INTEGRATION RELAY > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE NO. 1 RELAY BLOCK COVER |
![]() |
Disengage the 3 claws and remove the No. 1 relay block cover.
| 3. REMOVE NO. 1 INTEGRATION RELAY |
![]() |
Disengage the 2 claws and pull up the No. 1 integration relay as shown in the illustration.
![]() |
Disconnect the 3 connectors and remove the No. 1 integration relay.