DTC P0443 Evaporative Emission Control System Purge Control Valve Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0443 | Both of the following conditions (a) and (b) are met (1 trip detection logic): (a) The target control value and actual control value do not match for 10 seconds or more. (b) The target control value and actual control value do not match for 80 times or more. |
|

| Tester Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE VSV FOR EVAP CONTROL) |
![]() |
Disconnect the fuel vapor feed hose (on the canister side) of the purge VSV.
| *1 | Purge VSV |
| *2 | Fuel Vapor Feed Hose (to Canister) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the tester on.
Put the engine in inspection mode (maintenance mode) (Click here).
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for EVAP Control.
Operate the purge VSV and check the air flow.
| Activate the VSV for Evap Control | Specified Condition |
| ON | Air flows |
| OFF | Air does not flow |
| Result | Proceed to |
| Abnormal | A |
| Normal | B |
|
| ||||
| A | |
| 2.INSPECT PURGE VSV |
Inspect the purge VSV (Click here).
|
| ||||
| OK | |
| 3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF PURGE VSV) |
![]() |
Disconnect the purge VSV connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C19-1 - Body ground | Power switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector (to Purge VSV) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM) |
Disconnect the purge VSV connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C19-2 - C10-76 (PRG) | Always | Below 1 Ω |
| C19-2 or C10-76 (PRG) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| C19-2 - C9-76 (PRG) | Always | Below 1 Ω |
| C19-2 or C9-76 (PRG) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (PURGE VSV - NO. 1 INTEGRATION RELAY) |
Disconnect the purge VSV connector.
Remove the No. 1 integration relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C19-1 - 2C-4 | Always | Below 1 Ω |
| C19-1 or 2C-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||