIN WIRE) |
Reconnect the ECM connector.
![]() |
Disconnect the CAN No. 4 junction connector.
| *1 | Front view of wire harness connector (to CAN No. 4 Junction Connector) |
| *2 | to Power Management Control ECU |
| *3 | to ECM |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | Connected to |
| L101-12 (CANH) - L101-1 (CANL) | Power switch off | 108 to 132 Ω | Power management control ECU |
| L101-15 (CANH) - L101-4 (CANL) | Power switch off | 108 to 132 Ω | ECM |
| Result | Proceed to |
| OK | A |
| NG (to power management ECU main wire) | B |
| NG (to ECM main wire) | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 6.CHECK FOR SHORT IN CAN BUS WIRES (POWER MANAGEMENT CONTROL ECU) |
![]() |
Disconnect the power management control ECU connector.
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L6-31 (CA3P) - L6-30 (CA3N) | Power switch off | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||
| 7.CHECK FOR SHORT IN CAN BUS WIRES (ECM) |
Reconnect the power management control ECU connector.
![]() |
Disconnect the ECM connector.
| *1 | Front view of wire harness connector (to ECM) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A57-12 (CANP) - A57-4 (CANN) | Power switch off | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||
| 8.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C MAIN WIRE) |
Reconnect the ECM connector.
![]() |
Disconnect the CAN No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | Connected to |
| L101-12 (CANH) - L101-1 (CANL) | Power switch off | 108 to 132 Ω | Power management control ECU |
| L101-15 (CANH) - L101-4 (CANL) | Power switch off | 108 to 132 Ω | ECM |
| *1 | Front view of wire harness connector (to CAN No. 4 Junction Connector) |
| *2 | to Power Management Control ECU |
| *3 | to ECM |
| Result | Proceed to |
| OK | A |
| NG (to Power management ECU main wire) | B |
| NG (to ECM main wire) | C |
|
| ||||
|
| ||||
| A | |
| 9.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C - SKID CONTROL ECU) |
Disconnect the skid control ECU (brake booster with master cylinder) connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L101-14 (CANH) - L101-3 (CANL) | Power switch off | 1 MΩ or higher |
| *1 | Front view of wire harness connector (to CAN No. 4 Junction Connector) |
| *2 | to Skid Control ECU |
|
| ||||
| OK | |
| 10.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C - A/C ECU) |
Disconnect the air conditioning amplifier connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L101-13 (CANH) - L101-2 (CANL) | Power switch off | 1 MΩ or higher |
| *1 | Front view of wire harness connector (to CAN No. 4 Junction Connector) |
| *2 | to Air Conditioning Amplifier |
|
| ||||
| OK | |
| 11.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C) |
Reconnect the CAN No. 4 junction connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L6-31 (CA3P) - L6-30 (CA3N) | Power switch off | 108 to 132 Ω |
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
|
| ||||
| OK | |
| 12.CHECK FOR SHORT IN CAN BUS WIRES (AIR CONDITIONING AMPLIFIER) |
Reconnect the air conditioning amplifier connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| L6-31 (CA3P) - L6-30 (CA3N) | Power switch off | 108 to 132 Ω |
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
|
| ||||
| OK | ||
| ||
| 13.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C) |
Disconnect the CAN No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.

| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
| L101-12 (CANH) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANH ground short | Power management control ECU |
| L101-1 (CANL) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANL ground short | |
| L101-13 (CANH) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANH ground short | Air conditioning amplifier |
| L101-2 (CANL) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANL ground short | |
| L101-14 (CANH) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANH ground short | Skid control ECU |
| L101-3 (CANL) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANL ground short | |
| L101-15 (CANH) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANH ground short | ECM |
| L101-4 (CANL) - L61-4 (CG) | Power switch off | 200 Ω or higher | Inspection for CANL ground short | |
| L101-12 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Power management control ECU |
| L101-1 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| L101-13 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Air conditioning amplifier |
| L101-2 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| L101-14 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Skid control ECU |
| L101-3 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| L101-15 (CANH) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANH +B short | ECM |
| L101-4 (CANL) - L61-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| *1 | Front view of wire harness connector (to CAN No. 4 Junction Connector) | *2 | DLC3 |
| *3 | to Power Management Control ECU | *4 | to Air Conditioning Amplifier |
| *5 | to Skid Control ECU | *6 | to ECM |
|
| ||||
| OK | ||
| ||
| 14.CHECK FOR SHORT IN CAN BUS WIRES (ECU) |
Disconnect the connector that includes terminals CANH and CANL from the ECU to which the bus wire shorted to B+ or shorted to GND is connected (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | Purpose |
| L6-31 (CA3P) - L6-5 (E02) | Power switch off | 200 Ω or higher | Below 200 Ω: CANH ground short |
| L6-30 (CA3N) - L6-5 (E02) | Power switch off | 200 Ω or higher | Below 200 Ω: CANL ground short |
| L6-31 (CA3P) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| L6-30 (CA3N) - L6-7 (AM21) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| *1 | Component with harness connected (Power Management Control ECU) |
|
| ||||
| OK | ||
| ||