Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY

INTEGRATION RELAY > REMOVAL

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



2. REMOVE NO. 1 RELAY BLOCK COVER


    E189815
  1. Disengage the 3 claws and remove the No. 1 relay block cover.



3. REMOVE NO. 1 INTEGRATION RELAY


    E189816
  1. Disengage the 2 claws and pull up the No. 1 integration relay as shown in the illustration.



    E189817
  1. Disconnect the 3 connectors and remove the No. 1 integration relay.