HYBRID CONTROL SYSTEM > Pattern Select Switch Eco Mode Circuit |

| 1.READ VALUE USING TECHSTREAM (CAN BUS CHECK) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: System Select / CAN Bus Check.
| Result | Proceed to |
| All of the ECUs and sensors that are currently connected to the CAN communication system are displayed. | A |
| None of the ECUs and sensors that are currently connected to the CAN communication system are displayed, or some of them are not displayed. | B |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HEALTH CHECK) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: System Select / Health Check.
Check DTCs.
| Result | Proceed to |
| No DTCs are output. | A |
| DTCs are output. | B |
Turn the power switch off.
|
| ||||
| A | |
| 3.PERFORM ACTIVE TEST USING TECHSTREAM (COMBINATION METER) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Body Electrical / Combination Meter / Active Test / Indicat. ECO Mode.
Perform the "Indicat. ECO Mode" Active Test.
| Tester Display | Description | Inspection Condition | Specified Condition |
| Indicat. ECO Mode | ECO mode indicator light | ECO mode | Comes on |
| Result | Proceed to |
| The ECO mode indicator light comes on | A |
| The ECO mode indicator light does not come on | B |
|
| ||||
| A | |
| 4.READ VALUE USING TECHSTREAM (ECO SWITCH) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Body Electrical / Air Conditioning / Data List / ECO Switch.
Read the value displayed on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| ECO Switch | ECO MODE switch condition/ ON or OFF | ECO MODE switch ON: ON ECO MODE switch OFF: OFF | - |
| Result | Proceed to |
| The Techstream display changes according to the ECO MODE switch operation. | A |
| The Techstream display does not changes according to the ECO MODE switch operation. | B |
|
| ||||
| A | ||
| ||
| 5.INSPECT INTEGRATION CONTROL AND PANEL SUB-ASSEMBLY (ECO MODE SWITCH) |
Remove the integration control and panel sub-assembly (ECO MODE switch).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L78-2 (ECU) - L78-5 (E) | ECO MODE Switch ON | Below 1 Ω |
| L78-2 (ECU) - L78-5 (E) | ECO MODE Switch OFF | 10 kΩ or higher |
| *1 | Component without harness connected (Integration Control and Panel Sub-assembly (ECO MODE Switch)) |
Install the integration control and panel sub-assembly.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (ECO MODE SWITCH - BODY GROUND) |
Disconnect connector L78 from the integration control and panel sub-assembly (ECO MODE switch).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L78-5 (E) - Body ground | Always | Below 1 Ω |
| *1 | Front view of wire harness connector (to Integration Control and Panel Sub-assembly (ECO MODE Switch)) |
Connect the integration control and panel sub-assembly connector.
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (ECO MODE SWITCH - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect connector L78 from the integration control and panel sub-assembly (ECO MODE switch).
Disconnect connector L17 from the air conditioning amplifier assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L78-2 (ECU) - L17-15 (ECOS) | Always | Below 1 Ω |
| L78-2 (ECU) or L17-15 (ECOS) - Body ground | Always | 10 kΩ or higher |
| *1 | Front view of wire harness connector (to Integration Control and Panel Sub-assembly (ECO MODE Switch)) |
| *2 | Rear view of wire harness connector (to Air Conditioning Amplifier Assembly) |
Connect the air conditioning amplifier assembly connector.
Connect the integration control and panel sub-assembly connector.
|
| ||||
| OK | ||
| ||