DTC P0A08-264 DC / DC Converter Status Circuit |

| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A08 | 264 | The DC/DC converter is malfunctioning (charging has stopped) and the auxiliary battery voltage drops to 11 V or less. (1 trip detection logic) The DC/DC converter is malfunctioning for 120 seconds and the inverter coolant water temperature is 70°C or lower. (1 trip detection logic) |
|

| Malfunction Case | Remarks | Inspection Step |
| Fuse is blown. (DC/DC) | - | 4 |
| High-voltage insulation between the inverter, generator (MG1), motor (MG2) and body ground is poor (body ground). | DTC P0AA6 may be stored if the ground potential fluctuates due to a high-voltage insulation malfunction. | 1 |
| A signal connector of the hybrid vehicle control ECU or inverter is not connected securely. | - | 2. 3 |
| The DC/DC converter is malfunctioning. | Inspect the DC/DC converter function. | 9 |
| Control is suspended due to overheating. (The inverter water pump assembly is malfunctioning, the coolant is not sufficient, a hose is clogged, etc.) | When the inverter is overheating, the DC/DC converter has self protection control that suspends the DC/DC converter control. As that time, this DTC may be stored. The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off. | 10 to 13, 17 |
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A08-264 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1B-547 | Drive Motor "A" Control Module |
| P0A40-549 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A78-548 | Drive Motor "A" Inverter Performance |
| P0A93-346 | Inverter Cooling System Performance |
| P0AA6-526, 613 | Hybrid Battery Voltage System Isolation Fault |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P3004-131, 803 | High Voltage Power Resource |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors (Click here).
| *A | for LHD |
| *B | for RHD |
|
| ||||
| OK | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | |
| 4.CHECK FUSIBLE LINK (DC/DC) |
Disconnect connector 1E from the engine room relay block and junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1E-1 - 1D-1 (AMD) | Always | Below 1 Ω |
Check the fusible link (DC/DC) in the engine room relay block and junction block assembly for improper installation.
Connect the 1E connector to the engine room relay block and junction block assembly.
|
| ||||
| OK | |
| 5.CHECK CABLE AND WIRE HARNESS |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a4-1 (W) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| *1 | Motor Cable (for MG1) |
| *2 | Motor Cable (for MG2) |
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 6.CHECK AMD TERMINAL VOLTAGE (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY) |
Connect the cable to the negative (-) auxiliary battery terminal.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1D-1 (AMD) - Body ground | Power switch off | Same as auxiliary battery voltage |
Disconnect the cable from the negative (-) auxiliary battery terminal.
|
| ||||
| OK | |
| 7.CHECK AMD TERMINAL CONNECTION CONDITION |
Check that the service plug grip is not installed.
![]() |
Check that the bolt for the AMD terminal is tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.
| Result | Proceed to | |
| There are no arc marks. | The terminal is connected securely and there is no contact problem. | A |
| There are no arc marks. | The terminal is not connected securely and there is a contact problem. | B |
| There are arc marks. | - | C |
|
| ||||
|
| ||||
| A | |
| 8.CHECK HARNESS AND CONNECTOR (RESISTANCE VALUE OF NODD INSIDE HYBRID VEHICLE CONTROL ECU) |
Check that the service plug grip is not installed.
Disconnect connector A47 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A47-12 (NODD) - Body ground | Power switch off | 110 to 150 kΩ |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 9.CHECK DC/DC CONVERTER FUNCTION |
![]() |
Connect the AC/DC 400 A probe to the positive auxiliary battery line.
Install the service plug grip.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
![]() |
Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.
| Item | Condition | Specified Condition |
| Current flowing from auxiliary battery | Power switch on (READY) (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) | 0 A or less (no current from auxiliary battery) |
Measure the voltage according to the value(s) in the table below.
| Item | Condition | Specified Condition |
| Auxiliary battery voltage | Power switch on (READY) (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) | 13 to 15 V |
Turn the power switch off.
|
| ||||
| OK | |
| 10.CHECK QUANTITY OF HV COOLANT |
Check the HV coolant level in the inverter reserve tank.
Check for HV coolant leaks.
| Result | Proceed to |
| No leaks are found and coolant level in the inverter reserve tank assembly is above the low line. | A |
| No leaks are found and coolant level in the inverter reserve tank assembly is below the low line. | B |
| Coolant leaks are evident. | C |
|
| ||||
|
| ||||
| A | |
| Go to step 1 |
| 11.CHECK COOLANT HOSE |
Check if the hoses of the cooling system are kinked or clogged.
|
| ||||
| OK | |
| 12.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE ELECTRIC COOLING FAN) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" Active Test.
Turn the power switch off.
|
| ||||
| OK | |
| 13.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data Ambient Temperature using the intelligent tester.
Check if the freeze frame data Ambient Temperature is below freezing.
| Result | Proceed to |
| Ambient Temperature value is above freezing temperature of the HV coolant. | A |
| Ambient Temperature value is below freezing temperature of the HV coolant. | B |
Turn the power switch off.
|
| ||||
| A | ||
| ||
| 14.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable (for MG1) from the inverter with converter assembly.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield Ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
Connect the motor cable (for MG1).
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 15.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Disconnect the motor cable (for MG2) from the inverter with converter assembly.
![]() |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield Ground |
| *a | Motor Cable (for MG2) (Inverter with Converter Assembly Side) |
Connect the motor cable (for MG2).
Install the inverter terminal cover.
|
| ||||
| OK | ||
| ||
| 16.INSPECT HYBRID VEHICLE CONTROL ECU (RESISTANCE VALUE OF NODD INSIDE HYBRID VEHICLE CONTROL ECU) |
![]() |
Disconnect all the connectors from the hybrid vehicle control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A71-25 (NODD) - G80-6 (E1) | Power switch off | 110 to 150 kΩ |
| *a | Component without harness connected (Hybrid Vehicle Control ECU) |
Connect the hybrid vehicle control ECU connectors.
|
| ||||
| OK | ||
| ||
| 17.REPLACE HV COOLANT |
Replace the HV coolant with coolant having an appropriate concentration (appropriate freeze point) for the vehicle usage conditions (Click here).
| NEXT | ||
| ||
| 18.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the inverter with converter assembly (Click here).
![]() |
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
|
| ||||
|
| ||||
| A | |
| 19.CHECK MOTOR CABLE (FOR MG1) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG1) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a2-1 (W) - a1-1 (W) | Power switch off | Below 1 Ω |
| a2-2 (U) - a1-2 (U) | Power switch off | Below 1 Ω |
| a2-3 (V) - a1-3 (V) | Power switch off | Below 1 Ω |
| a2-1 (W) - a1-2 (U) | Power switch off | 100 MΩ or higher |
| a2-2 (U) - a1-3 (V) | Power switch off | 100 MΩ or higher |
| a2-3 (V) - a1-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | ||
| ||
| 20.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the hybrid vehicle transaxle assembly.
|
| ||||
|
| ||||
| A | |
| 21.CHECK MOTOR CABLE (FOR MG2) |
Check that the service plug grip is not installed.
Remove the motor cable (Click here).
![]() |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG2) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG2) (Hybrid Vehicle Transaxle Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a4-1 (W) - a3-1 (W) | Power switch off | Below 1 Ω |
| a4-2 (U) - a3-3 (U) | Power switch off | Below 1 Ω |
| a4-3 (V) - a3-2 (V) | Power switch off | Below 1 Ω |
| a4-1 (W) - a3-3 (U) | Power switch off | 100 MΩ or higher |
| a4-2 (U) - a3-2 (V) | Power switch off | 100 MΩ or higher |
| a4-3 (V) - a3-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
|
| ||||
| OK | ||
| ||